3M™ 054007-42212 7690-S Cold Shrink QT-III Termination Kit, 3, For Use With Single Core Tape Shield, Wire Shield and UniShield Cable

Insulated Termination Kits
48121 MFG #: 7000031602
3M™
1018.69000 / ea
  • Alternate Catalog Number: 7693-S-4
  • Application: Outdoor
  • ARRA Compliant: X
  • Buy American Compliant: X
  • Cable Type: Tape Shield; UniShield(R); Wire Shield
  • Catalog Number: 7000031602
  • Conductor Size: 1 AWG; 1/0 AWG; 2 AWG; 2/0 AWG; 250 kcmil; 3/0 AWG; 300 kcmil; 350 kcmil; 4/0 AWG; 400 kcmil; 500 kcmil
  • Country of Origin: US
  • Currency: USD
  • EU RoHS Indicator: C
  • Expiry|Spoilage Date Applicable Indicator: Y
  • Gross Weight Per Pack: 3.6000 lb
  • Gross Weight per Pack Metric: 1.63
  • Gross Weight UOM Metric: kg
  • Harmonization Tariff Schedule Code: 8546900000
  • Height: 5.80 in
  • Height [Metric]: 14.7320 cm
  • Length: 14.40 in
  • Length [Metric]: 36.5760 cm
  • Material Composition Declaration: Contact 3M for information
  • Number Of Terminals: 1
  • Returnable: Y
  • Series: 7690-S
  • Specifications: 5 kV, 8 kV, 15 kV, 25/28 kV, 150 kV BIL-Rated, 0.72 to 1.29 in OD Cable Insulation, 12-1/4 in Max Installed Length, 2 AWG, 1 AWG, 1/0 AWG, 2/0 AWG, 3/0 AWG, 4/0 AWG, 250 kcmil, 300 kcmil, 350 kcmil, 400 kcmil, 500 kcmil Conductor Size
  • Standard: IEEE
  • Standards: ARRA, Buy American Act, RoHS Compliant, IEEE 48 Class 1
  • Type: Cold Shrink QT-III
  • UNSPSC: 39120000
  • UPC 11: 05400742212
  • UPC 12: 054007422129
  • Voltage Rating: 892.857/5,000/8,000/15,000 V
  • Width: 8.40 in
  • Width [Metric]: 21.3360 cm
  • Stock Status: NONSTOCK
  • Brand: 3M™
  • Manufacturer: 3M™
  • Color: Black
  • Number Of Pieces: 1
  • Material: Silicon Rubber
  • Suitable For Use With: Single Core Tape Shield, Wire Shield and UniShield® Cable
3M™ Cold Shrink QT-III 7620-S, 7680-S & 7690-S Series Termination Kit includes three 1-piece, 3-phase, skirted terminations. It ensures a pliable, tight seal for tape shield, wire shield and UniShield® power cables. The conjunction of high dielectric-constant material and siliconerubber insulation allows the termination to withstand voltages of 5 - 35 kV.
QTY
  • Applications
  • Features
Outdoor
Provides a void free seal to tape shield, wire shield and UniShield® power cables
High dielectric constant material regulates the distribution of electric field stress
Silicone rubber insulation offers durability and reduces leakage currents in damp conditions
UniShield®, wire shield, tape shield shielding type
Conductor size by voltage (5 kV) 300 to 500 kcmil, (8 kV) 250 to 500 kcmil, (15 kV) 2/0 AWG to 300 kcmil, (25/28 kV) 2 to 4/0 AWG
1 terminal
QL2-A-2-250 compatible lug
QL2-A-2-250 compatible lug