Schneider Electric TESYS™ LU2B12FU Reversing Power Base, For Use With Combination Motor Starters
Custom_Product_Images_Illustration
Schneider Electric TESYS™ LU2B12FU Reversing Power Base, For Use With Combination Motor Starters
SKU572399
MFGR #LU2B12FU
Your Cost: $517.41/ea
List: Schneider Electric LU2B12FU 12A SELF-PR.REV.STR W/TERMS- LUCFU,-25C to 70C,0.5HP115VAC - 2HP230VAC 3HP200/230VAC - 7.5HP460VAC - 10HP575/600VAC,110/240V,12A Max,3,40-60hz,600VAC,Determined by control unit,Din Rail or panel mount,Manual (Auto with accessories),Motor Starter Power Base,Open,Reversing simple motor starter. 120VAC control, with signaling contacts,Screw Clamp Terminals,TeSys,Tesys U simple motor starter, Reversing starter base,UL Listed - CSA Certified - CE Marked
Schneider Electric LU2B12FU 12A SELF-PR.REV.STR W/TERMS- LUCFU,-25C to 70C,0.5HP115VAC - 2HP230VAC 3HP200/230VAC - 7.5HP460VAC - 10HP575/600VAC,110/240V,12A Max,3,40-60hz,600VAC,Determined by control unit,Din Rail or panel mount,Manual (Auto with accessories),Motor Starter Power Base,Open,Reversing simple motor starter. 120VAC control, with signaling contacts,Screw Clamp Terminals,TeSys,Tesys U simple motor starter, Reversing starter base,UL Listed - CSA Certified - CE Marked
Alternate Catalog Number LU2B12FU Application TESYS U SIMPLE MOTOR STARTER, REVERSING STARTER BASE ARRA Compliant N Buy American Compliant N Catalog Number LU2B12FU Connection Screw clamp terminals Country of Origin FR Currency USD Dimensions 8.82 in H x 1.77 in W x 4.96 in D EU RoHS Indicator Y Gross Volume Per Pack 132.00 Gross Volume per Pack Metric 2163.08 Gross Volume UOM CI Gross Volume UOM Metric cm3 Gross Weight Per Pack 2.8700 lb Gross Weight per Pack Metric 1.30 Gross Weight UOM Metric kg Harmonization Tariff Schedule Code 8536304000 Height 25.5000 in Height [Metric] 25.5000 cm Item Group 22396 Length 15.3000 in Length [Metric] 15.3000 cm Material Composition Declaration https://checkaproduct.se.com/DistantRequestDispatcher.aspx?action=export&pid=640420&lang=en-us Motor Size 110 to 240 VAC/VDC, 12 A, 1.7/2 W, 50/60 Hz, 3-Poles, 1NO-1NC Motor Type Combination Motor Starters Mounting DIN RAIL OR PANEL MOUNT Number Of Poles 3 Power Supply 110/240V Reset Type MANUAL (AUTO WITH ACCESSORIES) Returnable Y Series LU2B Size 126 MM,224 MM,45 MM Standard UL LISTED - CSA CERTIFIED - CE MARKED Standards ABS, ASEFA, ATEX, BV, CCC Certified, CSA C22.2 No. 14 Type E, DNV Certified, EN 60947-6-2, GL, GOST Certified, IEC 60947-6-2, LROS Certified, UL 508 Sub Brand TESYS Substitute Product Catalog Number GVAPB65 Type Self-Protected UNSPSC 39121521 UPC 11 78590120254 UPC 12 785901202547 Voltage Rating 600 VAC Warranty Description Contractual Warranty:18 months Width 5.5000 in Width [Metric] 5.5000 cm Stock Status NONSTOCK Brand Schneider Electric Manufacturer Schneider Electric Color 8.82 in H x 1.77 in W x 4.96 in D Specifications 110 to 240 VAC/VDC, 12 A, 1.7/2 W, 50/60 Hz, 3-Poles, 1NO-1NC Suitable For Use With Combination Motor Starters TESYS U SIMPLE MOTOR STARTER, REVERSING STARTER BASE REVERSING SIMPLE MOTOR STARTER. 120VAC CONTROL, WITH SIGNALING CONTACTS Suitability for isolation 10 kA 500 V, 4 kA 690 V, 50 kA 230 V, 50 kA 440 V rated service breaking capacity 1000 mA at 110 to 220 VDC I maximum while closing, 1000 mA at 110 to 240 VAC I maximum while closing typical current consumption 150 ms with change of direction power circuit, 35 ms opening with LUCA, LUCB, LUCC, LUCD, LUCM control circuit, 70 ms closing with LUCA, LUCB, LUCC, LUCD control circuit, 75 ms closing with LUCM control circuit, 75 ms without change of direction power circuit operating time, 15 ms DC network duration of inrush phase 15000000 cycles mechanical durability, 60 cycles/min operating rate, 6 kV conforming to IEC 60947-6-2 rated impulse withstand voltage, 600 V conforming to CSA C22.2 No 14, 600 V conforming to UL 508, 690 V conforming to IEC 60947-1 3 rated insulation voltage Control circuit: 7.08-10.62 lbf.in- with screwdriver 0.2 in flat, control circuit: 7.08-10.62 lbf.in - with screwdriver 0.2 in Philips no 1, power circuit: 16.81-22.12 lbf.in- with screwdriver 0.24 in flat, power circuit: 16.81-22.12 lbf.in - with screwdriver 0.24 in Philips no 2 tightening torque 2 W for control circuit with LUCA, LUCB, LUCC, LUCD, 1.7 W for control circuit with LUCM heat dissipation IP20 front panel and wired terminals conforming to IEC 60947-1, IP20 other faces conforming to IEC 60947-1, IP40 front panel outside connection zone conforming to IEC 60947-1 IP degree of protection TH conforming to IEC 60068 protective treatment 1 kV serial mode conforming to IEC 60947-6-2, 2 kV common mode conforming to IEC 60947-6-2 non-dissipating shock wave, 10 V conforming to IEC 61000-4-6 immunity to radio electric fields 1/2 hp at 1 phase 120 VAC, 2 hp at 1 phase 240 VAC, 10 hp at 3 phase 575 VAC, 3 hp at 3 phase 208 VAC, 3 hp at 3 phase 220/240 VAC, 7.5 hp at 3 phase 460 VAC power rating -13 to 140 deg F with LUCM/-13 to 158 deg F with LUCA, LUCB, LUCC, LUCD
content loaded
content loaded
content loaded
content loaded
content loaded
- Attributes
- Documents & Resources
- Applications
- Features
- Substitute Products
Alternate Catalog Number | LU2B12FU |
Application | TESYS U SIMPLE MOTOR STARTER, REVERSING STARTER BASE |
ARRA Compliant | N |
Buy American Compliant | N |
Catalog Number | LU2B12FU |
Connection | Screw clamp terminals |
Country of Origin | FR |
Currency | USD |
Dimensions | 8.82 in H x 1.77 in W x 4.96 in D |
EU RoHS Indicator | Y |
Gross Volume Per Pack | 132.00 |
Gross Volume per Pack Metric | 2163.08 |
Gross Volume UOM | CI |
Gross Volume UOM Metric | cm3 |
Gross Weight Per Pack | 2.8700 lb |
Gross Weight per Pack Metric | 1.30 |
Gross Weight UOM Metric | kg |
Harmonization Tariff Schedule Code | 8536304000 |
Height | 25.5000 in |
Height [Metric] | 25.5000 cm |
Item Group | 22396 |
Length | 15.3000 in |
Length [Metric] | 15.3000 cm |
Material Composition Declaration | https://checkaproduct.se.com/DistantRequestDispatcher.aspx?action=export&pid=640420&lang=en-us |
Motor Size | 110 to 240 VAC/VDC, 12 A, 1.7/2 W, 50/60 Hz, 3-Poles, 1NO-1NC |
Motor Type | Combination Motor Starters |
Mounting | DIN RAIL OR PANEL MOUNT |
Number Of Poles | 3 |
Power Supply | 110/240V |
Reset Type | MANUAL (AUTO WITH ACCESSORIES) |
Returnable | Y |
Series | LU2B |
Size | 126 MM,224 MM,45 MM |
Standard | UL LISTED - CSA CERTIFIED - CE MARKED |
Standards | ABS, ASEFA, ATEX, BV, CCC Certified, CSA C22.2 No. 14 Type E, DNV Certified, EN 60947-6-2, GL, GOST Certified, IEC 60947-6-2, LROS Certified, UL 508 |
Sub Brand | TESYS |
Substitute Product Catalog Number | GVAPB65 |
Type | Self-Protected |
UNSPSC | 39121521 |
UPC 11 | 78590120254 |
UPC 12 | 785901202547 |
Voltage Rating | 600 VAC |
Warranty Description | Contractual Warranty:18 months |
Width | 5.5000 in |
Width [Metric] | 5.5000 cm |
Stock Status | NONSTOCK |
Brand | Schneider Electric |
Manufacturer | Schneider Electric |
Color | 8.82 in H x 1.77 in W x 4.96 in D |
Specifications | 110 to 240 VAC/VDC, 12 A, 1.7/2 W, 50/60 Hz, 3-Poles, 1NO-1NC |
Suitable For Use With | Combination Motor Starters |
TESYS U SIMPLE MOTOR STARTER, REVERSING STARTER BASE |
REVERSING SIMPLE MOTOR STARTER. 120VAC CONTROL, WITH SIGNALING CONTACTS |
Suitability for isolation |
10 kA 500 V, 4 kA 690 V, 50 kA 230 V, 50 kA 440 V rated service breaking capacity |
1000 mA at 110 to 220 VDC I maximum while closing, 1000 mA at 110 to 240 VAC I maximum while closing typical current consumption |
150 ms with change of direction power circuit, 35 ms opening with LUCA, LUCB, LUCC, LUCD, LUCM control circuit, 70 ms closing with LUCA, LUCB, LUCC, LUCD control circuit, 75 ms closing with LUCM control circuit, 75 ms without change of direction power circuit operating time, 15 ms DC network duration of inrush phase |
15000000 cycles mechanical durability, 60 cycles/min operating rate, 6 kV conforming to IEC 60947-6-2 rated impulse withstand voltage, 600 V conforming to CSA C22.2 No 14, 600 V conforming to UL 508, 690 V conforming to IEC 60947-1 3 rated insulation voltage |
Control circuit: 7.08-10.62 lbf.in- with screwdriver 0.2 in flat, control circuit: 7.08-10.62 lbf.in - with screwdriver 0.2 in Philips no 1, power circuit: 16.81-22.12 lbf.in- with screwdriver 0.24 in flat, power circuit: 16.81-22.12 lbf.in - with screwdriver 0.24 in Philips no 2 tightening torque |
2 W for control circuit with LUCA, LUCB, LUCC, LUCD, 1.7 W for control circuit with LUCM heat dissipation |
IP20 front panel and wired terminals conforming to IEC 60947-1, IP20 other faces conforming to IEC 60947-1, IP40 front panel outside connection zone conforming to IEC 60947-1 IP degree of protection |
TH conforming to IEC 60068 protective treatment |
1 kV serial mode conforming to IEC 60947-6-2, 2 kV common mode conforming to IEC 60947-6-2 non-dissipating shock wave, 10 V conforming to IEC 61000-4-6 immunity to radio electric fields |
1/2 hp at 1 phase 120 VAC, 2 hp at 1 phase 240 VAC, 10 hp at 3 phase 575 VAC, 3 hp at 3 phase 208 VAC, 3 hp at 3 phase 220/240 VAC, 7.5 hp at 3 phase 460 VAC power rating |
-13 to 140 deg F with LUCM/-13 to 158 deg F with LUCA, LUCB, LUCC, LUCD |