or to view stock quantity and your pricing.
Steiner serves territories in Northern Illinois, Northwest Indiana and Southern Wisconsin. Please for assistance if outside our sales territory.
BANNER®
Banner Engineering ES-FA-9AA ES Series Emergency Stop Safety Module, 6 A, 3NO Contact Form
BANNER®
Banner Engineering ES-FA-9AA ES Series Emergency Stop Safety Module, 6 A, 3NO Contact Form
SKU64565
MFGR #ES-FA-9AA
Your Cost: $256.38/ea
List: Banner Engineering Emergency Stop Safety Module, Series: ES Series, 6 A, 2 W, 50/60 Hz, 3NO, DIN Rail Mount, Removable Terminal, NEMA 1/IP20, 0 to 50 deg C, 84 mm H x 22.5 mm W x 118 mm D
Banner Engineering Emergency Stop Safety Module, Series: ES Series, 6 A, 2 W, 50/60 Hz, 3NO, DIN Rail Mount, Removable Terminal, NEMA 1/IP20, 0 to 50 deg C, 84 mm H x 22.5 mm W x 118 mm D
Catalog Number ES-FA-9AA Country of Origin US Dimensions 84 mm H x 22.5 mm W x 118 mm D Enclosure Type NEMA 1/IP20 Frequency Rating 50/60 Hz Gross Weight Per Pack 0.5250 lb Mounting Type DIN Rail Power Rating 2 W Series ES Series Standards CE Marked, CSA Certified, UL Listed Temperature Rating 0 to 50 °C Terminal Type Removable UNSPSC 32151802 UPC 11 66248860131 UPC 12 66248860131 Stock Status NORMALLY STOCKED Brand Banner® Manufacturer Banner Engineering Corp. Amperage Rating 6 A Contact Form 3NO 0 Polycarbonate primary housing 10 to 20 mA at 12 VDC safety input - dual channel (dry contact), 20 mA at 12 VDC (dry contact only) safety input - reset, 40 to 100 mA at 24 VAC/VDC +/- 10% safety input - single channel Category 4 PLe; SIL 3 design rating 1000000 cycles at 450 VA electrical life 90% at 50 deg C relative humidity Simultaneous or concurrent input operation 3 NO (6 A) output configuration 20000000 operations mechanical life 25 ms response time Transient voltage/reverse polarity supply protection 24 VAC/VDC +/- 10% supply voltage 10 to 55 Hz at 0.35 mm vibration AgNi 5 um gold-plated contacts 2 pollution degree 250 ms recovery time Monitors emergency stop devices, such as palm buttons and rope/cable pulls, and positive-opening safety switches used for guard/gate interlocking The ES-FA-9AA has three normally open output switching channels for connection to control-reliable power interrupt circuits Automatic reset or monitored manual reset For use in functional stop category 0 applications per ANSI NFPA 79 and IEC/EN60204-1 6 or 7 amp safety output contacts, depending on mode
content loaded
content loaded
content loaded
content loaded
- Attributes
- Documents & Resources
- Features
- Substitute Products
Catalog Number | ES-FA-9AA |
Country of Origin | US |
Dimensions | 84 mm H x 22.5 mm W x 118 mm D |
Enclosure Type | NEMA 1/IP20 |
Frequency Rating | 50/60 Hz |
Gross Weight Per Pack | 0.5250 lb |
Mounting Type | DIN Rail |
Power Rating | 2 W |
Series | ES Series |
Standards | CE Marked, CSA Certified, UL Listed |
Temperature Rating | 0 to 50 °C |
Terminal Type | Removable |
UNSPSC | 32151802 |
UPC 11 | 66248860131 |
UPC 12 | 66248860131 |
Stock Status | NORMALLY STOCKED |
Brand | Banner® |
Manufacturer | Banner Engineering Corp. |
Amperage Rating | 6 A |
Contact Form | 3NO |
0 |
Polycarbonate primary housing |
10 to 20 mA at 12 VDC safety input - dual channel (dry contact), 20 mA at 12 VDC (dry contact only) safety input - reset, 40 to 100 mA at 24 VAC/VDC +/- 10% safety input - single channel |
Category 4 PLe; SIL 3 design rating |
1000000 cycles at 450 VA electrical life |
90% at 50 deg C relative humidity |
Simultaneous or concurrent input operation |
3 NO (6 A) output configuration |
20000000 operations mechanical life |
25 ms response time |
Transient voltage/reverse polarity supply protection |
24 VAC/VDC +/- 10% supply voltage |
10 to 55 Hz at 0.35 mm vibration |
AgNi 5 um gold-plated contacts |
2 pollution degree |
250 ms recovery time |
Monitors emergency stop devices, such as palm buttons and rope/cable pulls, and positive-opening safety switches used for guard/gate interlocking |
The ES-FA-9AA has three normally open output switching channels for connection to control-reliable power interrupt circuits |
Automatic reset or monitored manual reset |
For use in functional stop category 0 applications per ANSI NFPA 79 and IEC/EN60204-1 |
6 or 7 amp safety output contacts, depending on mode |