Burndy® GC2929CT GC-CT Cable Tray Ground Clamp, Aluminum/Copper Conductor, 2/0 AWG to 250 kcmil Conductor, Copper, TiN Coated
Custom_Product_Images_Illustration
Burndy® GC2929CT GC-CT Cable Tray Ground Clamp, Aluminum/Copper Conductor, 2/0 AWG to 250 kcmil Conductor, Copper, TiN Coated
SKU282120
MFGR #GC2929CT
Your Cost: $47.27/ea
List: BURNDY® Cable Tray Ground Clamp, Series: GC-CT, Aluminum/Copper Conductor, 2/0 AWG to 250 kcmil Conductor, Copper, TiN Coated, 2.2 in H x 1.98 in W
BURNDY® Cable Tray Ground Clamp, Series: GC-CT, Aluminum/Copper Conductor, 2/0 AWG to 250 kcmil Conductor, Copper, TiN Coated, 2.2 in H x 1.98 in W
Application For Direct Burial Applications In Concrete Or Earth And For Used With Aluminum Or Galvanized Steel Cable Tray ARRA Compliant C Buy American Compliant C Catalog Number GC2929CT Country of Origin MX Dimensions 2.2 in H x 1.98 in W EU RoHS Indicator Y Gross Weight Per Pack 0.3700 lb Gross Weight per Pack Metric 0.17 Gross Weight UOM Metric kg Harmonization Tariff Schedule Code 8535908060 Height 2.20 in Height [Metric] 5.5880 cm Length 1.12 in Length [Metric] 2.8448 cm Returnable Y Series GC-CT Specifications 2/0 AWG to 250 kcmil Aluminum Conductor, 4/0 AWG Solid Copper Conductor, 2/0 AWG to 250 kcmil Stranded Copper Conductor, 3/8-16 Stud, 0.56 in Cross Flats, 240 in-lb Installation Torque Standard UL467 Standards UL 467, CSA Certified, RoHS Compliant Sub Brand Mechanical Connector Type GC-CT UNSPSC 39121408 UPC 11 78181022058 UPC 12 781810220580 Width 1.98 in Width [Metric] 5.0292 cm Stock Status NORMALLY STOCKED Brand BURNDY® Manufacturer BURNDY® Conductor Size 2/0 AWG to 250 kcmil Conductor Type Solid/Stranded Aluminum/Copper Finish Tin Plated Material Copper Alloy For Direct Burial Applications In Concrete Or Earth And For Used With Aluminum Or Galvanized Steel Cable Tray Features: Made Of Tin-Plated Cast Copper Alloy, It Accommodates Either One Or Two Conductors, Copper Or Aluminum Cable, In Addition To A Low Profile Head With A Deep Phillips Recess, The Galvanized Steel Bolt Has A Ribbed Neck Which Prevents Rotation During Installation When Installed In A 0.44 Diameter Hole, When Used On Aluminum Conductor, The Cable Must Be Scratch Brushed And PENETROX A Joint Compound Must Be Used On Cable And Connector, UL467 Listed For Copper Conductor Only, Suitable For Direct Burial In Concrete Or Earth, The Bolt Head Is Mounted On The Inside Wall Of Cable Tray To Avoid Damage To The Cable Insulation, May Be Used With Aluminum Or Galvanized Steel Cable Tray, Stud/bolt Size: 3/8-16, Installation Torque: 240 IN-LB, Width: 1.98 IN, Cross Flats: 0.56 IN, Height: 2.2 IN, Dimension B: 1.12 IN It accommodates either one or two conductors, copper or aluminum cable In addition to a low profile head with a deep Phillips recess The galvanized steel bolt has a ribbed neck which prevents rotation during installation when installed in a 0.44 India hole When used on aluminum conductor, the cable must be scratch brushed and PENETROX a joint compound must be used on cable and connector Suitable for direct burial in concrete or earth The bolt head is mounted on the inside wall of cable tray to avoid damage to the cable insulation May be used with aluminum or galvanized steel cable tray 2/0 AWG - 250 kcmil aluminum conductor 4/0 AWG solid copper conductor 2/0 AWG - 250 kcmil stranded copper conductor 3/8-16 stud 0.56 cross flats 240 in-lb installation torque
content loaded
content loaded
content loaded
content loaded
content loaded
- Attributes
- Documents & Resources
- Applications
- Features
- Substitute Products
Application | For Direct Burial Applications In Concrete Or Earth And For Used With Aluminum Or Galvanized Steel Cable Tray |
ARRA Compliant | C |
Buy American Compliant | C |
Catalog Number | GC2929CT |
Country of Origin | MX |
Dimensions | 2.2 in H x 1.98 in W |
EU RoHS Indicator | Y |
Gross Weight Per Pack | 0.3700 lb |
Gross Weight per Pack Metric | 0.17 |
Gross Weight UOM Metric | kg |
Harmonization Tariff Schedule Code | 8535908060 |
Height | 2.20 in |
Height [Metric] | 5.5880 cm |
Length | 1.12 in |
Length [Metric] | 2.8448 cm |
Returnable | Y |
Series | GC-CT |
Specifications | 2/0 AWG to 250 kcmil Aluminum Conductor, 4/0 AWG Solid Copper Conductor, 2/0 AWG to 250 kcmil Stranded Copper Conductor, 3/8-16 Stud, 0.56 in Cross Flats, 240 in-lb Installation Torque |
Standard | UL467 |
Standards | UL 467, CSA Certified, RoHS Compliant |
Sub Brand | Mechanical Connector |
Type | GC-CT |
UNSPSC | 39121408 |
UPC 11 | 78181022058 |
UPC 12 | 781810220580 |
Width | 1.98 in |
Width [Metric] | 5.0292 cm |
Stock Status | NORMALLY STOCKED |
Brand | BURNDY® |
Manufacturer | BURNDY® |
Conductor Size | 2/0 AWG to 250 kcmil |
Conductor Type | Solid/Stranded Aluminum/Copper |
Finish | Tin Plated |
Material | Copper Alloy |
For Direct Burial Applications In Concrete Or Earth And For Used With Aluminum Or Galvanized Steel Cable Tray |
Features: Made Of Tin-Plated Cast Copper Alloy, It Accommodates Either One Or Two Conductors, Copper Or Aluminum Cable, In Addition To A Low Profile Head With A Deep Phillips Recess, The Galvanized Steel Bolt Has A Ribbed Neck Which Prevents Rotation During Installation When Installed In A 0.44 Diameter Hole, When Used On Aluminum Conductor, The Cable Must Be Scratch Brushed And PENETROX A Joint Compound Must Be Used On Cable And Connector, UL467 Listed For Copper Conductor Only, Suitable For Direct Burial In Concrete Or Earth, The Bolt Head Is Mounted On The Inside Wall Of Cable Tray To Avoid Damage To The Cable Insulation, May Be Used With Aluminum Or Galvanized Steel Cable Tray, Stud/bolt Size: 3/8-16, Installation Torque: 240 IN-LB, Width: 1.98 IN, Cross Flats: 0.56 IN, Height: 2.2 IN, Dimension B: 1.12 IN |
It accommodates either one or two conductors, copper or aluminum cable |
In addition to a low profile head with a deep Phillips recess |
The galvanized steel bolt has a ribbed neck which prevents rotation during installation when installed in a 0.44 India hole |
When used on aluminum conductor, the cable must be scratch brushed and PENETROX a joint compound must be used on cable and connector |
Suitable for direct burial in concrete or earth |
The bolt head is mounted on the inside wall of cable tray to avoid damage to the cable insulation |
May be used with aluminum or galvanized steel cable tray |
2/0 AWG - 250 kcmil aluminum conductor |
4/0 AWG solid copper conductor |
2/0 AWG - 250 kcmil stranded copper conductor |
3/8-16 stud |
0.56 cross flats |
240 in-lb installation torque |