Schneider Electric Altivar 71 ATV71HU40N4 Variable Speed Drive With Heat Sink, 380/480 VAC, 11.5/14.1 A, 5 hp, 6.1 in W
AC Drives
402373
MFG #: ATV71HU40N4
Schneider Electric
2058.58000
/ ea
Schneider Electric ATV71HU40N4 SPEED DRIVE, 5HP, 460V, ATV71,3 phases,3-Phase,3-Phase,400/480VAC,4kW,Altivar 71,Altivar 71,IP20,Modbus-CANopen,Modbus-CANopen,complex, high-power machines,variable speed drive
- Brochure URL - 343f3cf8a7c08e74123cc519e3ac6d60ed1fda99.pdf(Brochure URL)
- Catalog URL - Schneider_Electric_ATV71HU55N4Z_Catalog.pdf(Catalog URL)
- Computer~Aided [CAD|BIM] Model URL - f2324d6f1bbb48dd46c91dc3ae5d45a61a56f62c.pdf(Computer~Aided [CAD|BIM] Model URL)
- Install Instructions 1 URL - Schneider_Electric_ATV71HU55N4Z_Instruction_Sheet.pdf(Install Instructions 1 URL)
- Install Instructions URL - Schneider_Electric_ATV71HU55N4Z_Instruction_Sheet.pdf(Install Instructions URL)
- Seller Home Page URL - us(Seller Home Page URL)
- User Manual URL - 0d9e010da94330a47fc18d0c487fa205500624c5.pdf(User Manual URL)
- Tech Bulletin URL - 7855e2dbfa3f9603a0a01e5c645d9054a3e16ebe.pdf(Tech Bulletin URL)
- Spec Sheet 1 URL - Schneider_Electric_ATV71HU40N4_Datasheet.pdf(Spec Sheet 1 URL)
- Spec Sheet URL - 09374dcd3315bca341b7058d8a08c69c179fa2cd.pdf(Spec Sheet URL)
- Video - https://www.youtube.com/embed/Jpz4Aelbkuk(Video)
- Tech Drawing URL - 51805732a609ff1272d6f2d19c881e26f74b68e5(Tech Drawing URL)
- Video - https://www.youtube.com/embed/Avmxgw6eeh8(Video)
- Applications
- Features
4 KW, 3 PHASE 380...480 V,5 HP, 3 PHASE 380...480 V,ASYNCHRONOUS MOTORS-SYNCHRONOUS MOTORS,COMPLEX, HIGH-POWER MACHINES |
ADJUSTABLE PI REGULATOR,AGAINST EXCEEDING LIMIT SPEED DRIVE-SHORT-CIRCUIT BETWEEN MOTOR PHASES DRIVE-THERMAL PROTECTION DRIVE-MOTOR PHASE BREAK MOTOR-POWER REMOVAL MOTOR-THERMAL PROTECTION MOTOR-AGAINST INPUT PHASE LOSS DRIVE-BREAK ON THE CONTROL CIRCUIT DRIVE-INPUT PHASE BREAKS DRIVE-LINE SUPPLY OVERVOLTAGE DRIVE-LINE SUPPLY UNDERVOLTAGE DRIVE-OVERCURRENT BETWEEN OUTPUT PHASES AND EARTH DRIVE-OVERHEATING PROTECTION DRIVE-OVERVOLTAGES ON THE DC BUS DRIVE,FLUX VECTOR CONTROL (FVC) WITH SENSOR (CURRENT VECTOR)-ENA (ENERGY ADAPTATION) SYSTEM FOR UNBALANCED LOADS-SENSORLESS FLUX VECTOR CONTROL (SFVC) (VOLTAGE OR CURRENT VECTOR)-VOLTAGE/FREQUENCY RATIO (2 OR 5 POINTS),INTERNAL SUPPLY FOR REFERENCE POTENTIOMETER (1 TO 10 KOHM) 10.5 V DC +/- 5 , <10 MA OVERLOAD AND SHORT-CIRCUIT PROTECTION-INTERNAL SUPPLY 24 V DC 21-27 V), <200 MA OVERLOAD AND SHORT-CIRCUIT PROTECTION,TERMINAL 2.5 MMA², AWG 14 AI1-/AI1+, AI2, AO1, R1A, R1B, R1C, R2A, R2B, LI1...LI6, PWR)-TERMINAL 4 MMA², AWG 10 L1/R, L2/S, L3/T, U/T1, V/T2, W/T3, PC/-, PO, PA/+, PA, PB) |
4 kW motor power |
3-phase |
50/60 Hz supply frequency |
9.3 kVA apparent power |
10.5/7.6 A nominal output current |
0.1/599 Hz output frequency |
4 kHz nominal switching frequency |
1/16 kHz adjustable switching frequency |
4/16 kHz with derating factor switching frequency |
47.5 to 63 Hz network frequency |
54.5 dB noise level |
1/100 in open-loop mode, without speed feedback speed range |
1/50 in open-loop mode, without speed feedback speed range |