or to view stock quantity and your pricing.
Steiner serves territories in Northern Illinois, Northwest Indiana and Southern Wisconsin. Please for assistance if outside our sales territory.
Banner Engineering SM2A312D Mani-Beam® 312 Photoelectric Sensor, Rectangular Shape, 380 mm Sensing, Infrared Sensing Beam
Custom_Product_Images_Illustration
Banner Engineering SM2A312D Mani-Beam® 312 Photoelectric Sensor, Rectangular Shape, 380 mm Sensing, Infrared Sensing Beam
SKU13456
MFGR #SM2A312D
Your Cost: $206.00/ea
Banner Engineering Mani-Beam® Photoelectric Sensor, Series: 312, Rectangular, Diffuse Sensing Method, 380 mm Sensing Range, Infrared Sensing Beam, 8 ms Response, Switch Output, 24/240 VAC, 50/60 Hz, Cable, LED Light Source, 65.8 mm L x 12 mm W x 33.3 mm H, NEMA 1/2/3/3S/4/4X/12/13/IP67, -20 to 70 deg C Operating, Environmental Conditions: 90% at 50 deg C
Banner Engineering Mani-Beam® Photoelectric Sensor, Series: 312, Rectangular, Diffuse Sensing Method, 380 mm Sensing Range, Infrared Sensing Beam, 8 ms Response, Switch Output, 24/240 VAC, 50/60 Hz, Cable, LED Light Source, 65.8 mm L x 12 mm W x 33.3 mm H, NEMA 1/2/3/3S/4/4X/12/13/IP67, -20 to 70 deg C Operating, Environmental Conditions: 90% at 50 deg C
Catalog Number SM2A312D Connection Type Cable Country of Origin US Enclosure Type NEMA 1/2/3/3S/4/4X/12/13/IP67 Environmental Conditions 90% at 50 deg C Frequency Rating 50/60 Hz Gross Weight Per Pack 0.3360 lb Light Source LED Operating Temperature -20 to 70 °C Sensing Method Diffuse Series 312 Size 65.8 mm L x 12 mm W x 33.3 mm H Standards CE Marked, cCSAus Certified, cULus Listed , RoHS Complaint UNSPSC 39121528 UPC 11 66248825965 UPC 12 66248825965 Voltage Rating 24/240 VAC Stock Status NORMALLY STOCKED Brand Banner® Manufacturer Banner Engineering Corp. Output Type Switch Response Time 8 ms Sensing Beam Infrared Sensing Range 380 mm Shape Rectangular Rectangular with M18 barrel housing style; Protected against transient voltages, false pulse on power-up; Controls are located on the rear panel of the sensor and are protected by a gasketed, clear acrylic cover; Totally encapsulated, O-ring sealing, stainless steel screws construction; Overload conditions can destroy ac MINI-BEAM sensors. Directly wiring sensor without load series, across hot and neutral will damage sensor (except emitter models); Low-voltage use requires careful analysis of the load to determine if the sensor's leakage current or on-state voltage will interfere with proper operation of the load; The false-pulse protection feature may cause momentary drop-out of the load when the sensor is wired in series or parallel with mechanical switch contacts; Controls are located on rear panel of sensor and protected by a gasketed, clear acrylic co Protected against transient voltages, false pulse on power-up Controls are located on the rear panel of the sensor and are protected by a gasketed, clear acrylic cover Totally encapsulated, O-ring sealing, stainless steel screws construction Overload conditions can destroy ac MINI-BEAM sensors. Directly wiring sensor without load series, across hot and neutral will damage sensor (except emitter models) Low-voltage use requires careful analysis of the load to determine if the sensors leakage current or on-state voltage will interfere with proper operation of the load The false-pulse protection feature may cause momentary drop-out of the load when the sensor is wired in series or parallel with mechanical switch contacts Controls are located on rear panel of sensor and protected by a gasketed, clear acrylic cove 5 mA minimum load current, 300 mA to 50 deg C, 100 mA to 70 deg C maximum steady-state load capability, 3 A for 1 sec (non-repetitive), 10 A For 1 cycle (non-repetitive) inrush capability Less than or equal to 5 V at 300 mA load and less than or equal to 10 V at 15 mA load on-state voltage drop Self-contained diffuse mode photoelectric sensor Less than 1.7 mA off-state output leakage 8 ms on/off response time 880 nm infrared LED sensing beam Acrylic lens, 90 percent at 50 deg C (non-condensing) relative humidity 2 m cable connection Thermoplastic reinforced VALOX enclosure Light/dark operate, solid-state AC switch output 18 mm barrel diameter Self-Contained
content loaded
content loaded
content loaded
content loaded
- Attributes
- Documents & Resources
- Features
- Substitute Products
| Catalog Number | SM2A312D |
| Connection Type | Cable |
| Country of Origin | US |
| Enclosure Type | NEMA 1/2/3/3S/4/4X/12/13/IP67 |
| Environmental Conditions | 90% at 50 deg C |
| Frequency Rating | 50/60 Hz |
| Gross Weight Per Pack | 0.3360 lb |
| Light Source | LED |
| Operating Temperature | -20 to 70 °C |
| Sensing Method | Diffuse |
| Series | 312 |
| Size | 65.8 mm L x 12 mm W x 33.3 mm H |
| Standards | CE Marked, cCSAus Certified, cULus Listed , RoHS Complaint |
| UNSPSC | 39121528 |
| UPC 11 | 66248825965 |
| UPC 12 | 66248825965 |
| Voltage Rating | 24/240 VAC |
| Stock Status | NORMALLY STOCKED |
| Brand | Banner® |
| Manufacturer | Banner Engineering Corp. |
| Output Type | Switch |
| Response Time | 8 ms |
| Sensing Beam | Infrared |
| Sensing Range | 380 mm |
| Shape | Rectangular |
| Rectangular with M18 barrel housing style; Protected against transient voltages, false pulse on power-up; Controls are located on the rear panel of the sensor and are protected by a gasketed, clear acrylic cover; Totally encapsulated, O-ring sealing, stainless steel screws construction; Overload conditions can destroy ac MINI-BEAM sensors. Directly wiring sensor without load series, across hot and neutral will damage sensor (except emitter models); Low-voltage use requires careful analysis of the load to determine if the sensor's leakage current or on-state voltage will interfere with proper operation of the load; The false-pulse protection feature may cause momentary drop-out of the load when the sensor is wired in series or parallel with mechanical switch contacts; Controls are located on rear panel of sensor and protected by a gasketed, clear acrylic co |
| Protected against transient voltages, false pulse on power-up |
| Controls are located on the rear panel of the sensor and are protected by a gasketed, clear acrylic cover |
| Totally encapsulated, O-ring sealing, stainless steel screws construction |
| Overload conditions can destroy ac MINI-BEAM sensors. Directly wiring sensor without load series, across hot and neutral will damage sensor (except emitter models) |
| Low-voltage use requires careful analysis of the load to determine if the sensors leakage current or on-state voltage will interfere with proper operation of the load |
| The false-pulse protection feature may cause momentary drop-out of the load when the sensor is wired in series or parallel with mechanical switch contacts |
| Controls are located on rear panel of sensor and protected by a gasketed, clear acrylic cove |
| 5 mA minimum load current, 300 mA to 50 deg C, 100 mA to 70 deg C maximum steady-state load capability, 3 A for 1 sec (non-repetitive), 10 A For 1 cycle (non-repetitive) inrush capability |
| Less than or equal to 5 V at 300 mA load and less than or equal to 10 V at 15 mA load on-state voltage drop |
| Self-contained diffuse mode photoelectric sensor |
| Less than 1.7 mA off-state output leakage |
| 8 ms on/off response time |
| 880 nm infrared LED sensing beam |
| Acrylic lens, 90 percent at 50 deg C (non-condensing) relative humidity |
| 2 m cable connection |
| Thermoplastic reinforced VALOX enclosure |
| Light/dark operate, solid-state AC switch output |
| 18 mm barrel diameter |
| Self-Contained |