or to view stock quantity and your pricing.
Steiner serves territories in Northern Illinois, Northwest Indiana and Southern Wisconsin. Please for assistance if outside our sales territory.
ILSCO®
ILSCO® SLS-175 SLS Compact Mechanical Terminal Lug, 4 to 3/0 AWG Copper Conductor, 3/8 in Stud, 1 Bolt Holes, Copper
Custom_Product_Images_Illustration
ILSCO®
ILSCO® SLS-175 SLS Compact Mechanical Terminal Lug, 4 to 3/0 AWG Copper Conductor, 3/8 in Stud, 1 Bolt Holes, Copper
SKU945940
MFGR #SLS-175
Your Cost: $18.82/ea
ILSCO® Mechanical Terminal Lug, Compact, Series: SLS, Copper Conductor, 4 to 3/0 AWG Conductor, 3/8 in Stud, 1 Bolt Hole, 1.25 in L x 0.75 in W x 0.156 in THK Tongue, Straight Tongue, 2000 VAC, 3/16 in Hex, Socket Screw, 90 deg C, Copper, 2-3/16 in L x 3/4 in W
ILSCO® Mechanical Terminal Lug, Compact, Series: SLS, Copper Conductor, 4 to 3/0 AWG Conductor, 3/8 in Stud, 1 Bolt Hole, 1.25 in L x 0.75 in W x 0.156 in THK Tongue, Straight Tongue, 2000 VAC, 3/16 in Hex, Socket Screw, 90 deg C, Copper, 2-3/16 in L x 3/4 in W
ARRA Compliant C Buy American Compliant C Catalog Number SLS-175 Country of Origin MX Currency USD Dimensions 2-3/16 in L x 3/4 in W EU RoHS Indicator C Finish Electrolytic Gross Weight Per Pack 0.1620 lb Gross Weight per Pack Metric 0.07 Gross Weight UOM Metric kg Harmonization Tariff Schedule Code 8536904000 Series SLS Specifications 3/16 in Hex Socket Screw, V-Bottom Collar Standards ARRA CompliantBuy American Act/RoHS CompliantCSA File No. LR-29601UL 486A/B/453GE6207PROP65: This product is in compliance with Prop65; it is not known to contain any chemicals associated with this regulation Temperature Rating 90 °C Tongue Size 1.25 in L x 0.75 in W x 0.156 in THK Tongue Type Offset/Straight Type 1-Conductor Compact UNSPSC 39121408 UPC 11 78366982348 UPC 12 78366982348 Voltage Rating 2000 VAC Stock Status NONSTOCK Brand ILSCO® Manufacturer ILSCO Conductor Size 4 to 3/0 AWG Conductor Type Copper Material Copper Number of Bolt Holes 1 Stud Size 3/8 in Range taking to reduce inventory;Re-usable for efficient use and flexibility in the field;Suitable for use in circuits rated 35KV or less;Conductors are wedged between arched pressure bar and collar establishing positive contact and firm permanent grip with the v-bottom collar;DB Suffix indicates UL 467 listed for direct burial Re-usable Suitable for use in circuits rated 35kV or less, Proper high voltage spacing and insulation techniques must be used Range taking for reduced inventories and flexibility Manufactured from electrolytic copper tubing and strip stock Provides maximum conductivity and strength Ensures reliability for copper conductor Compact design saves space and reduces installation time Wires are wedged between arched pressure bar and collar establishing positive contact and firm permanent grip V-bottom collar 1 stud of 3/8 in 25/Pack, Standard Package
content loaded
content loaded
content loaded
content loaded
- Attributes
- Documents & Resources
- Features
- Substitute Products
| ARRA Compliant | C |
| Buy American Compliant | C |
| Catalog Number | SLS-175 |
| Country of Origin | MX |
| Currency | USD |
| Dimensions | 2-3/16 in L x 3/4 in W |
| EU RoHS Indicator | C |
| Finish | Electrolytic |
| Gross Weight Per Pack | 0.1620 lb |
| Gross Weight per Pack Metric | 0.07 |
| Gross Weight UOM Metric | kg |
| Harmonization Tariff Schedule Code | 8536904000 |
| Series | SLS |
| Specifications | 3/16 in Hex Socket Screw, V-Bottom Collar |
| Standards | ARRA CompliantBuy American Act/RoHS CompliantCSA File No. LR-29601UL 486A/B/453GE6207PROP65: This product is in compliance with Prop65; it is not known to contain any chemicals associated with this regulation |
| Temperature Rating | 90 °C |
| Tongue Size | 1.25 in L x 0.75 in W x 0.156 in THK |
| Tongue Type | Offset/Straight |
| Type | 1-Conductor Compact |
| UNSPSC | 39121408 |
| UPC 11 | 78366982348 |
| UPC 12 | 78366982348 |
| Voltage Rating | 2000 VAC |
| Stock Status | NONSTOCK |
| Brand | ILSCO® |
| Manufacturer | ILSCO |
| Conductor Size | 4 to 3/0 AWG |
| Conductor Type | Copper |
| Material | Copper |
| Number of Bolt Holes | 1 |
| Stud Size | 3/8 in |
| Range taking to reduce inventory;Re-usable for efficient use and flexibility in the field;Suitable for use in circuits rated 35KV or less;Conductors are wedged between arched pressure bar and collar establishing positive contact and firm permanent grip with the v-bottom collar;DB Suffix indicates UL 467 listed for direct burial |
| Re-usable |
| Suitable for use in circuits rated 35kV or less, Proper high voltage spacing and insulation techniques must be used |
| Range taking for reduced inventories and flexibility |
| Manufactured from electrolytic copper tubing and strip stock |
| Provides maximum conductivity and strength |
| Ensures reliability for copper conductor |
| Compact design saves space and reduces installation time |
| Wires are wedged between arched pressure bar and collar establishing positive contact and firm permanent grip |
| V-bottom collar |
| 1 stud of 3/8 in |
| 25/Pack, Standard Package |