or to view stock quantity and your pricing.
Steiner serves territories in Northern Illinois, Northwest Indiana and Southern Wisconsin. Please for assistance if outside our sales territory.
Advance 71A7971001D Core and Coil Lamp Ballast Kit, High Pressure Sodium Lamp, 70 W, 20/208/240/277 VAC, Pulse
Custom_Product_Images_Illustration
Advance 71A7971001D Core and Coil Lamp Ballast Kit, High Pressure Sodium Lamp, 70 W, 20/208/240/277 VAC, Pulse
SKU16338
MFGR #71A7971001D
Your Cost: $141.38/ea
List: Advance HID ballasts are available to operate the wide variety of metal halide, high pressure sodium and low pressure sodium lamps available in today's marketplace. Like fluorescent, HID lamps are gas discharge lamps. Light is produced by an arc discharge between two electrodes located at opposite ends of an arc tube within the lamp's outer glass envelope. The ballast is the lamp's power supply; its purpose is to provide proper starting and operating voltage and current to initiate and sustain this arc. In addition, we now offer 120/208/240/277/480V 5-TAP core and coil ballasts for the most popular applications. 5-TAP ballasts add the 480V input lead to the Quadri-Volt designs. A Quadri-Volt or 5-TAP core and coil, along with the appropriate capacitor, ignitor (where required), mounting bracket and hardware and installation instructions are packed in a space-saving shipping carton. These "kits" eliminate the need for distributors or end-users to stock loose components of single voltage ballasts for 120, 208, 240, 277 and even some 480V applications, though single voltage kits for 480V applications will also be available.
Advance HID ballasts are available to operate the wide variety of metal halide, high pressure sodium and low pressure sodium lamps available in today's marketplace. Like fluorescent, HID lamps are gas discharge lamps. Light is produced by an arc discharge between two electrodes located at opposite ends of an arc tube within the lamp's outer glass envelope. The ballast is the lamp's power supply; its purpose is to provide proper starting and operating voltage and current to initiate and sustain this arc. In addition, we now offer 120/208/240/277/480V 5-TAP core and coil ballasts for the most popular applications. 5-TAP ballasts add the 480V input lead to the Quadri-Volt designs. A Quadri-Volt or 5-TAP core and coil, along with the appropriate capacitor, ignitor (where required), mounting bracket and hardware and installation instructions are packed in a space-saving shipping carton. These "kits" eliminate the need for distributors or end-users to stock loose components of single voltage ballasts for 120, 208, 240, 277 and even some 480V applications, though single voltage kits for 480V applications will also be available.
Alternate Catalog Number 71A7971001D Amperage Rating 0.81/0.47/0.4/0.35 A ANSI Code S62 Application Lighting Luminaire Component ARRA Compliant C Ballast Grade ANSI S62 Buy American Compliant C Catalog Number 71A7971001D Country of Origin CN Currency USD Dimensions 4 in L x 2.9 in W x 2.9 in H Dimmable No EU RoHS Indicator C Frequency Rating 60 Hz Gross Weight Per Pack 6.0000 lb Gross Weight per Pack Metric 2.54 Gross Weight UOM Metric kg Height 2.81 in Height [Metric] 7.1374 cm Length 3.94 in Length [Metric] 10.0076 cm Minimum Starting Temperature -40 °F Number Of Lamps 1 Power Factor 1.00 Standard ULR;CSA certificate;RoHS Compliant Standards ARRA CompliantBuy American Act CompliantRoHS CompliantEISA CompliantUL ListedCSA CertifiedUL Recognized Thermal Protection Class P Type Core/Coil HID Magnetic UNSPSC 39101902 UPC 11 78108779711 UPC 12 781087797112 Wattage 96 W Width 3.10 in Width [Metric] 7.8740 cm Stock Status NONSTOCK Brand Advance Manufacturer Signify Ballast Factor 1 Lamp Type High Pressure Sodium Lamp Wattage 70 W Start Type Pulse Voltage Rating 120/208/240/277 VAC Lighting Luminaire Component 0.5 mm L wire strip Stranded wire HX-HPF circuit 3 x 4 in core 12 in L wire by color Magnetic HID ballast 105 deg C igniter temperature 7 Mfd, 280 VAC, 105 deg C capacitor 1-1/4 in Dia x 2-3/4 in H capacitor 1.46/0.86/0.73/0.64 A (open circuit), 0.85/0.51/0.43/0.39 A (starting), 0.6 to 0.95/0.35 to 0.6, 0.3 to 0.5, 0.25 to 0.4 A (short circuit), 2.1 to 2.45 A secondary short circuit current Constant wattage deviation within trapezoid Remote wiring configuration allowed 2 ft ballast lamp distance remote wiring
content loaded
content loaded
content loaded
content loaded
content loaded
- Attributes
- Documents & Resources
- Applications
- Features
- Substitute Products
Alternate Catalog Number | 71A7971001D |
Amperage Rating | 0.81/0.47/0.4/0.35 A |
ANSI Code | S62 |
Application | Lighting Luminaire Component |
ARRA Compliant | C |
Ballast Grade | ANSI S62 |
Buy American Compliant | C |
Catalog Number | 71A7971001D |
Country of Origin | CN |
Currency | USD |
Dimensions | 4 in L x 2.9 in W x 2.9 in H |
Dimmable | No |
EU RoHS Indicator | C |
Frequency Rating | 60 Hz |
Gross Weight Per Pack | 6.0000 lb |
Gross Weight per Pack Metric | 2.54 |
Gross Weight UOM Metric | kg |
Height | 2.81 in |
Height [Metric] | 7.1374 cm |
Length | 3.94 in |
Length [Metric] | 10.0076 cm |
Minimum Starting Temperature | -40 °F |
Number Of Lamps | 1 |
Power Factor | 1.00 |
Standard | ULR;CSA certificate;RoHS Compliant |
Standards | ARRA CompliantBuy American Act CompliantRoHS CompliantEISA CompliantUL ListedCSA CertifiedUL Recognized |
Thermal Protection | Class P |
Type | Core/Coil HID Magnetic |
UNSPSC | 39101902 |
UPC 11 | 78108779711 |
UPC 12 | 781087797112 |
Wattage | 96 W |
Width | 3.10 in |
Width [Metric] | 7.8740 cm |
Stock Status | NONSTOCK |
Brand | Advance |
Manufacturer | Signify |
Ballast Factor | 1 |
Lamp Type | High Pressure Sodium |
Lamp Wattage | 70 W |
Start Type | Pulse |
Voltage Rating | 120/208/240/277 VAC |
Lighting Luminaire Component |
0.5 mm L wire strip |
Stranded wire |
HX-HPF circuit |
3 x 4 in core |
12 in L wire by color |
Magnetic HID ballast |
105 deg C igniter temperature |
7 Mfd, 280 VAC, 105 deg C capacitor |
1-1/4 in Dia x 2-3/4 in H capacitor |
1.46/0.86/0.73/0.64 A (open circuit), 0.85/0.51/0.43/0.39 A (starting), 0.6 to 0.95/0.35 to 0.6, 0.3 to 0.5, 0.25 to 0.4 A (short circuit), 2.1 to 2.45 A secondary short circuit current |
Constant wattage deviation within trapezoid |
Remote wiring configuration allowed |
2 ft ballast lamp distance remote wiring |