Appleton® CEPI6034BC Pin and Sleeve Plug Interior, 125/250 VAC, 60 A, 4 Poles, 3 Wires

Pin & Sleeve Device Interiors
818568 MFG #: CEPI6034BC
Appleton™
290.62000 / ea
  • Application: For CPH-6034BC Plug
  • ARRA Compliant: C
  • Buy American Compliant: N
  • Catalog Number: CEPI6034BC
  • Connection: Pressure Wire Terminal
  • Country of Origin: MX
  • Currency: USD
  • EU RoHS Indicator: N
  • Gross Weight Per Pack: 0.6400 lb
  • Gross Weight per Pack Metric: 0.29
  • Gross Weight UOM Metric: kg
  • Grounding Style: Extra Pole/Shell
  • Height: 5.30 in
  • Height [Metric]: 13.4620 cm
  • Length: 4.70 in
  • Length [Metric]: 11.9380 cm
  • Maximum Cable Diameter: 1-3/8 in
  • Minimum Cable Diameter: 1/2 in
  • Phase: 3
  • Series: CEPI
  • Standard: Class I, Division 1 And 2, Groups C, D
  • Standards: ARRA Compliant
  • Type: 3-Phase Delayed-Action Grounding Style 2 Safety Construction
  • UNSPSC: 39121402
  • UPC 11: 78138174241
  • UPC 12: 781381742412
  • Width: 4.40 in
  • Width [Metric]: 11.1760 cm
  • Stock Status: NONSTOCK
  • Brand: Appleton™
  • Manufacturer: Appleton
  • Amperage Rating: 60 A
  • Connector Type: Pressure Wire
  • Number of Wires: 3
  • Voltage Rating: 125 to 250 VAC
  • Number Of Poles: 4
Appleton® Pin and Sleeve Plug Interior, 125/250 VAC, 60 A, 4 Poles, 3 Wires, 0.39 in Minimum Cable Diameter, 1-3/8 in Maximum Cable Diameter, Aluminum
QTY
  • Applications
  • Features
For CPH-6034BC Plug
Explosionproof; Rotation of plug activates switch to ON position during plug insertion and to OFF position during plug withdrawal; Powertite series non hazardous location receptacles as well as CES/CESD and EBR, EBRH, JBR, MD2SR and DBR hazardous location receptacles
Rotation of plug activates switch to On position during plug insertion and to Off position during plug withdrawal
Powertite series non hazardous location receptacles as well as CES/CESD and EBR, EBRH, JBR, MD2SR and DBR hazardous location receptacles
Delayed-action construction: Insert plug to the first stop, move the Slide-Lok slide to the right, then push the plug fully forward to lock it in place and energize the receptacle
Receptacle terminals are deeply recessed to prevent accidental touching
Constant pressure brass contacts ensure superior electrical continuity
Neoprene bushing compressed by cable collar prevents entry of water
Spring door keeps out dust when the receptacle is not in use
Insulators provide superior dielectric and mechanical strength along with minimal arc tracking
Mechanical cable clamps prevent cable strain at the plug connection