or to view stock quantity and your pricing.
Steiner serves territories in Northern Illinois, Northwest Indiana and Southern Wisconsin. Please for assistance if outside our sales territory.
Square D™
Schneider Electric GB2DB12, 415 VAC, 6 A
Square D™
Schneider Electric GB2DB12, 415 VAC, 6 A
SKU1309387
MFGR #GB2DB12
Your Cost: $136.02/ea
Schneider Electric GB2DB12, 415 VAC, 6 A, 50/60 Hz Frequency, connector 1 0.00 to 0.01 sq. in. (0.75 to 6 sq. mm) solid without cable end/connector 2 0.00 to 0.01 sq. in. (0.75 to 4 sq. mm) solid without cable end/connector 1 0.00 to 0.01 sq. in. (0.75 to 4 sq. mm) flexible with cable end/connector 2 0.00 to 0.00 sq. in. (0.75 to 2.5 sq. mm) flexible with cable end Connection, IP20 Enclosure, -4 to 140 deg F, 2.91 in H x 1.18 in W x 2.76 in D Dimensions
Schneider Electric GB2DB12, 415 VAC, 6 A, 50/60 Hz Frequency, connector 1 0.00 to 0.01 sq. in. (0.75 to 6 sq. mm) solid without cable end/connector 2 0.00 to 0.01 sq. in. (0.75 to 4 sq. mm) solid without cable end/connector 1 0.00 to 0.01 sq. in. (0.75 to 4 sq. mm) flexible with cable end/connector 2 0.00 to 0.00 sq. in. (0.75 to 2.5 sq. mm) flexible with cable end Connection, IP20 Enclosure, -4 to 140 deg F, 2.91 in H x 1.18 in W x 2.76 in D Dimensions
Alternate Catalog Number GB2DB12 Application For protection of DC loads up to 6A/48V DC-13 with a breaking capacity Icu 1, For the protection of industrial equipment control circuits, For 8000 cycles ARRA Compliant N Buy American Compliant N Catalog Number GB2DB12 Country of Origin FR Currency USD EU RoHS Indicator Y Gross Volume Per Pack 42.00 Gross Volume per Pack Metric 688.25 Gross Volume UOM CI Gross Volume UOM Metric cm3 Gross Weight Per Pack 244.7100 lb Gross Weight per Pack Metric 111.00 Gross Weight UOM Metric g Harmonization Tariff Schedule Code 8536200020 Height 3.1000 in Height [Metric] 3.1000 cm Item Group 22631 Length 7.5000 in Length [Metric] 7.5000 cm Material Composition Declaration https://checkaproduct.se.com/DistantRequestDispatcher.aspx?action=export&pid=6969198&lang=en-us Returnable N UNSPSC 39121633 Warranty Description Contractual Warranty:18 months Width 7.4000 in Width [Metric] 7.4000 cm Stock Status NONSTOCK Brand Square D™ Manufacturer Schneider Electric For protection of DC loads up to 6A/48V DC-13 with a breaking capacity Icu 1, For the protection of industrial equipment control circuits, For 8000 cycles TeSys GB2 thermal-magnetic circuit breakers are available in various ratings and with different breaking capacities Compliance with standards: IEC 947-1, 947-2 1-pole + neutral (GB2 CD) 2-pole (GB2 DB) Magnetic tripping threshold set between 12 to 16 In (withstands current peaks generated by many industrial components.) 2 ratings available: 0.5 and 1 A 1-pole version Magnetic tripping threshold set between 5 and 7 In 15 mm wide for 1-pole AC/DC network type AC/DC network type 75 % 110 V AC 50/60 Hz IEC 60947-275 % 230/240 V AC 50/60 Hz IEC 60947-275 % 400/415 V AC 50/60 Hz IEC 60947-2 ics rated service short-circuit breaking capacity 83 A magnetic tripping current HorizontalVertical mounting position 4 kV IEC 60947-2 uimp rated impulse withstand voltage 8000 cycles mechanical durability Shocks 22 Gn for 20 ms IEC 60068-2-27Vibrations 5 Gn, 5 to 110 Hz IEC 60068-2-6 mechanical robustness 4 9 mm pitches TC protective treatment 1760 deg F (960 deg C) IEC 60695-2-1 fire resistance
content loaded
content loaded
content loaded
content loaded
content loaded
- Attributes
- Documents & Resources
- Applications
- Features
- Substitute Products
| Alternate Catalog Number | GB2DB12 |
| Application | For protection of DC loads up to 6A/48V DC-13 with a breaking capacity Icu 1, For the protection of industrial equipment control circuits, For 8000 cycles |
| ARRA Compliant | N |
| Buy American Compliant | N |
| Catalog Number | GB2DB12 |
| Country of Origin | FR |
| Currency | USD |
| EU RoHS Indicator | Y |
| Gross Volume Per Pack | 42.00 |
| Gross Volume per Pack Metric | 688.25 |
| Gross Volume UOM | CI |
| Gross Volume UOM Metric | cm3 |
| Gross Weight Per Pack | 244.7100 lb |
| Gross Weight per Pack Metric | 111.00 |
| Gross Weight UOM Metric | g |
| Harmonization Tariff Schedule Code | 8536200020 |
| Height | 3.1000 in |
| Height [Metric] | 3.1000 cm |
| Item Group | 22631 |
| Length | 7.5000 in |
| Length [Metric] | 7.5000 cm |
| Material Composition Declaration | https://checkaproduct.se.com/DistantRequestDispatcher.aspx?action=export&pid=6969198&lang=en-us |
| Returnable | N |
| UNSPSC | 39121633 |
| Warranty Description | Contractual Warranty:18 months |
| Width | 7.4000 in |
| Width [Metric] | 7.4000 cm |
| Stock Status | NONSTOCK |
| Brand | Square D™ |
| Manufacturer | Schneider Electric |
| For protection of DC loads up to 6A/48V DC-13 with a breaking capacity Icu 1, For the protection of industrial equipment control circuits, For 8000 cycles |
| TeSys GB2 thermal-magnetic circuit breakers are available in various ratings and with different breaking capacities |
| Compliance with standards: IEC 947-1, 947-2 |
| 1-pole + neutral (GB2 CD) |
| 2-pole (GB2 DB) |
| Magnetic tripping threshold set between 12 to 16 In (withstands current peaks generated by many industrial components.) |
| 2 ratings available: 0.5 and 1 A |
| 1-pole version |
| Magnetic tripping threshold set between 5 and 7 In |
| 15 mm wide for 1-pole |
| AC/DC network type |
| AC/DC network type |
| 75 % 110 V AC 50/60 Hz IEC 60947-275 % 230/240 V AC 50/60 Hz IEC 60947-275 % 400/415 V AC 50/60 Hz IEC 60947-2 ics rated service short-circuit breaking capacity |
| 83 A magnetic tripping current |
| HorizontalVertical mounting position |
| 4 kV IEC 60947-2 uimp rated impulse withstand voltage |
| 8000 cycles mechanical durability |
| Shocks 22 Gn for 20 ms IEC 60068-2-27Vibrations 5 Gn, 5 to 110 Hz IEC 60068-2-6 mechanical robustness |
| 4 9 mm pitches |
| TC protective treatment |
| 1760 deg F (960 deg C) IEC 60695-2-1 fire resistance |