Ideal® 89-608 Barrier Strip, 12-Circuit Wire Range 22 - 12 AWG; 20A/300V
Custom_Product_Images_Illustration
IDEAL®
Ideal® 89-608 Barrier Strip, 12-Circuit Wire Range 22 - 12 AWG; 20A/300V
SKU89479
MFGR #89-608
Your Cost: $15.09/ea
IDEAL® Barrier Strip, Series: 89-600, 600/400 VAC, 20/10 A, 22 to 12 AWG, 20 to 18 AWG Wire, 3.5 in-lb, Recessed Screw, 105 deg C, Nylon 6.6, 3.787 in L x 0.669 in W x 0.57 in H
IDEAL® Barrier Strip, Series: 89-600, 600/400 VAC, 20/10 A, 22 to 12 AWG, 20 to 18 AWG Wire, 3.5 in-lb, Recessed Screw, 105 deg C, Nylon 6.6, 3.787 in L x 0.669 in W x 0.57 in H
ARRA Compliant C Buy American Compliant C Catalog Number 89-608 Center Spacing 0.315 in Connection Type Recessed Screws/Tubular Contacts Country of Origin TWN Currency USD Dimensions 3.787 in L x 0.669 in W x 0.315 in H EU RoHS Indicator Y Gross Volume Per Pack 10.50 Gross Volume per Pack Metric 172.06 Gross Volume UOM CI Gross Volume UOM Metric cm3 Gross Weight Per Pack 0.0850 lb Gross Weight per Pack Metric 0.05 Gross Weight UOM Metric kg Height 0.70 in Height [Metric] 17.7800 mm Length 7.90 in Length [Metric] 20.0660 cm Material Plastic Material Composition https://www.ideadigitalcontent.com/files/11020/US_ROHS_COMPLIANCE_STATEMENT_REV_2_23_2015.PDF Material Composition Declaration https://www.ideadigitalcontent.com/files/11020/US_ROHS_COMPLIANCE_STATEMENT_REV_2_23_2015.PDF Number Of Terminals 12 Power Rating 10/20 A Series 89-600 Standard C/US UL Listed, RoHS Standards ARRA CompliantBuy American Act CompliantRoHS CompliantC/US UL ListedCSA CertifiedUL94 V-2 Flammability RatingUL Recognized Temperature Rating 221 °F Torque Rating 3.5 in-lb Type Ideal UNSPSC 39121407 UPC 11 78325089608 UPC 12 783250896080 Width 1.90 in Width [Metric] 4.8260 cm Stock Status NORMALLY STOCKED Brand IDEAL® Manufacturer Ideal Industries Amperage Rating 10/20 A Voltage Rating 300/400 V Wire Size 22 - 12 AWG Features: UL Recognized For 20A, 300V; CSA Certified For 10A, 400V; Torque Rating Of 3.5 In-Lbs; Recessed Screws And Tubular Contacts; UL Listed And CSA Certified; Connect Stripped Un-Terminated Solid Or Stranded Wire; Modular 12 Circuits Can Be Cut Into Smaller Sections; Plastic Housing Is UL Flame Rated To 94V-2; Rated Temperature To 105 Degrees C; Recessed Screws And Tubular Contacts Provide Added Safety And Help Prevent Short Circuits; Tubular Contacts Connect Stripped, Un-Terminated Solid Or Stranded Wire Directly To Each Contact Integrated Wire Protectors Prevent Twisting And Breakage Of Stranded Wire During Connection; Modular 12-Circuit Design Can Be Cut Into Smaller Sections,Or Stacked End-To-End Rugged Nylon Construction, UL 94V2; Operating Temperature Rated To 105°C (221°F) Recessed Screws And Tubular Contacts Provide Added Safety And Help Prevent Short Circuits Tubular Contacts Connect Stripped, Un-Terminated Solid Or Stranded Wire Directly To Each Contact Integrated Wire Protectors Prevent Twisting And Breakage Of Stranded Wire During Connection; Modular 12-Circuit Design Can Be Cut Into Smaller Sections,Or Stacked End-To-End; Rugged Nylon Construction, UL 94V2; Operating Temperature Rated To 105°C (221°F); Number Of Circuits: 12; Torque Rating: 3.500 IN-LB; Rated Temperature: 105 DEG C; Overall Height: 0.315 IN; Model: PA8DS; Electrical Ratings: 20A/300V UL to 10A/400V CSA Modular 12 circuit design can be cut into sections or stacked end to end Recessed screws and tubular contacts provide added safety and help prevent short circuits Tubular contacts connect stripped, un-terminated solid or stranded wire directly to each contact Integrated wire protectors prevent twisting and breakage of stranded wire during connection Rugged nylon construction
content loaded
content loaded
content loaded
- Attributes
- Documents & Resources
- Features
- Substitute Products
ARRA Compliant | C |
Buy American Compliant | C |
Catalog Number | 89-608 |
Center Spacing | 0.315 in |
Connection Type | Recessed Screws/Tubular Contacts |
Country of Origin | TWN |
Currency | USD |
Dimensions | 3.787 in L x 0.669 in W x 0.315 in H |
EU RoHS Indicator | Y |
Gross Volume Per Pack | 10.50 |
Gross Volume per Pack Metric | 172.06 |
Gross Volume UOM | CI |
Gross Volume UOM Metric | cm3 |
Gross Weight Per Pack | 0.0850 lb |
Gross Weight per Pack Metric | 0.05 |
Gross Weight UOM Metric | kg |
Height | 0.70 in |
Height [Metric] | 17.7800 mm |
Length | 7.90 in |
Length [Metric] | 20.0660 cm |
Material | Plastic |
Material Composition | https://www.ideadigitalcontent.com/files/11020/US_ROHS_COMPLIANCE_STATEMENT_REV_2_23_2015.PDF |
Material Composition Declaration | https://www.ideadigitalcontent.com/files/11020/US_ROHS_COMPLIANCE_STATEMENT_REV_2_23_2015.PDF |
Number Of Terminals | 12 |
Power Rating | 10/20 A |
Series | 89-600 |
Standard | C/US UL Listed, RoHS |
Standards | ARRA CompliantBuy American Act CompliantRoHS CompliantC/US UL ListedCSA CertifiedUL94 V-2 Flammability RatingUL Recognized |
Temperature Rating | 221 °F |
Torque Rating | 3.5 in-lb |
Type | Ideal |
UNSPSC | 39121407 |
UPC 11 | 78325089608 |
UPC 12 | 783250896080 |
Width | 1.90 in |
Width [Metric] | 4.8260 cm |
Stock Status | NORMALLY STOCKED |
Brand | IDEAL® |
Manufacturer | Ideal Industries |
Amperage Rating | 10/20 A |
Voltage Rating | 300/400 V |
Wire Size | 22 - 12 AWG |
Features: UL Recognized For 20A, 300V; CSA Certified For 10A, 400V; Torque Rating Of 3.5 In-Lbs; Recessed Screws And Tubular Contacts; UL Listed And CSA Certified; Connect Stripped Un-Terminated Solid Or Stranded Wire; Modular 12 Circuits Can Be Cut Into Smaller Sections; Plastic Housing Is UL Flame Rated To 94V-2; Rated Temperature To 105 Degrees C; Recessed Screws And Tubular Contacts Provide Added Safety And Help Prevent Short Circuits; Tubular Contacts Connect Stripped, Un-Terminated Solid Or Stranded Wire Directly To Each Contact Integrated Wire Protectors Prevent Twisting And Breakage Of Stranded Wire During Connection; Modular 12-Circuit Design Can Be Cut Into Smaller Sections,Or Stacked End-To-End Rugged Nylon Construction, UL 94V2; Operating Temperature Rated To 105°C (221°F) Recessed Screws And Tubular Contacts Provide Added Safety And Help Prevent Short Circuits Tubular Contacts Connect Stripped, Un-Terminated Solid Or Stranded Wire Directly To Each Contact Integrated Wire Protectors Prevent Twisting And Breakage Of Stranded Wire During Connection; Modular 12-Circuit Design Can Be Cut Into Smaller Sections,Or Stacked End-To-End; Rugged Nylon Construction, UL 94V2; Operating Temperature Rated To 105°C (221°F); Number Of Circuits: 12; Torque Rating: 3.500 IN-LB; Rated Temperature: 105 DEG C; Overall Height: 0.315 IN; Model: PA8DS; Electrical Ratings: 20A/300V UL to 10A/400V CSA |
Modular 12 circuit design can be cut into sections or stacked end to end |
Recessed screws and tubular contacts provide added safety and help prevent short circuits |
Tubular contacts connect stripped, un-terminated solid or stranded wire directly to each contact |
Integrated wire protectors prevent twisting and breakage of stranded wire during connection |
Rugged nylon construction |