or to view stock quantity and your pricing.
Steiner serves territories in Northern Illinois, Northwest Indiana and Southern Wisconsin. Please for assistance if outside our sales territory.
Siemens P2440L1125CU SpeedFax™ PL Series Main Lug Load Center, 120/240 VAC, 125 A, 22 kA Interrupt
Custom_Product_Images_Illustration
Siemens P2440L1125CU SpeedFax™ PL Series Main Lug Load Center, 120/240 VAC, 125 A, 22 kA Interrupt
SKU618904
MFGR #P2440L1125CU
Your Cost: $88.86/ea
List: SIEMENS P2440L1125CU 40CT 125A LD-CTR
SIEMENS P2440L1125CU 40CT 125A LD-CTR
Application RESIDENTIALANDLIGHTCOMMERCIALELECTRICDISTRIBUTION ARRA Compliant C Breaker Type MBK125A Bus Rating 125 A Buy American Compliant C Catalog Number P2440L1125CU Country of Origin MX Currency USD Enclosure Type1 Enclosure Box Size 24 in H x 14-1/4 in W x 3-7/8 in D Enclosure Type NEMA 1 EU RoHS Indicator C Gross Weight Per Pack 26.0000 lb Gross Weight per Pack Metric 11.79 Gross Weight UOM Metric kg Harmonization Tariff Schedule Code 8537109150 Height 26.38 in Height [Metric] 66.9925 cm Length 16.00 in Length [Metric] 40.6400 cm Mounting FLUSH/SURFACE Number of Circuits 40 Number Of Feeders 40 Number Of Spaces 24 Phase 1 Returnable N Series PL Series Standards ARRA CompliantBuy American Act CompliantRoHS CompliantUL File No. E10703 Sub Brand UL Type PLSERIESASSEMBLEDLOADCENTER UNSPSC 39121101 UPC 11 04089264976 UPC 12 040892649765 Width 5.75 in Width [Metric] 14.6050 cm Wiring Configuration 3-Wire Stock Status NORMALLY STOCKED Brand Siemens Manufacturer Siemens Amperage Rating 125 A Interrupt Rating 22 kA Voltage Rating 120/240 VAC RESIDENTIALANDLIGHTCOMMERCIALELECTRICDISTRIBUTION GREYTRIM Invertible for bottom feed application All devices are provided with 2 factory installed ground bars Combination head screw on the neutrals, ground, trim, upper pan, and bond screw provide installation flexibility A rigid, sturdy base pan provides the ruggedness required for the most harsh applications All devices convertible from main lug to main breaker and vice versa Mounting tabs on the trim hold it in place on the load center, freeing up both hands to drive the trim screws The prepositioned bond screw eliminates bond strap/screw assemblies, and reduces the risk of losing components in the field The patented INSTA-WIRE neutral/ground system allows for faster installation because screws are backed out, ready for wire insertion The visible neutral and grounds system aids in the insertion of conductors Dual neutrals on all configurations Indoor enclosure Copper busbar MBK100A/MBK125A breaker Combination mounting
content loaded
content loaded
content loaded
content loaded
content loaded
- Attributes
- Documents & Resources
- Applications
- Features
- Media
- Substitute Products
Application | RESIDENTIALANDLIGHTCOMMERCIALELECTRICDISTRIBUTION |
ARRA Compliant | C |
Breaker Type | MBK125A |
Bus Rating | 125 A |
Buy American Compliant | C |
Catalog Number | P2440L1125CU |
Country of Origin | MX |
Currency | USD |
Enclosure | Type1 |
Enclosure Box Size | 24 in H x 14-1/4 in W x 3-7/8 in D |
Enclosure Type | NEMA 1 |
EU RoHS Indicator | C |
Gross Weight Per Pack | 26.0000 lb |
Gross Weight per Pack Metric | 11.79 |
Gross Weight UOM Metric | kg |
Harmonization Tariff Schedule Code | 8537109150 |
Height | 26.38 in |
Height [Metric] | 66.9925 cm |
Length | 16.00 in |
Length [Metric] | 40.6400 cm |
Mounting | FLUSH/SURFACE |
Number of Circuits | 40 |
Number Of Feeders | 40 |
Number Of Spaces | 24 |
Phase | 1 |
Returnable | N |
Series | PL Series |
Standards | ARRA CompliantBuy American Act CompliantRoHS CompliantUL File No. E10703 |
Sub Brand | UL |
Type | PLSERIESASSEMBLEDLOADCENTER |
UNSPSC | 39121101 |
UPC 11 | 04089264976 |
UPC 12 | 040892649765 |
Width | 5.75 in |
Width [Metric] | 14.6050 cm |
Wiring Configuration | 3-Wire |
Stock Status | NORMALLY STOCKED |
Brand | Siemens |
Manufacturer | Siemens |
Amperage Rating | 125 A |
Interrupt Rating | 22 kA |
Voltage Rating | 120/240 VAC |
RESIDENTIALANDLIGHTCOMMERCIALELECTRICDISTRIBUTION |
GREYTRIM |
Invertible for bottom feed application |
All devices are provided with 2 factory installed ground bars |
Combination head screw on the neutrals, ground, trim, upper pan, and bond screw provide installation flexibility |
A rigid, sturdy base pan provides the ruggedness required for the most harsh applications |
All devices convertible from main lug to main breaker and vice versa |
Mounting tabs on the trim hold it in place on the load center, freeing up both hands to drive the trim screws |
The prepositioned bond screw eliminates bond strap/screw assemblies, and reduces the risk of losing components in the field |
The patented INSTA-WIRE neutral/ground system allows for faster installation because screws are backed out, ready for wire insertion |
The visible neutral and grounds system aids in the insertion of conductors |
Dual neutrals on all configurations |
Indoor enclosure |
Copper busbar |
MBK100A/MBK125A breaker |
Combination mounting |