or to view stock quantity and your pricing.
Steiner serves territories in Northern Illinois, Northwest Indiana and Southern Wisconsin. Please for assistance if outside our sales territory.
Fluke®
Fluke® FLUKE-175-ESFP Digital Multimeter, 1000 VDC/VAC, 10 A, 50 MOhm, 1000 VAC/VDC, 10 A, 50 M Ohm, Digital Display
Custom_Product_Images_Illustration
Fluke®
Fluke® FLUKE-175-ESFP Digital Multimeter, 1000 VDC/VAC, 10 A, 50 MOhm, 1000 VAC/VDC, 10 A, 50 M Ohm, Digital Display
SKU147307
MFGR #FLUKE-175-ESFP
$/ea
Fluke 170 Series True RMS digital multimeters is preferred solution for the precisie, reliable and easy of use . This is the industry standard, with all the features you need to troubleshoot and repair so many problems in electrical and electronic systems. Fluke 170 Series digital multimeters give you True RMS voltage and current measurements, 6000-count resolution, manual and automatic ranging and provide frequency, capacitance, resistance, continuity and diode measurements. In addition, the Fluke 177 and 179 provide higher 0.09 basic accuracy, a digital display with analog bar graph and backlight. And the Fluke 179 delivers temperature measurements.
Fluke 170 Series True RMS digital multimeters is preferred solution for the precisie, reliable and easy of use . This is the industry standard, with all the features you need to troubleshoot and repair so many problems in electrical and electronic systems. Fluke 170 Series digital multimeters give you True RMS voltage and current measurements, 6000-count resolution, manual and automatic ranging and provide frequency, capacitance, resistance, continuity and diode measurements. In addition, the Fluke 177 and 179 provide higher 0.09 basic accuracy, a digital display with analog bar graph and backlight. And the Fluke 179 delivers temperature measurements.
Amperage Rating 10 A Bandwidth 2.0 % + 3 (500 Hz to 1 kHz) Battery Type 9 VDC Alkaline NEDA 1604/1604A Capacitance 10000 uF Catalog Number FLUKE-175-ESFP Country of Origin UKN Dimensions 7.28 in H x 3.54 in W x 1.7 in D Diode Test Yes in Display Digital Frequency Rating 100 kHz Gross Weight Per Pack 1.5900 lb Interface Yes Material Plastic Measuring Range 1000 VDC/VAC, 10 A, 50 MOhm Peak Hold No Resistance 50 MOhm Resolution Digital: 6000 counts, updates 4/sec; Bar Graph: 33 segments, Updates 40/sec; Frequency: 10,000 counts; Capacitance: 1,000 counts Series Digital Multimeter Temperature Rating -10 to 50 °C Type Fluke UNSPSC 41113630 UPC 11 09596909518 UPC 12 09596909518 Voltage Rating 1000 VAC//VDC Stock Status NONSTOCK Brand Fluke® Manufacturer Fluke Corporation Manual and automatic ranging Display hold and auto hold Frequency and capacitance measurements Min-max-average recording Closed case calibration through front panel Ergonomic case with integrated protective holster Digital 6000 count, update 4/sec, bar graph 33 segments, update 40/sec Resistance range - 600 Ohm with accuracy of (0.9% + 2), 6 kOhm, 60 kOhm, 600 kOhm, 6 MOhm with accuracy of (0.9% + 1), 50 MOhm with accuracy of (1.5% + 3) Capacitance range 1000 nF, 10 uF, 100 uF with accuracy of (1.2% + 2), 9999 uF with accuracy of 10% typical Frequency range 99.99, 999.9, 9.999, 99.99 kHz with accuracy of (0.1% + 1) 200 hr typical alkaline Resistance range- 600 Ohm with accuracy of (0.9 % + 2), 6 kOhm, 60 kOhm, 600 kOhm, 6 MOhm with accuracy of (0.9 % + 1), 50 MOhm with accuracy of (1.5% + 3) Capacitance range 1000 nF, 10 uF, 100 uF with accuracy of (1.2 % + 2), 9999 uF with accuracy of 10% typical Frequency range 99.99, 999.9, 9.999, 99.99 kHz with accuracy of (0.1% + 1) 200 hrs typical Alkaline
content loaded
content loaded
content loaded
content loaded
- Attributes
- Documents & Resources
- Features
- Substitute Products
| Amperage Rating | 10 A |
| Bandwidth | 2.0 % + 3 (500 Hz to 1 kHz) |
| Battery Type | 9 VDC Alkaline NEDA 1604/1604A |
| Capacitance | 10000 uF |
| Catalog Number | FLUKE-175-ESFP |
| Country of Origin | UKN |
| Dimensions | 7.28 in H x 3.54 in W x 1.7 in D |
| Diode Test | Yes in |
| Display | Digital |
| Frequency Rating | 100 kHz |
| Gross Weight Per Pack | 1.5900 lb |
| Interface | Yes |
| Material | Plastic |
| Measuring Range | 1000 VDC/VAC, 10 A, 50 MOhm |
| Peak Hold | No |
| Resistance | 50 MOhm |
| Resolution | Digital: 6000 counts, updates 4/sec; Bar Graph: 33 segments, Updates 40/sec; Frequency: 10,000 counts; Capacitance: 1,000 counts |
| Series | Digital Multimeter |
| Temperature Rating | -10 to 50 °C |
| Type | Fluke |
| UNSPSC | 41113630 |
| UPC 11 | 09596909518 |
| UPC 12 | 09596909518 |
| Voltage Rating | 1000 VAC//VDC |
| Stock Status | NONSTOCK |
| Brand | Fluke® |
| Manufacturer | Fluke Corporation |
| Manual and automatic ranging |
| Display hold and auto hold |
| Frequency and capacitance measurements |
| Min-max-average recording |
| Closed case calibration through front panel |
| Ergonomic case with integrated protective holster |
| Digital 6000 count, update 4/sec, bar graph 33 segments, update 40/sec |
| Resistance range - 600 Ohm with accuracy of (0.9% + 2), 6 kOhm, 60 kOhm, 600 kOhm, 6 MOhm with accuracy of (0.9% + 1), 50 MOhm with accuracy of (1.5% + 3) |
| Capacitance range 1000 nF, 10 uF, 100 uF with accuracy of (1.2% + 2), 9999 uF with accuracy of 10% typical |
| Frequency range 99.99, 999.9, 9.999, 99.99 kHz with accuracy of (0.1% + 1) |
| 200 hr typical alkaline |
| Resistance range- 600 Ohm with accuracy of (0.9 % + 2), 6 kOhm, 60 kOhm, 600 kOhm, 6 MOhm with accuracy of (0.9 % + 1), 50 MOhm with accuracy of (1.5% + 3) |
| Capacitance range 1000 nF, 10 uF, 100 uF with accuracy of (1.2 % + 2), 9999 uF with accuracy of 10% typical |
| Frequency range 99.99, 999.9, 9.999, 99.99 kHz with accuracy of (0.1% + 1) |
| 200 hrs typical Alkaline |