  • Application: 22 KW, 3 PHASE 380...480 V,30 HP, 3 PHASE 380...480 V,ASYNCHRONOUS MOTORS-SYNCHRONOUS MOTORS,COMPLEX, HIGH-POWER MACHINES
  • ARRA Compliant: N
  • Buy American Compliant: N
  • Catalog Number: ATV71HD22N4
  • Control: +/- 0.01 OF NOMINAL SPEED IN CLOSED-LOOP MODE WITH ENCODER FEEDBACK 0.2 TN TO TN-+/- 10 OF NOMINAL SLIP WITHOUT SPEED FEEDBACK 0.2 TN TO TN in
  • Country of Origin: IN
  • Display: DRIVE VOLTAGE 1 LED RED)
  • Enclosure: IP20
  • Environmental Conditions: -10-50 A°C WITHOUT)
  • EU RoHS Indicator: Y
  • Gross Weight Per Pack: 63.9800 lb
  • Harmonization Tariff Schedule Code: 8504404000
  • Item Group: 22131
  • Material: IP20
  • Returnable: Y
  • Size: 230 MM,236 MM,420 MM
  • Sub Brand: ALTIVAR 71
  • Type: Variable speed drive
  • UNSPSC: 39122001
  • UPC 11: 78590160525
  • UPC 12: 785901605256
  • Stock Status: NONSTOCK
  • Brand: Schneider Electric
  • Manufacturer: Schneider Electric
Schneider Electric ATV71HD22N4 SPEED DRIVE, 30HP, 460V, ATV71,22kW,3 phases,3-Phase,3-Phase,400/480VAC,Altivar 71,Altivar 71,IP20,Modbus-CANopen,Modbus-CANopen,complex, high-power machines,variable speed drive
QTY
  • Applications
  • Features
22 KW, 3 PHASE 380...480 V,30 HP, 3 PHASE 380...480 V,ASYNCHRONOUS MOTORS-SYNCHRONOUS MOTORS,COMPLEX, HIGH-POWER MACHINES
ENA (ENERGY ADAPTATION) SYSTEM FOR UNBALANCED LOADS-FLUX VECTOR CONTROL (FVC) WITH SENSOR (CURRENT VECTOR)-VOLTAGE/FREQUENCY RATIO (2 OR 5 POINTS)-SENSORLESS FLUX VECTOR CONTROL (SFVC) (VOLTAGE OR CURRENT VECTOR),ADJUSTABLE PI REGULATOR,AGAINST EXCEEDING LIMIT SPEED DRIVE-SHORT-CIRCUIT BETWEEN MOTOR PHASES DRIVE-THERMAL PROTECTION DRIVE-MOTOR PHASE BREAK MOTOR-POWER REMOVAL MOTOR-THERMAL PROTECTION MOTOR-AGAINST INPUT PHASE LOSS DRIVE-BREAK ON THE CONTROL CIRCUIT DRIVE-INPUT PHASE BREAKS DRIVE-LINE SUPPLY OVERVOLTAGE DRIVE-LINE SUPPLY UNDERVOLTAGE DRIVE-OVERCURRENT BETWEEN OUTPUT PHASES AND EARTH DRIVE-OVERHEATING PROTECTION DRIVE-OVERVOLTAGES ON THE DC BUS DRIVE,INTERNAL SUPPLY FOR REFERENCE POTENTIOMETER (1 TO 10 KOHM) 10.5 V DC +/- 5 , <10 MA OVERLOAD AND SHORT-CIRCUIT PROTECTION-INTERNAL SUPPLY 24 V DC 21-27 V), <200 MA OVERLOAD AND SHORT-CIRCUIT PROTECTION,TERMINAL 2.5 MMA², AWG 14 AI1-/AI1+, AI2, AO1, R1A, R1B, R1C, R2A, R2B, LI1...LI6, PWR)-TERMINAL 50 MMA², AWG 1/0 L1/R, L2/S, L3/T, U/T1, V/T2, W/T3, PC/-, PO, PA/+, PA, PB)
Protection of motor and of drive
Exceptional performance, advanced functions
Altivar® 71 provides ingenious solutions for all your particular requirements
High performance applications
With heat sink assembly style
Integrated EMC filter
Constant torque
Graphic terminal
-10 to 50 deg C operating temperature
22 kW power rating
Graphic terminal
-10 to 50 deg C operating
22 kW power
3 phase