Siemens 3RV2 Motor Protection Circuit Breaker, 690 VAC, 2.2 to 3.2 A, 10 kA Interrupt, 3 Poles, Magnetic Trip
Custom_Product_Images_Illustration
Siemens
Siemens 3RV2 Motor Protection Circuit Breaker, 690 VAC, 2.2 to 3.2 A, 10 kA Interrupt, 3 Poles, Magnetic Trip
SKU936030
MFGR #3RV24111DA10
Your Cost: $145.83/ea
List: Siemens 3RV24111DA10 MSP S00 FOR XFRMR 2.2-3.2A SCREW
Siemens 3RV24111DA10 MSP S00 FOR XFRMR 2.2-3.2A SCREW
Alternate Catalog Number 3RV2411-1DA10 Application 3RV2 circuit breaker ARRA Compliant C Buy American Compliant C Catalog Number 3RV24111DA10 Connection screw-type terminals Connection Type Screw Country of Origin DE Currency USD Dimensions 97 mm H x 45 mm W x 97 mm D Enclosure Type IP20 Environmental Conditions 80 -50 C EU RoHS Indicator C Frame S00 Frequency Rating 50/60 Hz Gross Volume Per Pack 121.38 Gross Volume UOM in Gross Weight Per Pack 0.7650 lb Gross Weight per Pack Metric 0.35 Gross Weight UOM Metric kg Harmonization Tariff Schedule Code 8536308000 Height 4.0000 in Height [Metric] 10.1600 cm Length 4.5000 in Length [Metric] 11.4300 cm Mounting Type DIN Rail/Snap-On/Threaded Number Of Poles 3 Operating Temperature 60 to -20 °C Phase 3 pH Power Rating 2.2 kW Replaced Catalog Number 3RV1421-1DA10 Returnable Y Series 3RV2 Standards CCC CertifiedCSA CertifiedUL ListedEAC ApprovedCE CertifiedVDE ApprovedRoHS CompliantABS ApprovedBureau Veritas CertifiedLloyd's RegisteredPRS CertifiedRINA CertifiedRMRS ApprovedDNV-GL Approved Sub Brand Sirius Temperature Rating -20 to 60 °C Trip Range 2.2 to 3.2 A, 65 A Type 3RV2 circuit breaker UNSPSC 39121601 UPC 11 66264392229 UPC 12 662643922295 Width 2.5500 in Width [Metric] 6.4770 cm Wire Size 18 to 14 AWG, 12 AWG Stock Status NONSTOCK Brand Siemens Manufacturer Siemens Amperage Rating 3.2 A Interrupt Rating 10 kA Trip Type Thermomagnetic Voltage Rating 690 VAC 3RV2 circuit breaker Can optionally be fed from the top or from below Minimization of energy losses through optimization of the bimetal trip units Reduction of inherent power loss Less heating of the control cabinet Smaller control cabinet air conditioners can be used 3RV2 motor starter protectors/circuit breakers are suitable for operation in IT systems (IT networks) 550 W at 230 VAC, 1100 W at 400 VAC, 1500 W at 500 VAC, 2200 W at 690 VAC 100 kA at 240 VAC, 100 kA at 400 VAC, 100 kA at 500 VAC, 10 kA at 690 VAC 2.2 to 3.2 A thermal overload release, 65 A instantaneous overcurrent release Without auxiliary switch
content loaded
content loaded
content loaded
content loaded
content loaded
- Attributes
- Documents & Resources
- Applications
- Features
- Substitute Products
Alternate Catalog Number | 3RV2411-1DA10 |
Application | 3RV2 circuit breaker |
ARRA Compliant | C |
Buy American Compliant | C |
Catalog Number | 3RV24111DA10 |
Connection | screw-type terminals |
Connection Type | Screw |
Country of Origin | DE |
Currency | USD |
Dimensions | 97 mm H x 45 mm W x 97 mm D |
Enclosure Type | IP20 |
Environmental Conditions | 80 -50 C |
EU RoHS Indicator | C |
Frame | S00 |
Frequency Rating | 50/60 Hz |
Gross Volume Per Pack | 121.38 |
Gross Volume UOM | in |
Gross Weight Per Pack | 0.7650 lb |
Gross Weight per Pack Metric | 0.35 |
Gross Weight UOM Metric | kg |
Harmonization Tariff Schedule Code | 8536308000 |
Height | 4.0000 in |
Height [Metric] | 10.1600 cm |
Length | 4.5000 in |
Length [Metric] | 11.4300 cm |
Mounting Type | DIN Rail/Snap-On/Threaded |
Number Of Poles | 3 |
Operating Temperature | 60 to -20 °C |
Phase | 3 pH |
Power Rating | 2.2 kW |
Replaced Catalog Number | 3RV1421-1DA10 |
Returnable | Y |
Series | 3RV2 |
Standards | CCC CertifiedCSA CertifiedUL ListedEAC ApprovedCE CertifiedVDE ApprovedRoHS CompliantABS ApprovedBureau Veritas CertifiedLloyd's RegisteredPRS CertifiedRINA CertifiedRMRS ApprovedDNV-GL Approved |
Sub Brand | Sirius |
Temperature Rating | -20 to 60 °C |
Trip Range | 2.2 to 3.2 A, 65 A |
Type | 3RV2 circuit breaker |
UNSPSC | 39121601 |
UPC 11 | 66264392229 |
UPC 12 | 662643922295 |
Width | 2.5500 in |
Width [Metric] | 6.4770 cm |
Wire Size | 18 to 14 AWG, 12 AWG |
Stock Status | NONSTOCK |
Brand | Siemens |
Manufacturer | Siemens |
Amperage Rating | 3.2 A |
Interrupt Rating | 10 kA |
Trip Type | Thermomagnetic |
Voltage Rating | 690 VAC |
3RV2 circuit breaker |
Can optionally be fed from the top or from below |
Minimization of energy losses through optimization of the bimetal trip units |
Reduction of inherent power loss |
Less heating of the control cabinet |
Smaller control cabinet air conditioners can be used |
3RV2 motor starter protectors/circuit breakers are suitable for operation in IT systems (IT networks) |
550 W at 230 VAC, 1100 W at 400 VAC, 1500 W at 500 VAC, 2200 W at 690 VAC |
100 kA at 240 VAC, 100 kA at 400 VAC, 100 kA at 500 VAC, 10 kA at 690 VAC |
2.2 to 3.2 A thermal overload release, 65 A instantaneous overcurrent release |
Without auxiliary switch |