Banner Engineering Multi-Beam® PBB 3/4-Wire Power Block, Photoelectric Sensor, 210 to 250 VAC
Banner Engineering Multi-Beam® PBB 3/4-Wire Power Block, Photoelectric Sensor, 210 to 250 VAC
SKU139176
MFGR #PBB
Your Cost: $141.66/ea
List: These power blocks are the most commonly used for ac operation. As the typical hookup shows, they are intended to switch the same ac voltage as is used to power the MULTI-BEAM. However, the output of all four blocks is rated for 250V ac maximum, and all can switch a voltage which is different than the supply as long as both ac circuits share a common neutral. For example, a PBA could switch a 24V ac door chime, etc. Observe local codes when mixing ac voltages in a wiring chamber. These blocks are designed to handle the inrush current of ac inductive loads like motor starters and solenoids. The "holding current" specification of any inductive load should not exceed the 750mA output rating. There is no minimum load requirement. These power blocks will interface directly to all ac programmable controller inputs. All contain built-in transient suppression to prevent false turn-on or damage from inductive loads and line "spikes". Outputs of multiple power blocks may be wired in series or parallel for "AND" and "OR" logic functions.
These power blocks are the most commonly used for ac operation. As the typical hookup shows, they are intended to switch the same ac voltage as is used to power the MULTI-BEAM. However, the output of all four blocks is rated for 250V ac maximum, and all can switch a voltage which is different than the supply as long as both ac circuits share a common neutral. For example, a PBA could switch a 24V ac door chime, etc. Observe local codes when mixing ac voltages in a wiring chamber. These blocks are designed to handle the inrush current of ac inductive loads like motor starters and solenoids. The "holding current" specification of any inductive load should not exceed the 750mA output rating. There is no minimum load requirement. These power blocks will interface directly to all ac programmable controller inputs. All contain built-in transient suppression to prevent false turn-on or damage from inductive loads and line "spikes". Outputs of multiple power blocks may be wired in series or parallel for "AND" and "OR" logic functions.
Catalog Number PBB Connection Type Cable Country of Origin US Gross Weight Per Pack 0.2560 lb Standards CE Marked, CSA Approval, cULus Listed Suitable For Use With Multi-Beam® Compact Modular Photoelectric Sensors Type 3/4-Wire UPC 11 66248816387 UPC 12 66248816387 Stock Status NONSTOCK Brand BANNER® Manufacturer Banner Engineering Corp. Output Type SPST Solid State Switch Sensor Type Photoelectric Voltage Rating 210 to 250 VAC 50/60 Hz input 3/4 A maximum (derated to 1/2 A at 70 deg C) output 10 A for 1 sec or 30 A for one AC cycle (non-repeating) maximum inrush Less than 10 VAC at full load on-state voltage drop Less than 100 mA off-state leakage current Add 8.3 millisecond to the off-time response of the scanner block Range depends on sensor Wiring chamber 2 m length cable connection
content loaded
content loaded
content loaded
content loaded
- Attributes
- Documents & Resources
- Features
- Substitute Products
Catalog Number | PBB |
Connection Type | Cable |
Country of Origin | US |
Gross Weight Per Pack | 0.2560 lb |
Standards | CE Marked, CSA Approval, cULus Listed |
Suitable For Use With | Multi-Beam® Compact Modular Photoelectric Sensors |
Type | 3/4-Wire |
UPC 11 | 66248816387 |
UPC 12 | 66248816387 |
Stock Status | NONSTOCK |
Brand | BANNER® |
Manufacturer | Banner Engineering Corp. |
Output Type | SPST Solid State Switch |
Sensor Type | Photoelectric |
Voltage Rating | 210 to 250 VAC |
50/60 Hz input |
3/4 A maximum (derated to 1/2 A at 70 deg C) output |
10 A for 1 sec or 30 A for one AC cycle (non-repeating) maximum inrush |
Less than 10 VAC at full load on-state voltage drop |
Less than 100 mA off-state leakage current |
Add 8.3 millisecond to the off-time response of the scanner block |
Range depends on sensor |
Wiring chamber |
2 m length cable connection |