or to view stock quantity and your pricing.
Steiner serves territories in Northern Illinois, Northwest Indiana and Southern Wisconsin. Please for assistance if outside our sales territory.
BANNER®
Banner Engineering SME312FQD SM3 Fiber Optic Sensor, Rectangle Shape, Infrared Sensing Beam, 0.5 ms Response Time
BANNER®
Banner Engineering SME312FQD SM3 Fiber Optic Sensor, Rectangle Shape, Infrared Sensing Beam, 0.5 ms Response Time
SKU106495
MFGR #SME312FQD
Your Cost: $161.63/ea
List: Banner Engineering Fiber Optic Sensor, Series: SM3, Rectangle, Glass Fiber Optic Sensing Method, Infrared Sensing Beam, 0.5 ms Response, Single Discrete NPN/PNP Output, 10 to 30 VDC, 4-Pin M12 Quick Disconnect, LED Light Source, NEMA 1/2/3/3S/4/4X/6/12/IP67/IP13, -20 to 70 deg C Operating, Environmental Conditions: 90% at 50 deg C Maximum Relative Humidity
Banner Engineering Fiber Optic Sensor, Series: SM3, Rectangle, Glass Fiber Optic Sensing Method, Infrared Sensing Beam, 0.5 ms Response, Single Discrete NPN/PNP Output, 10 to 30 VDC, 4-Pin M12 Quick Disconnect, LED Light Source, NEMA 1/2/3/3S/4/4X/6/12/IP67/IP13, -20 to 70 deg C Operating, Environmental Conditions: 90% at 50 deg C Maximum Relative Humidity
Catalog Number SME312FQD Connection Type 4-Pin M12 Quick Disconnect Country of Origin US Enclosure Type NEMA 1/2/3/3S/4/4X/6/12/IP67/IP13 Environmental Conditions 90% at 50 deg C Maximum Relative Humidity Gross Weight Per Pack 0.2200 lb Light Source LED Operating Temperature -20 to 70 °C Sensing Method Glass Fiber Optic Series SM3 Standards CE Marked, UL Listed UNSPSC 39121528 UPC 11 66248853714 UPC 12 66248853714 Voltage Rating 10 to 30 VDC Stock Status NONSTOCK Brand BANNER® Manufacturer Banner Engineering Corp. Output Type Single Discrete NPN/PNP Response Time 0.5 ms Sensing Beam Infrared Shape Rectangular Microprocessor-based TEACH-mode sensors, include AID™ function; Easy push-button programming automatically adjusts sensitivity to optimal setting; Easy output programming eliminates the need for Light or Dark Operate selection; Separate TEACH input allows remote programming by an external device, such as a switch or a process controller; The first condition presented during TEACH mode becomes the output ON condition; Sensing range varies by sensing mode and fiber optics used; Fibers withstand high temperatures, extreme moisture, corrosive materials, vibration and shock and are immune to electrical noise; Glass fibers are not recommended for applications requiring bending or repeated flexing (see plastic fiber models); Protected against reverse polarity, transient voltages and against false pulse on power-up and continuous overload or short-circuit of outp Thermoplastic primary housing material 100 us repeatability Gain (sensitivity) adjustment screw Alignment indicator device Light/dark operate select switch Clockwise light operate (outputs conduct when sensing light is received) Counter clockwise dark operate (outputs conduct when sensing light is not received) 4-pin M12/euro style quick disconnect cable connection Teach button adjustment 1000 ms delay at power-up 4-pin M12 integral quick disconnect cable connection
content loaded
content loaded
content loaded
content loaded
- Attributes
- Documents & Resources
- Features
- Substitute Products
Catalog Number | SME312FQD |
Connection Type | 4-Pin M12 Quick Disconnect |
Country of Origin | US |
Enclosure Type | NEMA 1/2/3/3S/4/4X/6/12/IP67/IP13 |
Environmental Conditions | 90% at 50 deg C Maximum Relative Humidity |
Gross Weight Per Pack | 0.2200 lb |
Light Source | LED |
Operating Temperature | -20 to 70 °C |
Sensing Method | Glass Fiber Optic |
Series | SM3 |
Standards | CE Marked, UL Listed |
UNSPSC | 39121528 |
UPC 11 | 66248853714 |
UPC 12 | 66248853714 |
Voltage Rating | 10 to 30 VDC |
Stock Status | NONSTOCK |
Brand | BANNER® |
Manufacturer | Banner Engineering Corp. |
Output Type | Single Discrete NPN/PNP |
Response Time | 0.5 ms |
Sensing Beam | Infrared |
Shape | Rectangular |
Microprocessor-based TEACH-mode sensors, include AID™ function; Easy push-button programming automatically adjusts sensitivity to optimal setting; Easy output programming eliminates the need for Light or Dark Operate selection; Separate TEACH input allows remote programming by an external device, such as a switch or a process controller; The first condition presented during TEACH mode becomes the output ON condition; Sensing range varies by sensing mode and fiber optics used; Fibers withstand high temperatures, extreme moisture, corrosive materials, vibration and shock and are immune to electrical noise; Glass fibers are not recommended for applications requiring bending or repeated flexing (see plastic fiber models); Protected against reverse polarity, transient voltages and against false pulse on power-up and continuous overload or short-circuit of outp |
Thermoplastic primary housing material |
100 us repeatability |
Gain (sensitivity) adjustment screw |
Alignment indicator device |
Light/dark operate select switch |
Clockwise light operate (outputs conduct when sensing light is received) |
Counter clockwise dark operate (outputs conduct when sensing light is not received) |
4-pin M12/euro style quick disconnect cable connection |
Teach button adjustment |
1000 ms delay at power-up |