Banner Engineering UM-FA-9A UM-FA Universal Input Safety Module

Control Relays
553300 MFG #: UM-FA-9A
BANNER®
254.84000 / ea
  • Catalog Number: UM-FA-9A
  • Country of Origin: UA
  • Dimensions: 84 mm H x 22.5 mm W x 118 mm D
  • Enclosure Type: IP20
  • Gross Weight Per Pack: 1 lb
  • Power Rating: 2 W
  • Series: UM-FA
  • Standards: CE Marked, UL Listed
  • Temperature Rating: 50 °C
  • Terminal Type: Removal
  • UNSPSC: 39121552
  • UPC 11: 66248881227
  • UPC 12: 66248881227
  • Stock Status: NONSTOCK
  • Brand: BANNER®
  • Manufacturer: Banner Engineering Corp.
Banner Engineering Universal Input Safety Module, Series: UM-FA, 2 W, Removal Terminal, IP20, 50 deg C, 84 mm H x 22.5 mm W x 118 mm D
QTY
  • Features
Monitors a wide variety of safety and non-safety input devices; Optical-based safeguarding devices, such as safety laser scanners; Positive-opening safety switches used for guard interlocking; Emergency-stop devices, such as palm buttons and rope/cable pulls; Standard sensors for non-safety applications, such as photoelectric monitoring position or end-of-travel; The safety inputs can monitor 24 VDC solid-state (PNP) outputs in single-channel or dual-channel hookup,24 VDC source that is switched by hard/relay contacts in single-channel or dual-channel hookup, Hard/relay contacts in a dual-channel hookup using terminals S11-S12 and S21-S22; Design complies with standards ANSI B11.19control reliability, ISO 13850 (EN418), and ISO 13849-1 (EN954-1) Category 4; Safety integrity level SIL 3 per IEC 61508/IEC 62061; Category 4 performance level PL e per ISO 13849-1; Pl
Monitors a wide variety of safety and non-safety input devices
Optical-based safe guarding devices, such as safety laser scanners
Positive-opening safety switches used for guard interlocking
Emergency-stop devices, such as palm buttons and rope/cable pulls
Standard sensors for non-safety applications, such as photoelectric monitoring position or end-of-travel
Three normally open (NO) output switching channels for connection to control-reliable power interrupt circuits
Automatic reset or monitored manual reset, depending on hookup
Safety Integrity level SIL 3 per IEC 61508/IEC 62061
Category 4 performance level Ple per ISO 13849-1
For use in functional stop category 0 applications per ANSI NFPA 79 and IEC/EN 60204-1
Plug-In terminal blocks
10 to 20 mA at 12 VDC safety input dual channel (dry contact)
5 to 20 mA at 18 to 28 VDC (PNP) safety input dual channel (solid-state)
40 to 100 mA at 24 VAC/DC +/-10% safety input reset
40 to 100 mA at 24 VAC/DC +/-10% safety input signal channel
1000000 at 450 VA electrical life (cycles at VA)
NEMA 1 rating
90% at 50 deg C relative humidity
Simultaneous or concurrent input operation
250 ms recovery time