O-Z/Gedney EYAX-75 3/4 IN HOR/VERT SEALING

Conduit Sealing Fittings
499371 MFG #: EYAX75
O-Z/Gedney
34.95000 / ea
  • Application: For Rigid Conduit Or IMC
  • ARRA Compliant: N
  • Buy American Compliant: N
  • Catalog Number: EYAX75
  • Connection: Tapered FNPT
  • Country of Origin: MX
  • Currency: USD
  • Dimensions: 1-3/4 in Dia x 4-5/16 in L
  • EU RoHS Indicator: N
  • Gross Weight Per Pack: 1.8500 lb
  • Gross Weight per Pack Metric: 0.84
  • Gross Weight UOM Metric: kg
  • Height: 0.86 in
  • Height [Metric]: 21.8440 mm
  • Length: 6.80 in
  • Length [Metric]: 17.2720 cm
  • Standards: UL File No. E34997CSA 009795 for Wet LocationsClass I Division 1/2 Group A/B/C/D, Class I Zone 1/2 Group IIA, IIB and IIC, Class II Division 1/2 Group E/F/G, Class IIIUL 886CSA C22.2 No. 30NEC 500-503/505Mil-F-28675
  • Type: Type EYAX Vertical/Horizontal Sealing Fitting
  • UNSPSC: 39121311
  • UPC 11: 78312611393
  • UPC 12: 783126113938
  • Width: 5.20 in
  • Width [Metric]: 13.2080 cm
  • Stock Status: NONSTOCK
  • Brand: O-Z/Gedney
  • Manufacturer: O-Z/Gedney
  • Finish: Zinc Electroplated
  • Material: Malleable Iron
  • Size: 3/4 in
  • Suitable For Use With: IMC/Rigid Metal Conduit
OZ-Gedney Type EYAX Vertical/Horizontal Sealing Fitting, Size: 3/4 IN, Malleable Iron, Finish: Zinc Electroplated, Connection: Tapered FNPT, Dimensions: 1-3/4 IN Body Diameter X 4-5/16 IN Overall Length, 1-3/8 IN Turning Radius, 2.25 OZ Sealing Co
QTY
  • Applications
  • Features
For Rigid Conduit Or IMC
To seal vertical or horizontal conduit runs where 40 PCT conductor fill is required; To minimize the passage of gases and vapors and prevent the passage of flames from one portion of the electrical system to another through the conduit; Explosion proof, dust-ignition proof; Use with type EYC sealing compound and type EYF fiber
To seal vertical or horizontal conduit runs where 40 PCT conductor fill is required
To minimize the passage of gases and vapors and prevent the passage of flames from one portion of the electrical system to another through the conduit
Use with type EYC sealing compound and type EYF fiber
Prevent passage of gases, vapors or flames from one portion of conduit system to another
Restrict any explosion to the sealed off enclosure
Prevent pressure piling within conduit system
Required in class I, division 1 and 2 locations within 18 in of enclosures containing apparatus that may cause arcs, sparks or high temperatures
Required in class I, division 1 and 2 locations where 2 in or larger conduit enters enclosure, fitting housing terminals, splices or taps
Required in class I, division 1 and 2 locations at the boundary where conduit leaves classified location
Required in class I, division 1 and 2 locations where two or more enclosures are connected by 36 in or less conduit, seal must be located within 18 in of either enclosure
Required where cables (which exceed rate of gas or vapor transmission permitted for seals) are used in class I, division 2 locations
Smooth, rounded integral bushing in each hub to protect conductor insulation
Accurately tapped, tapered threads for tight, rigid joints and ground continuity
Removable nipple in male sealing fitting may be used interchangeably in top or bottom hub
Allow up to 40% conduit fill in compliance with the national electrical code