Banner Engineering IM-T-9A IM-T Interface Module, 84 mm H x 22-1/2 mm W x 118 mm D, 24 VAC/VDC, 300 mA, 3NO
Banner Engineering IM-T-9A IM-T Interface Module, 84 mm H x 22-1/2 mm W x 118 mm D, 24 VAC/VDC, 300 mA, 3NO
SKU132133
MFGR #IM-T-9A
Your Cost: $193.02/ea
List: Banner Engineering Interface Module, Series: IM-T, 84 mm H x 22-1/2 mm W x 118 mm D, 24 VAC/VDC, 300 mA, Simultaneous/Concurrent Input, 3NO, 300 mA at 60 VAC Contact, Audible Alarm/LED Indicator, IP20/NEMA 1, 100000 Operating Cycles, DIN Rail Mount
Banner Engineering Interface Module, Series: IM-T, 84 mm H x 22-1/2 mm W x 118 mm D, 24 VAC/VDC, 300 mA, Simultaneous/Concurrent Input, 3NO, 300 mA at 60 VAC Contact, Audible Alarm/LED Indicator, IP20/NEMA 1, 100000 Operating Cycles, DIN Rail Mount
Catalog Number IM-T-9A Contact Rating 300 mA at 60 VAC Country of Origin US Enclosure Rating IP20/NEMA 1 Gross Weight Per Pack 0.5500 lb Indicator Type Audible Alarm/LED Mounting Type DIN Rail Operating Cycles 100000 Cycles Series IM-T Standards CE Marked, UL Listed UNSPSC 32151802 UPC 11 66248861425 UPC 12 66248861425 Stock Status NORMALLY STOCKED Brand BANNER® Manufacturer Banner Engineering Corp. Amperage Rating 300 mA Contact Configuration 3NO Input Type Simultaneous/Concurrent Size 84 mm H x 22-1/2 mm W x 118 mm D Voltage Rating 24 VAC//VDC Interface Modules provide isolated safety output contacts for a primary safety device (e.g., a safety light screen or safety module) which has solid-state or hard contact outputs and external device monitoring (EDM) capability; Features three normally open 6 AMP redundant-output channels; Normally closed outputs for connection to the primary safety device's monitoring input; Convenient plug-in terminal blocks; Supply protection circuitry: Protected against transient voltages; Overvoltage category: Output relay contact voltage of 1 V to 150 V AC/DC - Category III, output relay contact voltage of 151 V to 250 V AC/DC - Category II; AgNi and 5 UM gold-plated output contacts Interface modules provide isolated safety output contacts for a primary safety device which has solid-state or hard contact outputs and external device monitoring (EDM) capability Model IM-T-9A features two normally open redundant-output channels and one normally closed non-safety auxiliary output channel, all rated at 6 A Normally closed outputs for connection to the primary safety devices monitoring input 2.5 mm DIN-rail-mountable housing Convenient plug-in terminal blocks Polycarbonate primary housing 50 mA power consumption 20 ms response time 2 pollution degree Transient voltage supply protection 10 to 55 Hz at 0.35 mm vibration 50 deg C operating temperature 90% at 50 deg C relative humidity Removable terminal type 2 green LED indicators power ON, K1/K2 energized AgNi gold-flashed contacts 20000000 operations mechanical life
content loaded
content loaded
content loaded
content loaded
- Attributes
- Documents & Resources
- Features
- Substitute Products
Catalog Number | IM-T-9A |
Contact Rating | 300 mA at 60 VAC |
Country of Origin | US |
Enclosure Rating | IP20/NEMA 1 |
Gross Weight Per Pack | 0.5500 lb |
Indicator Type | Audible Alarm/LED |
Mounting Type | DIN Rail |
Operating Cycles | 100000 Cycles |
Series | IM-T |
Standards | CE Marked, UL Listed |
UNSPSC | 32151802 |
UPC 11 | 66248861425 |
UPC 12 | 66248861425 |
Stock Status | NORMALLY STOCKED |
Brand | BANNER® |
Manufacturer | Banner Engineering Corp. |
Amperage Rating | 300 mA |
Contact Configuration | 3NO |
Input Type | Simultaneous/Concurrent |
Size | 84 mm H x 22-1/2 mm W x 118 mm D |
Voltage Rating | 24 VAC//VDC |
Interface Modules provide isolated safety output contacts for a primary safety device (e.g., a safety light screen or safety module) which has solid-state or hard contact outputs and external device monitoring (EDM) capability; Features three normally open 6 AMP redundant-output channels; Normally closed outputs for connection to the primary safety device's monitoring input; Convenient plug-in terminal blocks; Supply protection circuitry: Protected against transient voltages; Overvoltage category: Output relay contact voltage of 1 V to 150 V AC/DC - Category III, output relay contact voltage of 151 V to 250 V AC/DC - Category II; AgNi and 5 UM gold-plated output contacts |
Interface modules provide isolated safety output contacts for a primary safety device which has solid-state or hard contact outputs and external device monitoring (EDM) capability |
Model IM-T-9A features two normally open redundant-output channels and one normally closed non-safety auxiliary output channel, all rated at 6 A |
Normally closed outputs for connection to the primary safety devices monitoring input |
2.5 mm DIN-rail-mountable housing |
Convenient plug-in terminal blocks |
Polycarbonate primary housing |
50 mA power consumption |
20 ms response time |
2 pollution degree |
Transient voltage supply protection |
10 to 55 Hz at 0.35 mm vibration |
50 deg C operating temperature |
90% at 50 deg C relative humidity |
Removable terminal type |
2 green LED indicators power ON, K1/K2 energized |
AgNi gold-flashed contacts |
20000000 operations mechanical life |