or to view stock quantity and your pricing.
Steiner serves territories in Northern Illinois, Northwest Indiana and Southern Wisconsin. Please for assistance if outside our sales territory.
Banner Engineering ES-FL-2A ES Series Emergency Stop Safety Module, 250 mA, 2NO-1NC Contact Form
Banner Engineering ES-FL-2A ES Series Emergency Stop Safety Module, 250 mA, 2NO-1NC Contact Form
SKU176827
MFGR #ES-FL-2A
Your Cost: $330.00/ea
Banner Engineering Emergency Stop Safety Module, Series: ES Series, 250 mA, 20 W, 50/60 Hz, 2NO-1NC, DIN Rail Mount, Fixed Terminal, NEMA 1/IP20, 0 to 50 deg C, 75 mm H x 45 mm W x 110 mm D
Banner Engineering Emergency Stop Safety Module, Series: ES Series, 250 mA, 20 W, 50/60 Hz, 2NO-1NC, DIN Rail Mount, Fixed Terminal, NEMA 1/IP20, 0 to 50 deg C, 75 mm H x 45 mm W x 110 mm D
Catalog Number ES-FL-2A Dimensions 75 mm H x 45 mm W x 110 mm D Enclosure Type NEMA 1/IP20 Frequency Rating 50/60 Hz Gross Weight Per Pack 1 lb Mounting Type DIN Rail Power Rating 20 W Series ES Series Standards CE Marked, CSA Certified, UL Listed Temperature Rating 0 to 50 °C Terminal Type Fixed UPC 11 66248846092 UPC 12 66248846092 Stock Status NONSTOCK Brand BANNER® Manufacturer Banner Engineering Corp. Amperage Rating 250 mA Contact Form 2NO-1NC Polycarbonate primary housing 40 to 100 mA at 12 to 18 VDC safety input - dual channel (dry contact), 40 to 100 mA at 12 to 18 VDC (dry contact only) safety input - reset Category 4 design rating 100000 cycles at 1000 VA electrical life 90% at 50 deg C relative humidity Simultaneous or concurrent input operation 2 NO (4 A), 1 NC non-safety (0.5 A) output configuration 10000000 operations mechanical life 25 ms response time Transient voltage/reverse polarity supply protection 24 VAC/VDC +/-15% supply voltage 10 to 55 Hz at 0.35 mm vibration One 2-channel type input 2 channels output Monitors two normally-closed emergency stop switch circuits for a contact failure or wiring fault Input monitoring circuit uses a diverse-redundant design Requires a reset routine for controlled re-application of power to the machinery as per ANSI standard B11.20-1991 Two output switching channels for connection to control-reliable power interrupt circuits Auxiliary non-safety contact for status monitoring by process controller Protected against transient voltages and reverse polarity
content loaded
content loaded
content loaded
content loaded
- Attributes
- Documents & Resources
- Features
- Substitute Products
| Catalog Number | ES-FL-2A |
| Dimensions | 75 mm H x 45 mm W x 110 mm D |
| Enclosure Type | NEMA 1/IP20 |
| Frequency Rating | 50/60 Hz |
| Gross Weight Per Pack | 1 lb |
| Mounting Type | DIN Rail |
| Power Rating | 20 W |
| Series | ES Series |
| Standards | CE Marked, CSA Certified, UL Listed |
| Temperature Rating | 0 to 50 °C |
| Terminal Type | Fixed |
| UPC 11 | 66248846092 |
| UPC 12 | 66248846092 |
| Stock Status | NONSTOCK |
| Brand | BANNER® |
| Manufacturer | Banner Engineering Corp. |
| Amperage Rating | 250 mA |
| Contact Form | 2NO-1NC |
| Polycarbonate primary housing |
| 40 to 100 mA at 12 to 18 VDC safety input - dual channel (dry contact), 40 to 100 mA at 12 to 18 VDC (dry contact only) safety input - reset |
| Category 4 design rating |
| 100000 cycles at 1000 VA electrical life |
| 90% at 50 deg C relative humidity |
| Simultaneous or concurrent input operation |
| 2 NO (4 A), 1 NC non-safety (0.5 A) output configuration |
| 10000000 operations mechanical life |
| 25 ms response time |
| Transient voltage/reverse polarity supply protection |
| 24 VAC/VDC +/-15% supply voltage |
| 10 to 55 Hz at 0.35 mm vibration |
| One 2-channel type input |
| 2 channels output |
| Monitors two normally-closed emergency stop switch circuits for a contact failure or wiring fault |
| Input monitoring circuit uses a diverse-redundant design |
| Requires a reset routine for controlled re-application of power to the machinery as per ANSI standard B11.20-1991 |
| Two output switching channels for connection to control-reliable power interrupt circuits |
| Auxiliary non-safety contact for status monitoring by process controller |
| Protected against transient voltages and reverse polarity |