or to view stock quantity and your pricing.
Steiner serves territories in Northern Illinois, Northwest Indiana and Southern Wisconsin. Please for assistance if outside our sales territory.
Schneider Electric Altivar 212 ATV212HD15N4 Variable Speed Drive With Heat Sink, 480 VAC, 22.8/28.5 A, 20 hp, 9.65 in W
Custom_Product_Images_Illustration
Schneider Electric Altivar 212 ATV212HD15N4 Variable Speed Drive With Heat Sink, 480 VAC, 22.8/28.5 A, 20 hp, 9.65 in W
SKU664427
MFGR #ATV212HD15N4
Your Cost: $1,736.95/ea
List: Schneider Electric ATV212HD15N4 SPEEDDRIVE 380-480VAC 20HP,ATV212,15kW,3 phases,400/480 Vac 3-Phase,Altivar 212,Altivar 212,Maximum output voltage equal to input voltage 3-Phase,Modbus-METASYS N2-LonWorks-APOGEE FLN-BACnet,Modbus-METASYS N2-LonWorks-APOGEE FLN-BACnet,pumps and fans in HVAC,Open IP20,Size 4A,variable speed drive
Schneider Electric ATV212HD15N4 SPEEDDRIVE 380-480VAC 20HP,ATV212,15kW,3 phases,400/480 Vac 3-Phase,Altivar 212,Altivar 212,Maximum output voltage equal to input voltage 3-Phase,Modbus-METASYS N2-LonWorks-APOGEE FLN-BACnet,Modbus-METASYS N2-LonWorks-APOGEE FLN-BACnet,pumps and fans in HVAC,Open IP20,Size 4A,variable speed drive
Alternate Catalog Number ATV212HD15N4 Application Asynchronous motors;Pumps and fans in HVAC; ARRA Compliant N Buy American Compliant N Catalog Number ATV212HD15N4 Control +/- 10 OF NOMINAL SLIP 0.2 TN TO TN Country of Origin ID Currency USD Display for DC bus energized 1 LED (red) Display Type Analog Enclosure OPEN IP20 Enclosure Type Open/IP20/IP21/IP41 Environmental Conditions -10-40 A°C WITHOUT)-40-50 A°C WITH DERATING FACTOR),CLASSES 3C1 IEC 60721-3-3-CLASSES 3S2 IEC 60721-3-3 EU RoHS Indicator Y Gross Volume Per Pack 2111.96 Gross Volume per Pack Metric 34608.69 Gross Volume UOM CI Gross Volume UOM Metric cm3 Gross Weight Per Pack 25.4400 lb Gross Weight per Pack Metric 11.54 Gross Weight UOM Metric kg Harmonization Tariff Schedule Code 8504404000 Height 27.5000 in Height [Metric] 75.0000 cm Input Voltage 380...480 V - 15...10 % Item Group 22157 Length 30.0000 in Length [Metric] 80.0000 cm Material Composition Declaration https://checkaproduct.se.com/DistantRequestDispatcher.aspx?action=export&pid=61737718&lang=en-us Number Of Phases 3 Power Rating 625 W Returnable Y Size 190 MM,245 MM,330 MM in Standard IP21 Sub Brand ATV212 Substitute Product Catalog Number VW3A1101 Type 3-Phase UNSPSC 39122001 UPC 11 78590194408 UPC 12 785901944089 Warranty Description Contractual Warranty:18 months Width [Metric] 60.0000 cm Stock Status NONSTOCK Brand Schneider Electric Manufacturer Schneider Electric Amperage Rating 22.8/28.5 A Depth 7.48 in Horsepower 20 hp Voltage Rating 400/480 VAC Width 39.5000 in Asynchronous motors;Pumps and fans in HVAC; VIA, VIB, FM, FLA, FLB, FLC, RY, RC, F, R, RES terminal 2.5-2.5 mm² / AWG 14;L1/R, L2/S, L3/T terminal 25-25 mm² / AWG 3;Flux vector control without sensor, standard;voltage/frequency ratio, 2 points;voltage/frequency ratio, automatic IR compensation (U/f + automatic Uo);voltage/frequency ratio - Energy Saving, quadratic U/f;voltage/frequency ratio, 5 points;Overheating protection drive;line supply undervoltage drive;against input phase loss drive;thermal protection motor;motor phase break motor;with PTC probes motor;thermal power stage drive;short-circuit between motor phases drive;input phase breaks drive;overcurrent between output phases and earth drive;overvoltages on the DC bus drive;break on the control circuit drive;against exceeding limit speed drive;line supply overvoltage and undervoltage drive;Internal supply for reference potentiometer (1 to 10 kOhm) 10.5 V DC +/- 5 %, <10 A overload and short-circuit protection;internal supply 24 V DC 21-27 V), <200 A overload and short-circuit protection Centralized technical management Centered on user-friendliness Centered on protection APOGEE FLN, BACnet, LonWorks, METASYS N2, Modbus optional communication card Electrical between power and control insulation Maximum output voltage equal to input voltage 3-phase output 12 to 16 kHz with derating factor switching frequency 6 to 16 kHz adjustable switching frequency 1 to 10 speed range 625 W power dissipation 54420.42 Gal/hr air flow 54 dB noise level Electrical between power and control insulation 323 to 528 VAC supply voltage limits
content loaded
content loaded
content loaded
content loaded
content loaded
- Attributes
- Documents & Resources
- Applications
- Features
- Substitute Products
Alternate Catalog Number | ATV212HD15N4 |
Application | Asynchronous motors;Pumps and fans in HVAC; |
ARRA Compliant | N |
Buy American Compliant | N |
Catalog Number | ATV212HD15N4 |
Control | +/- 10 OF NOMINAL SLIP 0.2 TN TO TN |
Country of Origin | ID |
Currency | USD |
Display | for DC bus energized 1 LED (red) |
Display Type | Analog |
Enclosure | OPEN IP20 |
Enclosure Type | Open/IP20/IP21/IP41 |
Environmental Conditions | -10-40 A°C WITHOUT)-40-50 A°C WITH DERATING FACTOR),CLASSES 3C1 IEC 60721-3-3-CLASSES 3S2 IEC 60721-3-3 |
EU RoHS Indicator | Y |
Gross Volume Per Pack | 2111.96 |
Gross Volume per Pack Metric | 34608.69 |
Gross Volume UOM | CI |
Gross Volume UOM Metric | cm3 |
Gross Weight Per Pack | 25.4400 lb |
Gross Weight per Pack Metric | 11.54 |
Gross Weight UOM Metric | kg |
Harmonization Tariff Schedule Code | 8504404000 |
Height | 27.5000 in |
Height [Metric] | 75.0000 cm |
Input Voltage | 380...480 V - 15...10 % |
Item Group | 22157 |
Length | 30.0000 in |
Length [Metric] | 80.0000 cm |
Material Composition Declaration | https://checkaproduct.se.com/DistantRequestDispatcher.aspx?action=export&pid=61737718&lang=en-us |
Number Of Phases | 3 |
Power Rating | 625 W |
Returnable | Y |
Size | 190 MM,245 MM,330 MM in |
Standard | IP21 |
Sub Brand | ATV212 |
Substitute Product Catalog Number | VW3A1101 |
Type | 3-Phase |
UNSPSC | 39122001 |
UPC 11 | 78590194408 |
UPC 12 | 785901944089 |
Warranty Description | Contractual Warranty:18 months |
Width [Metric] | 60.0000 cm |
Stock Status | NONSTOCK |
Brand | Schneider Electric |
Manufacturer | Schneider Electric |
Amperage Rating | 22.8/28.5 A |
Depth | 7.48 in |
Horsepower | 20 hp |
Voltage Rating | 400/480 VAC |
Width | 39.5000 in |
Asynchronous motors;Pumps and fans in HVAC; |
VIA, VIB, FM, FLA, FLB, FLC, RY, RC, F, R, RES terminal 2.5-2.5 mm² / AWG 14;L1/R, L2/S, L3/T terminal 25-25 mm² / AWG 3;Flux vector control without sensor, standard;voltage/frequency ratio, 2 points;voltage/frequency ratio, automatic IR compensation (U/f + automatic Uo);voltage/frequency ratio - Energy Saving, quadratic U/f;voltage/frequency ratio, 5 points;Overheating protection drive;line supply undervoltage drive;against input phase loss drive;thermal protection motor;motor phase break motor;with PTC probes motor;thermal power stage drive;short-circuit between motor phases drive;input phase breaks drive;overcurrent between output phases and earth drive;overvoltages on the DC bus drive;break on the control circuit drive;against exceeding limit speed drive;line supply overvoltage and undervoltage drive;Internal supply for reference potentiometer (1 to 10 kOhm) 10.5 V DC +/- 5 %, <10 A overload and short-circuit protection;internal supply 24 V DC 21-27 V), <200 A overload and short-circuit protection |
Centralized technical management |
Centered on user-friendliness |
Centered on protection |
APOGEE FLN, BACnet, LonWorks, METASYS N2, Modbus optional communication card |
Electrical between power and control insulation |
Maximum output voltage equal to input voltage 3-phase output |
12 to 16 kHz with derating factor switching frequency |
6 to 16 kHz adjustable switching frequency |
1 to 10 speed range |
625 W power dissipation |
54420.42 Gal/hr air flow |
54 dB noise level |
Electrical between power and control insulation |
323 to 528 VAC supply voltage limits |