Schneider Electric Altistart 22 ATS48C21Y Soft Starter With Heat Sink, IP00 Enclosure
Open Soft Starters
260010
MFG #: ATS48C21Y
Schneider Electric
3276.00000
/ ea
Schneider Electric ATS48C21Y SOFT START 208-690VAC 210A ATS48,-10...40 deg.C without derating-> 40...60 deg.C with current derating of 2 per deg.C-> 40...60 deg.C with current derating of 2 per deg.C,1 to 60 seconds (adjustable),210A,24V,60HP208V - 75HP230V - 150HP460V - 200HP575V,Altistart 48,IEC/EN 60947-4-2, EMC classes A and B, CE,UL ,CSA,DNV,C-Tick,GOST, CCC,NOM,SERPRO AND TCF,IP00,external bypass (optional),soft starter,severe and standard applications-pumping and ventilation machine
- Brochure URL - 11003_9PT1LU7VOI5CXNW3.pdf(Brochure URL)
- Catalog URL - Schneider_Electric_ATS48C21Y_Catalog.pdf(Catalog URL)
- Computer~Aided [CAD|BIM] Model URL(Computer~Aided [CAD|BIM] Model URL)
- Full Eng Drawing URL - Schneider_Electric_ATS48C25Y_Technical_Drawing_1.pdf(Full Eng Drawing URL)
- Install Instructions 1 URL - 11003_AZGHUWCIF6KRM1DE.pdf(Install Instructions 1 URL)
- Install Instructions URL - Schneider_Electric_ATS48C21Y_Installation.pdf(Install Instructions URL)
- Seller Home Page URL - us(Seller Home Page URL)
- Service Manual URL - 11003_NWIYKU6Z7AMGLPDB.pdf(Service Manual URL)
- Service Manual URL - 11003_X4Q3V9KTYRJBCD2O.pdf(Service Manual URL)
- Spec Sheet URL - 11003_Y72GBNDQ1JFWKTIH.pdf(Spec Sheet URL)
- Tech Bulletin URL - 11003_DYVEI4MTAJH5QXWC.pdf(Tech Bulletin URL)
- Tech Bulletin URL - 11003_KOT4A9QJ3PS2Z5UF.pdf(Tech Bulletin URL)
- Tech Drawing URL - 11003_GZEKODMQHR109XUN.pdf(Tech Drawing URL)
- Tech Drawing URL - 11003_Z4PCQS2GLBJE6D7T.pdf(Tech Drawing URL)
- User Manual URL - 11003_EQXNLKU42YWO38B7.pdf(User Manual URL)
- User Manual URL - 11003_WYULO5ATQ4EDHVPF.pdf(User Manual URL)
- Video - https://www.youtube.com/embed/th7HTrRtRc0(Video)
- Applications
- Features
ASYNCHRONOUS MOTORS |
EXTERNAL BYPASS (OPTIONAL) |
-25 to 70 deg C storage temperature |
125 hp at 460 VAC/150 hp at 460 VAC/150 hp at 575 VAC/200 hp at 575 VAC/50 hp at 208 VAC/60 hp at 208 VAC/60 hp at 230 VAC/75 hp at 230 VAC hp Motor power |
180 A Setting current |
With heat sink |
177 to 759 VAC supply voltage limits |
47.5 to 63 Hz network frequency |
Start with torque control type of start |
110 kW at 440 VAC/110 kW at 500 VAC/110 kW at 525 VAC/132 kW at 500 VAC/132 kW at 525 VAC/132 kW at 660 VAC/160 kW at 660 VAC/160 kW at 690 VAC/200 kW at 690 VAC/45 kW at 230 VAC/55 kW at 230 VAC/90 kW at 400 VAC/90 kW at 440 VAC kW Motor power |
125/150/200/50/60/75 hp power rating |