Bussmann® FRN-R-30 Non-Indicating Rejection Time Delay Fuse, 30 A, 250 VAC/125 VDC, 200 kA at 250 VAC, 20 kA at 125 VDC

Time Delay Fuses
4721 MFG #: FRN-R-30
Bussmann
9.83000 / ea
  • Alternate Catalog Number: FRN-R-30
  • Application: Ind Facilities & Factories - Facility: Safety and Security Systems
  • ARRA Compliant: C
  • Buy American Compliant: C
  • Catalog Number: FRN-R-30
  • Connection: Ferrule end x ferrule end
  • Country of Origin: MX
  • Currency: USD
  • Element: Dual
  • EU RoHS Indicator: C
  • Gross Weight Per Pack: 0.0500 lb
  • Gross Weight per Pack Metric: 0.88
  • Gross Weight UOM Metric: kg
  • Harmonization Tariff Schedule Code: 8536100040
  • Height: 0.81 in
  • Height [Metric]: 2.0574 cm
  • Length: 3.00 in
  • Length [Metric]: 7.6200 cm
  • Response Time: 10 S at 500%
  • Size: 0.56 In Diameter X 2.00 In Length
  • Standard: CE Marked
  • Standards: ARRA CompliantBuy American Act CompliantRoHS CompliantCE CertifiedUL 248-12UL JDDZUL File No. E4273CSA Class 1422-02CSA 53787C22.2 No. 248.12
  • Sub Brand: Bussmann Series
  • Type: Fuse
  • UNSPSC: 39121606
  • UPC 11: 05171210176
  • UPC 12: 051712101769
  • Width: 0.81 in
  • Width [Metric]: 2.0574 cm
  • Stock Status: NORMALLY STOCKED
  • Brand: Bussmann
  • Manufacturer: Eaton
  • Amperage Rating: 30 A
  • Class: RK-5
  • Interrupt Rating: 200 kAIC at 250 Vac20 kAIC at 125 Vdc
  • Voltage Rating: 250/125 VAC//VDC
Fusetron fuses are on average 23% more energy efficient than the next leading brand.
QTY
  • Applications
  • Features
Ind Facilities & Factories - Facility: Safety and Security Systems
Finger safe
Separate overload and short circuit elements provide time delay for sizing as close as 125% of motor FLA
2:1 selective coordination amp ratio (within the cooper Bussmann RK5 fuse family) prevents overcurrent events from opening upstream Fusetron™ fuses
Provides motor overload, ground fault and short circuit protection
Helps protect motors against burnout from overloads and single phasing on 3-phase systems
Simplifies and improves blackout prevention (selective coordination)
Dual element fuses can be applied in circuits subject to temporary motor overloads and surge currents to provide both high performance short circuit and overload protection
The overload element provides protection against low level overcurrent of overloads and will hold an overload which is five times greater than the ampere rating of the fuse for a minimum of ten seconds
200 kA (RMS symmetrical) at 250 VAC, 20 kA at 125 VDC interrupt rating
8 sec (minimum) at 500% of rated current time delay