Bussmann® LPN-RK-20SP Low-Peak™ LPN-RK Current Limiting Time Delay Fuse, 20 A, 250 VAC/125 VDC, 300/100 kA Interrupt, Class RK1

Class RK1 Fuses
5249 MFG #: LPN-RK-20SP
Bussmann
8.11000 / ea
  • Alternate Catalog Number: LPN-RK-20SP
  • Application: Ind Facilities & Factories - Facility: Safety and Security Systems
  • ARRA Compliant: C
  • Body Size: 0.56 in Dia x 2 in L
  • Buy American Compliant: C
  • Catalog Number: LPN-RK-20SP
  • Connection: Ferrule end x ferrule end
  • Country of Origin: MX
  • Currency: USD
  • Element: Dual
  • EU RoHS Indicator: C
  • Gross Weight Per Pack: 0.0500 lb
  • Gross Weight per Pack Metric: 0.23
  • Gross Weight UOM Metric: kg
  • Harmonization Tariff Schedule Code: 8536100040
  • Height: 0.60 in
  • Height [Metric]: 1.5240 cm
  • Length: 2.00 in
  • Length [Metric]: 5.0800 cm
  • Material: Melamine
  • Mounting Type: Holder
  • Response Time: 8 S at 500%
  • Series: LPN-RK
  • Size: 0.56 In Diameter X 2.00 In Length
  • Standard: CE Marked
  • Standards: ARRA CompliantBuy American Act CompliantRoHS CompliantUL ListedCSA C22.2CE Certified
  • Sub Brand: Bussmann Series
  • Terminal Type: Ferrule
  • Type: Fuse
  • UNSPSC: 39121606
  • UPC 11: 05171253834
  • UPC 12: 051712538343
  • Width: 0.60 in
  • Width [Metric]: 1.5240 cm
  • Stock Status: NONSTOCK
  • Brand: Bussmann
  • Manufacturer: Eaton
  • Amperage Rating: 20 A
  • Class: RK-1
  • Interrupt Rating: 300 kAIC at 250 Vac100 kAIC at 125 Vdc
  • Voltage Rating: 250/125 VAC//VDC
Ultimate protection Class RK1 dual element, current- limiting time-delay fuses available with optional open fuse indication. Time-delay - 10 seconds (minimum) at 500% of rated current (8 seconds for 0 - 30 A sizes).
QTY
  • Applications
  • Features
Ind Facilities & Factories - Facility: Safety and Security Systems
Non-indicating, High in-rush current motor protection
Fast short circuit protection and dual-element, time-delay performance provide ultimate protection
Easy selective coordination with all low peak fuses using simple 2:1 ampacity ratio
Current-limiting for maximum short circuit protection
No damage Type "2" protection for IEC and NEMA motor starters when properly sized
High inrush current motor protection
Time-delay that permits 130% FLA sizing for back-up motor protection
Provides protection against single-phase motor damage
Low watt loss power consumption
Electrically isolated end caps for added safety
Reduces existing fuse inventory by up to 33% when upgrading to low peak fuses