Telemecanique XCSE5331 Preventa® Rectangular Turret Head Safety Interlock Switch, 300 VAC, 110/120 VDC, 6 A, 50/60 Hz, 7 W Power Rating, 3 Poles
Custom_Product_Images_Illustration
Telemecanique XCSE5331 Preventa® Rectangular Turret Head Safety Interlock Switch, 300 VAC, 110/120 VDC, 6 A, 50/60 Hz, 7 W Power Rating, 3 Poles
SKUPDW~6422010
MFGR #XCSE5331
Your Cost: $1,058.56/ea
Telemecanique Preventa® Safety Interlock Switch, Rectangular Turret Head, Series: XCSE, 300 VAC, 110/120 VDC, 6 A, 50/60 Hz, 7 W, 1NO-1NC, 2NO-1NC, 3 A at 120 VAC/1.5 A at 240 VAC/0.55 A at 125 VDC/0.27 A at 250 VDC Contact, 3 Pole, Slow Break/Break Before Make, Key Actuator, Terminal, NEMA 4/4X/12/IP67, Threaded Mount, 98 mm W x 44 mm D x 146 mm H, 10 cycles/min Operating Cycles, -25 to 40 deg C Operating, Zamak
Telemecanique Preventa® Safety Interlock Switch, Rectangular Turret Head, Series: XCSE, 300 VAC, 110/120 VDC, 6 A, 50/60 Hz, 7 W, 1NO-1NC, 2NO-1NC, 3 A at 120 VAC/1.5 A at 240 VAC/0.55 A at 125 VDC/0.27 A at 250 VDC Contact, 3 Pole, Slow Break/Break Before Make, Key Actuator, Terminal, NEMA 4/4X/12/IP67, Threaded Mount, 98 mm W x 44 mm D x 146 mm H, 10 cycles/min Operating Cycles, -25 to 40 deg C Operating, Zamak
Action Slow Break/Break Before Make Actuator Key Actuator Type Key Alternate Catalog Number XCSE5331 Application KEY OPERATED TURRET HEAD ARRA Compliant N Buy American Compliant N Catalog Number XCSE5331 Connection Terminal 1 x 0.5...2 x 1.5 mm² with or without cable end Connection Type Terminal Contact Configuration 1NO-1NC, 2NO-1NC Contact Rating 3 A at 120 VAC/1.5 A at 240 VAC/0.55 A at 125 VDC/0.27 A at 250 VDC Country of Origin FR Currency USD Enclosure NEMA 4/4X/12 - IP67 Enclosure Type NEMA 4/4X/12/IP67 Environmental Conditions WATER TIGHT, DUST TIGHT AND CORROSION RESISTANT (INDOOR/OUTDOOR) EU RoHS Indicator Y Gross Volume Per Pack 59.40 Gross Volume per Pack Metric 973.39 Gross Volume UOM CI Gross Volume UOM Metric cm3 Gross Weight Per Pack 2.8700 lb Gross Weight per Pack Metric 1.30 Gross Weight UOM Metric kg Harmonization Tariff Schedule Code 8536509055 Height 5.7000 in Height [Metric] 5.7000 cm Item Group 22411 Length 15.5000 in Length [Metric] 15.5000 cm Material Zamak Material Composition Declaration https://checkaproduct.se.com/DistantRequestDispatcher.aspx?action=export&pid=859168&lang=en-us Mounting Type Threaded Number Of Poles 3 Operating Cycles 10 Operating Temperature -25 to 40 Returnable N Series XCSE Size 98 mm W x 44 mm D x 146 mm H Standard 10 GN 11 MS IEC 60068-2-27,5 GN 10-500 HZ)IEC 60068-2-6,CSA-UL,EN/IEC 60204-1-UL 508-EN/ISO 12100-CSA C22.2 NO 14-EN 1088/ISO 14119-EN/IEC 60947-5-1,IP67 EN/IEC 60529 AND EN/IEC 60947-5-1,CLASS I EN/IEC 61140 Sub Brand XCSE Type Rectangular Turret Head UNSPSC 39122213 UPC 11 785901850151 UPC 12 785901850151 Warranty Description Contractual Warranty:18 months Width 11.4000 in Width [Metric] 11.4000 cm Brand Telemecanique Sensors Manufacturer Telemecanique Sensors Amperage Rating 6 A Frequency Rating 50/60 Power Rating 7 Voltage Rating 300 VAC, 110/120 VDC KEY OPERATED TURRET HEAD for guard open/guard closed and locked 2 LEDs (green or orange);Locking on de-energisation and unlocking on energisation of solenoid;Overvoltage protection signalling circuit Guard open/guard closed and locked 2 LEDs green or orange, locking on de-energization and unlocking on energization of solenoid, overvoltage protection signaling circuit
content loaded
content loaded
content loaded
content loaded
content loaded
- Attributes
- Documents & Resources
- Applications
- Features
- Substitute Products
| Action | Slow Break/Break Before Make |
| Actuator | Key |
| Actuator Type | Key |
| Alternate Catalog Number | XCSE5331 |
| Application | KEY OPERATED TURRET HEAD |
| ARRA Compliant | N |
| Buy American Compliant | N |
| Catalog Number | XCSE5331 |
| Connection | Terminal 1 x 0.5...2 x 1.5 mm² with or without cable end |
| Connection Type | Terminal |
| Contact Configuration | 1NO-1NC, 2NO-1NC |
| Contact Rating | 3 A at 120 VAC/1.5 A at 240 VAC/0.55 A at 125 VDC/0.27 A at 250 VDC |
| Country of Origin | FR |
| Currency | USD |
| Enclosure | NEMA 4/4X/12 - IP67 |
| Enclosure Type | NEMA 4/4X/12/IP67 |
| Environmental Conditions | WATER TIGHT, DUST TIGHT AND CORROSION RESISTANT (INDOOR/OUTDOOR) |
| EU RoHS Indicator | Y |
| Gross Volume Per Pack | 59.40 |
| Gross Volume per Pack Metric | 973.39 |
| Gross Volume UOM | CI |
| Gross Volume UOM Metric | cm3 |
| Gross Weight Per Pack | 2.8700 lb |
| Gross Weight per Pack Metric | 1.30 |
| Gross Weight UOM Metric | kg |
| Harmonization Tariff Schedule Code | 8536509055 |
| Height | 5.7000 in |
| Height [Metric] | 5.7000 cm |
| Item Group | 22411 |
| Length | 15.5000 in |
| Length [Metric] | 15.5000 cm |
| Material | Zamak |
| Material Composition Declaration | https://checkaproduct.se.com/DistantRequestDispatcher.aspx?action=export&pid=859168&lang=en-us |
| Mounting Type | Threaded |
| Number Of Poles | 3 |
| Operating Cycles | 10 |
| Operating Temperature | -25 to 40 |
| Returnable | N |
| Series | XCSE |
| Size | 98 mm W x 44 mm D x 146 mm H |
| Standard | 10 GN 11 MS IEC 60068-2-27,5 GN 10-500 HZ)IEC 60068-2-6,CSA-UL,EN/IEC 60204-1-UL 508-EN/ISO 12100-CSA C22.2 NO 14-EN 1088/ISO 14119-EN/IEC 60947-5-1,IP67 EN/IEC 60529 AND EN/IEC 60947-5-1,CLASS I EN/IEC 61140 |
| Sub Brand | XCSE |
| Type | Rectangular Turret Head |
| UNSPSC | 39122213 |
| UPC 11 | 785901850151 |
| UPC 12 | 785901850151 |
| Warranty Description | Contractual Warranty:18 months |
| Width | 11.4000 in |
| Width [Metric] | 11.4000 cm |
| Brand | Telemecanique Sensors |
| Manufacturer | Telemecanique Sensors |
| Amperage Rating | 6 A |
| Frequency Rating | 50/60 |
| Power Rating | 7 |
| Voltage Rating | 300 VAC, 110/120 VDC |
| KEY OPERATED TURRET HEAD |
| for guard open/guard closed and locked 2 LEDs (green or orange);Locking on de-energisation and unlocking on energisation of solenoid;Overvoltage protection signalling circuit |
| Guard open/guard closed and locked 2 LEDs green or orange, locking on de-energization and unlocking on energization of solenoid, overvoltage protection signaling circuit |