Siemens 87DUD6FC Pump Control Panel, 220to 480VAC Coil, NEMA 3/3R Enclosure

Pump Control Panels
539290 MFG #: 87DUD6FC
Siemens
893.49000 / ea
  • Alternate Catalog Number: US2:87DUD6FC
  • Amperage Rating: 27 A
  • Application: Motor Controls
  • ARRA Compliant: C
  • Auxiliary Contact Rating: 10 A at 600 VAC (A600), 5 A at 600 VDC (P600)
  • Buy American Compliant: C
  • Catalog Number: 87DUD6FC
  • Connection: Screw
  • Connection Type: Box Lug/Threaded
  • Control Type: Hand-Off-Auto Selector Switch
  • Country of Origin: MX
  • Currency: USD
  • Dimensions: 29 in H x 20 in W x 8 in D
  • EU RoHS Indicator: C
  • Frequency Rating: 50/60 Hz
  • Gross Volume Per Pack: 1900.00
  • Gross Volume UOM: in
  • Gross Weight Per Pack: 47.0000 lb
  • Gross Weight per Pack Metric: 21.32
  • Gross Weight UOM Metric: kg
  • Harmonization Tariff Schedule Code: 8537109150
  • Motor Power: 5 hp
  • Mounting: Surface
  • Operating Cycles: 10000000 Cycles
  • Operating Temperature: -4 to 104 °F
  • Overload Relay: Solid State
  • Phase: 3 pH
  • Reset Type: Automatic/Manual/Remote
  • Returnable: Y
  • Size: SZ 1
  • Standard: UL;CSA
  • Standards: ARRA CompliantBuy American Act CompliantRoHS CompliantCSA CertifiedUL Listed
  • Sub Brand: Class 87
  • Timing: 19 to 29 ms On/10 to 24 ms Off
  • UNSPSC: 39121521
  • UPC 11: 66264353613
  • UPC 12: 662643536133
  • Voltage Rating: 600 VAC
  • Wattage: 8.6 W
  • Stock Status: NONSTOCK
  • Brand: Siemens
  • Manufacturer: Siemens
  • Coil Voltage: 220 to 480 VAC
  • Enclosure Type: NEMA 3/3R
  • Type: Class 87 Surface Mount
  • Number Of Poles: 3
SIEMENS 87DUD6FC MOTOR STARTER PANEL
QTY
  • Applications
  • Features
Motor Controls
NEMA rated
-22 to 149 deg F during storage
3NO contacts for main contacts
0NC contacts at contactor for auxiliary contacts, 1NO contacts at contactor for auxiliary contacts, 8 total auxiliary contacts maximum
220 to 480 VAC at 60 Hz/0 to 0 VAC 50 Hz
8.6 W holding power at AC minimum
218 VAC apparent pick up power of magnet coil, 25 VAC apparent holding power of magnet coil
0.85 to 1.1 VDC operating range factor control supply voltage rated value of magnet coil
50% drop-out voltage of magnet coil related to the input voltage
Overload protection, phase failure detection, phase unbalance, ground fault detection, test function, external reset overload relay function
5.5 to 22 A adjustable pick up value current of the current dependent overload release
3 sec trip time at phase loss maximum
Protective coating on printed circuit board
5 A at 600 VAC/1 A at 250 VDC operating current of auxiliary contacts of overload relay
Vertical surface mounting and installation
10 kA at 600 VAC (class H or K)/100 kA at 600 VAC (class R or J) design of the fuse link for short circuit protection of the main circuit required
0 hp at 200/208 VAC/0 hp at 220/230 VAC/10 hp at 460/480 VAC/10 hp at 575/600 VAC electrical ratings