SKU776145
MFGR #7100035795
Your Cost: $249.58/ea
List: 3M RJS Series Rejacketing Sleeves are designed so that 3M Cold Shrink QTII and QTIII Silicone Rubber Termination applications can be used on 3/C (three conductor) medium voltage shielded power cables of tape shield, wire shield, armored and non-armored configurations. RJS Rejacketing Assemblies are a series of silicone rubber insulators incorporating an inner expandable polyester braid designed to reduce sliding friction and deliver the insulator onto the cable. Rejacketing sleeves are designed to protect the phase legs (core) of 3/C shielded power cable from exposure to moisture, corrosion, ozone, ultra-violet radiation, physical contact and other hazards that are associated with termination operating environments. Rejacketing sleeves are designed to be used in conjunction with 3M Cold Shrink Breakout Boots and Silicone Rubber Terminations.
3M RJS Series Rejacketing Sleeves are designed so that 3M Cold Shrink QTII and QTIII Silicone Rubber Termination applications can be used on 3/C (three conductor) medium voltage shielded power cables of tape shield, wire shield, armored and non-armored configurations. RJS Rejacketing Assemblies are a series of silicone rubber insulators incorporating an inner expandable polyester braid designed to reduce sliding friction and deliver the insulator onto the cable. Rejacketing sleeves are designed to protect the phase legs (core) of 3/C shielded power cable from exposure to moisture, corrosion, ozone, ultra-violet radiation, physical contact and other hazards that are associated with termination operating environments. Rejacketing sleeves are designed to be used in conjunction with 3M Cold Shrink Breakout Boots and Silicone Rubber Terminations.
Alternate Catalog Number RJS-1-1FT Application Protect shielded phase legs after jacket has been removed in preparation for terminating ARRA Compliant X Buy American Compliant X Cable Type Sleeeve Catalog Number 7100035795 Conductor Size 0.43 ? 0.60 Country of Origin US Currency USD EU RoHS Indicator C Expiry|Spoilage Date Applicable Indicator Y Gross Weight Per Pack 1.2000 lb Gross Weight per Pack Metric 0.54 Gross Weight UOM Metric kg Harmonization Tariff Schedule Code 3926909985 Height 5.60 in Height [Metric] 14.2240 cm Length 9.30 in Length [Metric] 23.6220 cm Material Composition Declaration Contact 3M for information NEMA Color Dark Gray Returnable Y Standards IEEE 48 - 1996, RoHS Complaint, VDE 0278 Type Rejacketing Sleeve UNSPSC 26121600 UPC 11 05400743099 UPC 12 054007430995 Width 7.80 in Width [Metric] 19.8120 cm Stock Status NONSTOCK Brand 3M™ Manufacturer 3M™ Color Dark Gray Protect shielded phase legs after jacket has been removed in preparation for terminating Versatile installs quickly and accommodates a wide range of cable sizes Simple hand application no need for special installation tools No torches or heat required Excellent resistance to ozone and ultra-violet radiation Good solvent resistance compatible with industry approved cable cleaners Excellent thermal stability High dry and wet insulation resistance Excellent shelf life Easy to adjust sleeve length adapts to variable equipment connection and mounting requirements Used to protect shielded phase legs (cores) of 3/C medium voltage (35 kV and less) power cables after the jacket has been removed in preparation for terminating Accommodate cable sizes ranging from 8 AWG (8 mm2) at 3.3 kV - 750 kcmil (325 mm2) at 35 kV Available in six sizes to cover cable metallic shield dia ranging from 0.43 in (10.9 mm) to 1.91 in (48.5 mm) RJS Series sleeve assemblies can be field tested using normal cable testing procedures Rejacketing sleeves are designed to protect the phase legs (core) of 3/C shielded power cable from exposure to moisture, corrosion, ozone, ultra-violet radiation, physical contact and other hazards that are associated with termination operating environments Cold Shrink QT-III and Q-TIII silicone rubber terminations can be used on 3/C (three conductor) medium voltage shielded power cables of tape shield, wire shield, armored and non-armored configuration
content loaded
content loaded
content loaded
content loaded
content loaded
- Attributes
- Documents & Resources
- Applications
- Features
- Substitute Products
Alternate Catalog Number | RJS-1-1FT |
Application | Protect shielded phase legs after jacket has been removed in preparation for terminating |
ARRA Compliant | X |
Buy American Compliant | X |
Cable Type | Sleeeve |
Catalog Number | 7100035795 |
Conductor Size | 0.43 ? 0.60 |
Country of Origin | US |
Currency | USD |
EU RoHS Indicator | C |
Expiry|Spoilage Date Applicable Indicator | Y |
Gross Weight Per Pack | 1.2000 lb |
Gross Weight per Pack Metric | 0.54 |
Gross Weight UOM Metric | kg |
Harmonization Tariff Schedule Code | 3926909985 |
Height | 5.60 in |
Height [Metric] | 14.2240 cm |
Length | 9.30 in |
Length [Metric] | 23.6220 cm |
Material Composition Declaration | Contact 3M for information |
NEMA Color | Dark Gray |
Returnable | Y |
Standards | IEEE 48 - 1996, RoHS Complaint, VDE 0278 |
Type | Rejacketing Sleeve |
UNSPSC | 26121600 |
UPC 11 | 05400743099 |
UPC 12 | 054007430995 |
Width | 7.80 in |
Width [Metric] | 19.8120 cm |
Stock Status | NONSTOCK |
Brand | 3M™ |
Manufacturer | 3M™ |
Color | Dark Gray |
Protect shielded phase legs after jacket has been removed in preparation for terminating |
Versatile installs quickly and accommodates a wide range of cable sizes |
Simple hand application no need for special installation tools |
No torches or heat required |
Excellent resistance to ozone and ultra-violet radiation |
Good solvent resistance compatible with industry approved cable cleaners |
Excellent thermal stability |
High dry and wet insulation resistance |
Excellent shelf life |
Easy to adjust sleeve length adapts to variable equipment connection and mounting requirements |
Used to protect shielded phase legs (cores) of 3/C medium voltage (35 kV and less) power cables after the jacket has been removed in preparation for terminating |
Accommodate cable sizes ranging from 8 AWG (8 mm2) at 3.3 kV - 750 kcmil (325 mm2) at 35 kV |
Available in six sizes to cover cable metallic shield dia ranging from 0.43 in (10.9 mm) to 1.91 in (48.5 mm) |
RJS Series sleeve assemblies can be field tested using normal cable testing procedures |
Rejacketing sleeves are designed to protect the phase legs (core) of 3/C shielded power cable from exposure to moisture, corrosion, ozone, ultra-violet radiation, physical contact and other hazards that are associated with termination operating environments |
Cold Shrink QT-III and Q-TIII silicone rubber terminations can be used on 3/C (three conductor) medium voltage shielded power cables of tape shield, wire shield, armored and non-armored configuration |