HPS (Hammond Power Solutions)
Hammond Power Solutions CRX0040BC, Line Reactor, Core and Coil, 480V, 30HP, 40 Amps, 3 Phase
Custom_Product_Images_Illustration
HPS (Hammond Power Solutions)
Hammond Power Solutions CRX0040BC, Line Reactor, Core and Coil, 480V, 30HP, 40 Amps, 3 Phase
SKU1087610
MFGR #CRX0040BC
Price Not Available
List: The new HPS Centurion® R reactor provides a unique blend of improved performance and reliability while reducing the product footprint. HPS Centurion® R reactors deliver protection for your motors and AC drives, while minimizing power system harmonics. They are available in standard ratings from 0.5 hp (373 W) to 1200 hp (895 kW), up to 600 V (690 V with de-rating) and are fully compliant with UL, CSA, CE, IEC, and NEMA standards. The efficient and cost effective HPS Centurion® R reactors are built to satisfy the power quality needs of demanding AC drive applications. HPS reactors are designed to address line-side issues associated with variable frequency drives. They attenuate voltage and current transients that can cause nuisance tripping of a drive. Reactors also minimize harmonic current levels within the drive supply circuit. When used on the output side of IGBT-based, PWM-type AC drives, HPS reactors reduce the motor operating temperature and audible noise by moderating line transients seen by the motor. The use of HPS reactors enhances the overall system performance, life expectancy, and efficiency of the motor.
The new HPS Centurion® R reactor provides a unique blend of improved performance and reliability while reducing the product footprint. HPS Centurion® R reactors deliver protection for your motors and AC drives, while minimizing power system harmonics. They are available in standard ratings from 0.5 hp (373 W) to 1200 hp (895 kW), up to 600 V (690 V with de-rating) and are fully compliant with UL, CSA, CE, IEC, and NEMA standards. The efficient and cost effective HPS Centurion® R reactors are built to satisfy the power quality needs of demanding AC drive applications. HPS reactors are designed to address line-side issues associated with variable frequency drives. They attenuate voltage and current transients that can cause nuisance tripping of a drive. Reactors also minimize harmonic current levels within the drive supply circuit. When used on the output side of IGBT-based, PWM-type AC drives, HPS reactors reduce the motor operating temperature and audible noise by moderating line transients seen by the motor. The use of HPS reactors enhances the overall system performance, life expectancy, and efficiency of the motor.
Amperage Rating 40 A Application Oil & Gas, Irrigation Fields, Wastewater, Food Processing, HVAC, Automotive ARRA Compliant C Buy American Compliant C Catalog Number CRX0040BC Country of Origin CAN Currency USD Depth 4.69 in Enclosure Core and Coil EU RoHS Indicator Y Frequency Rating 50/60 Hz Gross Weight Per Pack 12.5000 lb Gross Weight per Pack Metric 5.67 Gross Weight UOM Metric kg Harmonization Tariff Schedule Code 8504508000 Height 4.69 in Height [Metric] 11.9126 cm Horsepower 30 hp Impedance 0.05 Length 6.38 in Length [Metric] 16.2052 cm Material Iron Mounting Floor or Panel Mount Mounting Type Floor/Panel Noise Level Between 58dBA to 75 dBA Phase 3 Series CRX Standard CSA, UL, CE Standards ARRA CompliantBuy American Act CompliantRoHS CompliantUL 508 File No. E61431CSA C22.2 No. 47/C9 File No. LR3902CE MarkedIEC 61558-2-20:2000/61558-2-20 Sub Brand Reactors Type Reactors > Air Core > Centurion R series UNSPSC 39121015 UPC 11 80342311771 UPC 12 803423117719 Voltage Rating 480 VAC Width 7.12 in Width [Metric] 18.0848 cm Stock Status NONSTOCK Brand HPS (Hammond Power Solutions) Manufacturer Hammond Power Solutions Input Voltage 480 V Oil & Gas, Irrigation Fields, Wastewater, Food Processing, HVAC, Automotive Innovative design showcases a unique blend of performance and economy to protect your VFD, motor, capacitors and electrical system from harmonics, damage and nuisance tripping. The impedance of the reactors is accurately controlled by maintaining the core gaps in the flux path In some HP ranges, bobbins are used to provide exceptional mechanical strength and increase the product reliability Every reactor is vacuum pressure impregnated (VPI) with VT (vinyl-toluene) polyester resin to minimize audible noise Rugged steel enclosures with UL 50 ANSI 61 gray paint Finger proof terminal blocks are provided on rated currents of approximately below 65 A termination Terminal pads are supplied on approximately 65 A and above, terminal pads are brazed to ensure electrical integrity Mitigate nuisance tripping Extend the life of switching components and motors Reduce audible motor noise and motor operating temperature Mitigate the effect of long lead length Minimize harmonic distortion Reduce line notching Innovative design showcases a unique blend of performance and economy to protect your VFD, motor, capacitors and electrical system from harmonics, damage and nuisance tripping 50/60 Hz frequency rating Noise level between 58 to 75 dBA 0.05 Ohm impedance 0.94 mH inductance
content loaded
content loaded
content loaded
content loaded
content loaded
- Attributes
- Documents & Resources
- Applications
- Features
- Substitute Products
| Amperage Rating | 40 A |
| Application | Oil & Gas, Irrigation Fields, Wastewater, Food Processing, HVAC, Automotive |
| ARRA Compliant | C |
| Buy American Compliant | C |
| Catalog Number | CRX0040BC |
| Country of Origin | CAN |
| Currency | USD |
| Depth | 4.69 in |
| Enclosure | Core and Coil |
| EU RoHS Indicator | Y |
| Frequency Rating | 50/60 Hz |
| Gross Weight Per Pack | 12.5000 lb |
| Gross Weight per Pack Metric | 5.67 |
| Gross Weight UOM Metric | kg |
| Harmonization Tariff Schedule Code | 8504508000 |
| Height | 4.69 in |
| Height [Metric] | 11.9126 cm |
| Horsepower | 30 hp |
| Impedance | 0.05 |
| Length | 6.38 in |
| Length [Metric] | 16.2052 cm |
| Material | Iron |
| Mounting | Floor or Panel Mount |
| Mounting Type | Floor/Panel |
| Noise Level | Between 58dBA to 75 dBA |
| Phase | 3 |
| Series | CRX |
| Standard | CSA, UL, CE |
| Standards | ARRA CompliantBuy American Act CompliantRoHS CompliantUL 508 File No. E61431CSA C22.2 No. 47/C9 File No. LR3902CE MarkedIEC 61558-2-20:2000/61558-2-20 |
| Sub Brand | Reactors |
| Type | Reactors > Air Core > Centurion R series |
| UNSPSC | 39121015 |
| UPC 11 | 80342311771 |
| UPC 12 | 803423117719 |
| Voltage Rating | 480 VAC |
| Width | 7.12 in |
| Width [Metric] | 18.0848 cm |
| Stock Status | NONSTOCK |
| Brand | HPS (Hammond Power Solutions) |
| Manufacturer | Hammond Power Solutions |
| Input Voltage | 480 V |
| Oil & Gas, Irrigation Fields, Wastewater, Food Processing, HVAC, Automotive |
| Innovative design showcases a unique blend of performance and economy to protect your VFD, motor, capacitors and electrical system from harmonics, damage and nuisance tripping. |
| The impedance of the reactors is accurately controlled by maintaining the core gaps in the flux path |
| In some HP ranges, bobbins are used to provide exceptional mechanical strength and increase the product reliability |
| Every reactor is vacuum pressure impregnated (VPI) with VT (vinyl-toluene) polyester resin to minimize audible noise |
| Rugged steel enclosures with UL 50 ANSI 61 gray paint |
| Finger proof terminal blocks are provided on rated currents of approximately below 65 A termination |
| Terminal pads are supplied on approximately 65 A and above, terminal pads are brazed to ensure electrical integrity |
| Mitigate nuisance tripping |
| Extend the life of switching components and motors |
| Reduce audible motor noise and motor operating temperature |
| Mitigate the effect of long lead length |
| Minimize harmonic distortion |
| Reduce line notching |
| Innovative design showcases a unique blend of performance and economy to protect your VFD, motor, capacitors and electrical system from harmonics, damage and nuisance tripping |
| 50/60 Hz frequency rating |
| Noise level between 58 to 75 dBA |
| 0.05 Ohm impedance |
| 0.94 mH inductance |