or to view stock quantity and your pricing.
Steiner serves territories in Northern Illinois, Northwest Indiana and Southern Wisconsin. Please for assistance if outside our sales territory.
Schneider Electric 56230 RH10P Residual current protection relay, 220 to 240 VAC, Panel mount
Schneider Electric 56230 RH10P Residual current protection relay, 220 to 240 VAC, Panel mount
SKUPDW~13591870
MFGR #56230
Your Cost: $1,385.58/ea
List: Schneider Electric 56230, Residual current protection relay, RH10P, 220 to 240 VAC, Panel Mounting, 18-8 Stainless Steel, 2.83 in H x 2.83 in W x 3.07 in L x 3.07 in D Dimensions
Schneider Electric 56230, Residual current protection relay, RH10P, 220 to 240 VAC, Panel Mounting, 18-8 Stainless Steel, 2.83 in H x 2.83 in W x 3.07 in L x 3.07 in D Dimensions
Alternate Catalog Number 56230 ARRA Compliant N Buy American Compliant N Catalog Number 56230 Country of Origin FR Currency USD EU RoHS Indicator Y Gross Volume Per Pack 61.02 Gross Volume per Pack Metric 1000.00 Gross Volume UOM CI Gross Volume UOM Metric cm3 Gross Weight Per Pack 3.2500 lb Gross Weight per Pack Metric 325.00 Gross Weight UOM Metric g Harmonization Tariff Schedule Code 8536490080 Height 7.2000 in Height [Metric] 7.2000 cm Length 7.2000 in Length [Metric] 7.2000 cm Material Composition Declaration https://checkaproduct.se.com/DistantRequestDispatcher.aspx?action=export&pid=845562&lang=en-us Returnable N Type Residual current protection relay UNSPSC 39121601 Warranty Description Contractual Warranty:18 months Width 7.8000 in Width [Metric] 7.8000 cm Brand Square D™ Manufacturer Schneider Electric Panel or DIN-mount for easy installation Variety of sensors for a wide range of amperages from 65-3200A Models for most common power supply voltages up to 600 Vac Ground-fault fixed sensitivities from 30mA to 1A and adjustable sensitivities up to 30A Outputs may be used for protection via shunt trip of a circuit breaker or switch, or alarming via lights or annunciator for flexibility Compact size of relay and its sensor make it ideal for protection of OEM equipment as well as branch circuits Designed to meet UL 1053 standard for equipment protection Protection relay relay application Type A earth-leakage protection class Fixed residual earth-leakage sensitity adjustment type Fixed residual earth-leakage sensitity adjustment type 03 A earth-leakage sensitivity Instantaneous earth-leakage time delay TOA earth leakage current sensor A earth leakage current sensor L earth leakage current sensor current sensors compatibility 10 mA 12 V minimum load 1000 V - AC 50/60 Hz maximum) 1000 V - AC 400 Hz maximum) monitored distribution system TN-STTIT earthing system Manual reset reset Remote testLocal test function
content loaded
content loaded
content loaded
content loaded
- Attributes
- Documents & Resources
- Features
- Substitute Products
| Alternate Catalog Number | 56230 |
| ARRA Compliant | N |
| Buy American Compliant | N |
| Catalog Number | 56230 |
| Country of Origin | FR |
| Currency | USD |
| EU RoHS Indicator | Y |
| Gross Volume Per Pack | 61.02 |
| Gross Volume per Pack Metric | 1000.00 |
| Gross Volume UOM | CI |
| Gross Volume UOM Metric | cm3 |
| Gross Weight Per Pack | 3.2500 lb |
| Gross Weight per Pack Metric | 325.00 |
| Gross Weight UOM Metric | g |
| Harmonization Tariff Schedule Code | 8536490080 |
| Height | 7.2000 in |
| Height [Metric] | 7.2000 cm |
| Length | 7.2000 in |
| Length [Metric] | 7.2000 cm |
| Material Composition Declaration | https://checkaproduct.se.com/DistantRequestDispatcher.aspx?action=export&pid=845562&lang=en-us |
| Returnable | N |
| Type | Residual current protection relay |
| UNSPSC | 39121601 |
| Warranty Description | Contractual Warranty:18 months |
| Width | 7.8000 in |
| Width [Metric] | 7.8000 cm |
| Brand | Square D™ |
| Manufacturer | Schneider Electric |
| Panel or DIN-mount for easy installation |
| Variety of sensors for a wide range of amperages from 65-3200A |
| Models for most common power supply voltages up to 600 Vac |
| Ground-fault fixed sensitivities from 30mA to 1A and adjustable sensitivities up to 30A |
| Outputs may be used for protection via shunt trip of a circuit breaker or switch, or alarming via lights or annunciator for flexibility |
| Compact size of relay and its sensor make it ideal for protection of OEM equipment as well as branch circuits |
| Designed to meet UL 1053 standard for equipment protection |
| Protection relay relay application |
| Type A earth-leakage protection class |
| Fixed residual earth-leakage sensitity adjustment type |
| Fixed residual earth-leakage sensitity adjustment type |
| 03 A earth-leakage sensitivity |
| Instantaneous earth-leakage time delay |
| TOA earth leakage current sensor A earth leakage current sensor L earth leakage current sensor current sensors compatibility |
| 10 mA 12 V minimum load |
| 1000 V - AC 50/60 Hz maximum) 1000 V - AC 400 Hz maximum) monitored distribution system |
| TN-STTIT earthing system |
| Manual reset reset |
| Remote testLocal test function |