or to view stock quantity and your pricing.
Steiner serves territories in Northern Illinois, Northwest Indiana and Southern Wisconsin. Please for assistance if outside our sales territory.
Ferraz Shawmut
Ferraz Shawmut MPDB69313 MPDB Power Distribution Block, 600 VAC, 760 A, 3 Poles, 4 AWG to 500 kcmil Wire, Polycarbonate
Custom_Product_Images_Illustration
Ferraz Shawmut
Ferraz Shawmut MPDB69313 MPDB Power Distribution Block, 600 VAC, 760 A, 3 Poles, 4 AWG to 500 kcmil Wire, Polycarbonate
SKU819405
MFGR #MPDB69313
Your Cost: $391.33/ea
Mersen power distribution blocks provide a safe and easy method of splicing cables, splitting primary power into secondary circuits and fulfilling requirements for fixed junction tap-off points. All blocks are UL and CSA approved while meeting spacing requirements for feeder and branch circuits in conjunction with UL508A and the National Electrical Code. PDB options include single or dual conductor primary inputs and up to 30 secondary outputs. Specialty blocks are available allowing for up to 7 primary inputs. The MPDB series is offered in three size categories: miniature (MPDB62 and MPDB63 series), intermediate (MPDB66 and MPDB67 series), and large (MPDB68 and MPDB69 series), in both aluminum and copper.
Mersen power distribution blocks provide a safe and easy method of splicing cables, splitting primary power into secondary circuits and fulfilling requirements for fixed junction tap-off points. All blocks are UL and CSA approved while meeting spacing requirements for feeder and branch circuits in conjunction with UL508A and the National Electrical Code. PDB options include single or dual conductor primary inputs and up to 30 secondary outputs. Specialty blocks are available allowing for up to 7 primary inputs. The MPDB series is offered in three size categories: miniature (MPDB62 and MPDB63 series), intermediate (MPDB66 and MPDB67 series), and large (MPDB68 and MPDB69 series), in both aluminum and copper.
Alternate Catalog Number MPDB69313 Application Cable splicing Splitting primary power into secondary circuits Fixed junction tap-off points ARRA Compliant X Buy American Compliant X Catalog Number MPDB69313 Color Black Conductor Range 500-#4 , 4/0-#6 Connection Box To Box Country of Origin MX Currency USD Dimensions 4.75 in H x 7.89 in W x 5.7 in D EU RoHS Indicator Y Finish Tin Plated Gross Volume Per Pack 159.65 Gross Weight Per Pack 5.4000 lb Gross Weight per Pack Metric 2.45 Gross Weight UOM Metric kg Harmonization Tariff Schedule Code 8536904000 Height 3.55 in Height [Metric] 90.1700 mm Length 5.70 in Length [Metric] 144.7800 mm Mounting Direct Screw Mount Number Of Conductors 2 , 4 Number Of Poles 3 Primary Connections|Pole 2 Secondary Connection|Pole 4 Series MPDB Short Circuit Current Rating 100 kA Size 5.7 x 7.89 x 3.55 in Standard UL Listed - File E352417 CSA Certified - Class 6228 01 RoHS Compliant Standards RoHS CompliantUL 1953 File No. E352417CSA Class 6228-01 Type Open-Style Power Distribution Blocks UNSPSC 39121410 UPC 11 78200145264 UPC 12 78200145264 Width 7.89 in Width [Metric] 200.4060 mm Stock Status NONSTOCK Brand Ferraz Shawmut Manufacturer Ferraz Shawmut Amperage Rating 760 A Material Polycarbonate Voltage Rating 600 VAC Wire Size 4 AWG to 500 kcmil, 6 to 4/0 AWG Cable splicing Splitting primary power into secondary circuits Fixed junction tap-off points • Adder Poles: All sizes have optional adder poles for increased flexibility and ease-of-use. Adder poles can be stacked to form multi-pole units in the field witho ut the use of tools. Adder poles allow for customization of primary and secondary wire combinations. End barriers are also available for sale, catalog numbers can be found in the catalog number selection tables for each size block • Wire Connectors: Standard aluminum and copper wire connectors are available. Aluminum connectors accept both AL or CU wire while copper connectors accept CU wire only. Connectors are all 1-piece tin-plated • Insulators: Insulators are virtually unbreakable, made of glass-filled polycarbonate. “Seethrough,” hinged safety covers are optional and provide a greater degree of safety and shock resistance where required. Hinged covers can be installed without tools • Spacings: 1 inch through air and 2 inches over surface between uninsulated live parts of opposite polarity meets requirements for feeder and branch circuit applications of UL508A • Safety Covers: Polycarbonate safety covers provide dead-front protection. One cover is needed for each pole. Each cover has a test probe hole in the center for circuit checking. Covers are optional accessories and catalog numbers can be found in the catalog selection tables for each size block All sizes have optional adder poles for increased flexibility and ease-of-use Adder poles can be stacked to form multi-pole units in the field without the use of tools, adder poles allow for customization of primary and secondary wire combinations End barriers are also available for sale, catalog numbers can be found in the catalog number selection tables for each size block Aluminum connectors accept both aluminum or copper wire while copper connectors accept copper wire only and all 1-piece tin plated Insulators are virtually unbreakable, made of glass filled polycarbonate, "see-through" hinged safety covers are optional and provide a greater degree of safety and shock resistance where required, hinged covers can be installed without tools 1 in through air and 2 in over surface between uninsulated live parts of opposite polarity meets requirements for feeder and branch circuit applications of UL 508A Polycarbonate safety covers provide dead front protection Each cover has a test probe hole in the center for circuit checking Covers are optional accessories and catalog numbers can be found in the catalog selection tables for each size block Tin plated aluminum contact One cover is needed for each pole
content loaded
content loaded
content loaded
content loaded
content loaded
- Attributes
- Documents & Resources
- Applications
- Features
- Substitute Products
| Alternate Catalog Number | MPDB69313 |
| Application | Cable splicing Splitting primary power into secondary circuits Fixed junction tap-off points |
| ARRA Compliant | X |
| Buy American Compliant | X |
| Catalog Number | MPDB69313 |
| Color | Black |
| Conductor Range | 500-#4 , 4/0-#6 |
| Connection | Box To Box |
| Country of Origin | MX |
| Currency | USD |
| Dimensions | 4.75 in H x 7.89 in W x 5.7 in D |
| EU RoHS Indicator | Y |
| Finish | Tin Plated |
| Gross Volume Per Pack | 159.65 |
| Gross Weight Per Pack | 5.4000 lb |
| Gross Weight per Pack Metric | 2.45 |
| Gross Weight UOM Metric | kg |
| Harmonization Tariff Schedule Code | 8536904000 |
| Height | 3.55 in |
| Height [Metric] | 90.1700 mm |
| Length | 5.70 in |
| Length [Metric] | 144.7800 mm |
| Mounting | Direct Screw Mount |
| Number Of Conductors | 2 , 4 |
| Number Of Poles | 3 |
| Primary Connections|Pole | 2 |
| Secondary Connection|Pole | 4 |
| Series | MPDB |
| Short Circuit Current Rating | 100 kA |
| Size | 5.7 x 7.89 x 3.55 in |
| Standard | UL Listed - File E352417 CSA Certified - Class 6228 01 RoHS Compliant |
| Standards | RoHS CompliantUL 1953 File No. E352417CSA Class 6228-01 |
| Type | Open-Style Power Distribution Blocks |
| UNSPSC | 39121410 |
| UPC 11 | 78200145264 |
| UPC 12 | 78200145264 |
| Width | 7.89 in |
| Width [Metric] | 200.4060 mm |
| Stock Status | NONSTOCK |
| Brand | Ferraz Shawmut |
| Manufacturer | Ferraz Shawmut |
| Amperage Rating | 760 A |
| Material | Polycarbonate |
| Voltage Rating | 600 VAC |
| Wire Size | 4 AWG to 500 kcmil, 6 to 4/0 AWG |
| Cable splicing Splitting primary power into secondary circuits Fixed junction tap-off points |
| • Adder Poles: All sizes have optional adder poles for increased flexibility and ease-of-use. Adder poles can be stacked to form multi-pole units in the field witho ut the use of tools. Adder poles allow for customization of primary and secondary wire combinations. End barriers are also available for sale, catalog numbers can be found in the catalog number selection tables for each size block • Wire Connectors: Standard aluminum and copper wire connectors are available. Aluminum connectors accept both AL or CU wire while copper connectors accept CU wire only. Connectors are all 1-piece tin-plated • Insulators: Insulators are virtually unbreakable, made of glass-filled polycarbonate. “Seethrough,” hinged safety covers are optional and provide a greater degree of safety and shock resistance where required. Hinged covers can be installed without tools • Spacings: 1 inch through air and 2 inches over surface between uninsulated live parts of opposite polarity meets requirements for feeder and branch circuit applications of UL508A • Safety Covers: Polycarbonate safety covers provide dead-front protection. One cover is needed for each pole. Each cover has a test probe hole in the center for circuit checking. Covers are optional accessories and catalog numbers can be found in the catalog selection tables for each size block |
| All sizes have optional adder poles for increased flexibility and ease-of-use |
| Adder poles can be stacked to form multi-pole units in the field without the use of tools, adder poles allow for customization of primary and secondary wire combinations |
| End barriers are also available for sale, catalog numbers can be found in the catalog number selection tables for each size block |
| Aluminum connectors accept both aluminum or copper wire while copper connectors accept copper wire only and all 1-piece tin plated |
| Insulators are virtually unbreakable, made of glass filled polycarbonate, "see-through" hinged safety covers are optional and provide a greater degree of safety and shock resistance where required, hinged covers can be installed without tools |
| 1 in through air and 2 in over surface between uninsulated live parts of opposite polarity meets requirements for feeder and branch circuit applications of UL 508A |
| Polycarbonate safety covers provide dead front protection |
| Each cover has a test probe hole in the center for circuit checking |
| Covers are optional accessories and catalog numbers can be found in the catalog selection tables for each size block |
| Tin plated aluminum contact |
| One cover is needed for each pole |