or to view stock quantity and your pricing.
Steiner serves territories in Northern Illinois, Northwest Indiana and Southern Wisconsin. Please for assistance if outside our sales territory.
BANNER®
Banner Engineering ATK-VP6Q5 Duo-Touch® AT Series Safety Control Module Kit, 150 mA, 4 Pins, 2NO Contact Form
BANNER®
Banner Engineering ATK-VP6Q5 Duo-Touch® AT Series Safety Control Module Kit, 150 mA, 4 Pins, 2NO Contact Form
SKU142063
MFGR #ATK-VP6Q5
Your Cost: $742.55/ea
List: Banner Engineering Duo-Touch® Safety Control Module Kit, Series: AT Series, 150 mA, 3 W, 50/60 Hz, 2NO, 4 Pins, DIN Rail Mount, Removable Terminal, NEMA 1/IP20, 0 to 50 deg C, 84 mm H x 22.5 mm W x 118 mm D
Banner Engineering Duo-Touch® Safety Control Module Kit, Series: AT Series, 150 mA, 3 W, 50/60 Hz, 2NO, 4 Pins, DIN Rail Mount, Removable Terminal, NEMA 1/IP20, 0 to 50 deg C, 84 mm H x 22.5 mm W x 118 mm D
Catalog Number ATK-VP6Q5 Country of Origin US Dimensions 84 mm H x 22.5 mm W x 118 mm D Enclosure Type NEMA 1/IP20 Frequency Rating 50/60 Hz Gross Weight Per Pack 1.7000 lb Mounting Type DIN Rail Power Rating 3 W Series AT Series Standards CE Marked Temperature Rating 0 to 50 °C Terminal Type Removable UPC 11 66248864292 UPC 12 66248864292 Stock Status NONSTOCK Brand Banner® Manufacturer Banner Engineering Corp. Amperage Rating 150 mA Contact Form 2NO Number of Pins 4 Polycarbonate primary housing 25 mA at 24 VDC (1 NO/1 NC per channel) safety input - dual channel (dry contact), 25 mA at 24 VDC (1 complimentary PNP pair per channel) safety input - dual channel (solid-state) Type IIIc; Category 4; Ple; SIL 3 design rating 1000000 cycles at 250 VA electrical life 90% at 50 deg C relative humidity Simultaneous <500 ms (500 ms typical) input operation 2 NO (6 A) output configuration 20000000 operations mechanical life 35 ms response time Transient voltage/reverse polarity supply protection 24 VAC/VDC +/-15% supply voltage 10 to 55 Hz at 0.35 mm vibration 2 pollution degree AgNi 5 um gold-plated contacts 4-pin euro quick disconnect connection Solid-state STB touch buttons Modules work with banner stb self-checking touch buttons or can be retrofitted with existing mechanical palm buttons to create a complete, ergonomic two-hand control system To ensure OSHA/ANSI Control Reliability, modules have a diverse-redundant microcontroller circuit and multiple redundant, force-guided (mechanically linked) output contacts Anti-tie down logic requires that both touch buttons are activated within one-half second or less of each other Designed to meet Category 4 per ISO 13849-1 (EN 954-1) and functional Type IIIC two-hand control per ISO 13851 (EN 574)
content loaded
content loaded
content loaded
- Attributes
- Features
- Substitute Products
Catalog Number | ATK-VP6Q5 |
Country of Origin | US |
Dimensions | 84 mm H x 22.5 mm W x 118 mm D |
Enclosure Type | NEMA 1/IP20 |
Frequency Rating | 50/60 Hz |
Gross Weight Per Pack | 1.7000 lb |
Mounting Type | DIN Rail |
Power Rating | 3 W |
Series | AT Series |
Standards | CE Marked |
Temperature Rating | 0 to 50 °C |
Terminal Type | Removable |
UPC 11 | 66248864292 |
UPC 12 | 66248864292 |
Stock Status | NONSTOCK |
Brand | Banner® |
Manufacturer | Banner Engineering Corp. |
Amperage Rating | 150 mA |
Contact Form | 2NO |
Number of Pins | 4 |
Polycarbonate primary housing |
25 mA at 24 VDC (1 NO/1 NC per channel) safety input - dual channel (dry contact), 25 mA at 24 VDC (1 complimentary PNP pair per channel) safety input - dual channel (solid-state) |
Type IIIc; Category 4; Ple; SIL 3 design rating |
1000000 cycles at 250 VA electrical life |
90% at 50 deg C relative humidity |
Simultaneous <500 ms (500 ms typical) input operation |
2 NO (6 A) output configuration |
20000000 operations mechanical life |
35 ms response time |
Transient voltage/reverse polarity supply protection |
24 VAC/VDC +/-15% supply voltage |
10 to 55 Hz at 0.35 mm vibration |
2 pollution degree |
AgNi 5 um gold-plated contacts |
4-pin euro quick disconnect connection |
Solid-state STB touch buttons |
Modules work with banner stb self-checking touch buttons or can be retrofitted with existing mechanical palm buttons to create a complete, ergonomic two-hand control system |
To ensure OSHA/ANSI Control Reliability, modules have a diverse-redundant microcontroller circuit and multiple redundant, force-guided (mechanically linked) output contacts |
Anti-tie down logic requires that both touch buttons are activated within one-half second or less of each other |
Designed to meet Category 4 per ISO 13849-1 (EN 954-1) and functional Type IIIC two-hand control per ISO 13851 (EN 574) |