  • Application: Residential
  • ARRA Compliant: C
  • Buy American Compliant: C
  • Catalog Number: GFRBF-W
  • Country of Origin: CN
  • Currency: USD
  • Dimensions: 4.21 in H x 1.69 in W x 1.4 in D
  • EU RoHS Indicator: C
  • Grade: Residential
  • Gross Weight Per Pack: 0.3000 lb
  • Gross Weight per Pack Metric: 0.14
  • Height: 5.0000 in
  • Horsepower: 1 hp
  • Length: 8.7500 in
  • Material: Polycarbonate/Thermoplastic
  • NEMA Rating: 5-20R
  • Replaced Catalog Number: X7590-W
  • Standard: UL/CSA
  • Standards: ARRA CompliantBuy American Act CompliantRoHS CompliantUL ListedCSA Certified
  • Sub Brand: SmartlockPro®
  • Temperature Rating: -35C to +66C °C
  • Terminal Type: Back/Side Wired
  • Type: Self-test SmartLock Pro Slim GFCI
  • UNSPSC: 39121406
  • UPC 11: 07847771457
  • UPC 12: 078477714577
  • Stock Status: NORMALLY STOCKED
  • Brand: Leviton®
  • Manufacturer: Leviton Manufacturing Co., Inc.
  • Amperage Rating: 20 A
  • Color: White
  • Number of Wires: 3
  • Voltage Rating: 125 V
  • Number Of Poles: 2
Peace of mind, all the time. The SmartlockPro Self-Test GFCI tests itself even if you forget. Designed to meet the latest UL standard for auto-monitoring (self-test) our complete line of self-test GFCIs periodically conduct an automatic internal test to confirm that it can respond to a ground fault. With the slimmest profile on the market, the device allows for fast and easy installation, while Leviton's patented reset lockout mechanism prevents reset of the GFCI if it is not wired or operating correctly. The SmartlockPro Self-Test GFCI is the smart choice in ground fault circuit interrupter protection.
QTY
  • Applications
  • Features
Residential
Blank GFCI
Provides continuous ground fault protection detects and trips on actual ground fault even when self-test is being conducted
On initial power up, tests the GFCI circuit within 3 sec
Auto monitoring exceeds the UL requirement
Auto adapts and shifts to more frequent testing if potential problem is detected
Status indicator light provides simple, intuitive feedback on power and protection status as well as indication of line load reversal
Patented lockout action prevents reset if GFCI is damaged and cannot respond to a ground fault
Electronics are designed to minimize any false triggers
Reduced depth makes it easier to install in any electrical box, even shallow ones
Terminals allow for easy wiring options - back and side wire capable
External back wire clamps provide visual indication of proper wire seating
Withstands high torque and resists wire pullout
Standard brass self-grounding clip
Trip threshold meets or exceeds UL requirements for tripping time
Improved immunity to high frequency noise reduces nuisance tripping
Advanced electronics design provides superior resistance to electrical surges and over voltages
Thermoplastic face
Galvanized steel strap
Self-test, monochromatic
UL 94-V2 flammability, Back and side wired
14 - 10 AWG