loading content
or to view stock quantity and your pricing.

Steiner serves territories in Northern Illinois, Northwest Indiana and Southern Wisconsin. Please for assistance if outside our sales territory.

Siemens

Sentron™ HPD63F160 Thermal Magnetic Trip Breaker Frame, 600 VAC/250 to 500 VDC, 1600 A, 3 Poles

Custom_Product_Images_Illustration

Siemens

Sentron™ HPD63F160 Thermal Magnetic Trip Breaker Frame, 600 VAC/250 to 500 VDC, 1600 A, 3 Poles

SKU744923

MFGR #HPD63F160

Your Cost: $24,610.07/ea
List: $34,241.00 /ea
Sentron™ Breaker Frame, Thermal Magnetic Trip, 600 VAC/250 to 500 VDC, 1600 A, 3 Poles, Line/Load Side Lug Terminal, 50 kA IR Rating, For Use With: Low Voltage PD Frame Molded Case Circuit Breaker, 50/60 Hz, 40 deg C Operating Temperature, 5000 to 10000 Trip Range, 300 to 600 kcmil Cu/Al Wire Range, High IC Rating, Varying Enclosure and Actuator, 10 in L x 12 in W x 19 in H
Sentron™ Breaker Frame, Thermal Magnetic Trip, 600 VAC/250 to 500 VDC, 1600 A, 3 Poles, Line/Load Side Lug Terminal, 50 kA IR Rating, For Use With: Low Voltage PD Frame Molded Case Circuit Breaker, 50/60 Hz, 40 deg C Operating Temperature, 5000 to 10000 Trip Range, 300 to 600 kcmil Cu/Al Wire Range, High IC Rating, Varying Enclosure and Actuator, 10 in L x 12 in W x 19 in H

Actuator

Varying

Alternate Catalog Number

US2:HPD63F160

Application

Frame Only

ARRA Compliant

C

Auxiliary Contacts

N/A

Buy American Compliant

C

Catalog Number

HPD63F160

Connection

N/A

Country of Origin

MX

Currency

USD

Dimensions

10 in L x 12 in W x 19 in H

Enclosure

Varying

Environmental Conditions

N/A

EU RoHS Indicator

C

Frame

PD

Frequency Rating

50/60 Hz

Gross Volume Per Pack

2280.01

Gross Volume UOM

in

Gross Weight Per Pack

54.1000 lb

Gross Weight per Pack Metric

24.54

Gross Weight UOM Metric

kg

Harmonization Tariff Schedule Code

8536200020

Height

10.0000 in

Height [Metric]

25.4000 cm

Interrupt Rating

50KAIC

IR Rating

50 kA

Length

19.0000 in

Length [Metric]

48.2600 cm

Load Rating

N/A

Number Of Poles

3

Operating Temperature

40C

Returnable

Y

Specifications

50/60 Hz, 40 deg C Operating Temperature, 5000 to 10000 Trip Range, 300 to 600 kcmil Cu/Al Wire Range, High IC Rating, Varying Enclosure and Actuator

Standard

HACR

Standards

UL 489IEC 60947-2, HACR RatedRoHS CompliantARRA CompliantBuy American Act Compliant

Sub Brand

SENTRON

Suitable For Use With

Low Voltage PD Frame Molded Case Circuit Breaker

Trip Range

5000-10000

Trip Type

THERMAL-MAGNETIC

Type

Thermal Magnetic Trip

UNSPSC

39121601

UPC 11

78364322619

UPC 12

783643226197

Width

12.0000 in

Width [Metric]

30.4800 cm

Stock Status

NONSTOCK

Brand

Siemens

Manufacturer

Siemens

Amperage Rating

1600 A

Material

N/A

Terminal Type

Line/Load Side Lug

Voltage Rating

600 VAC/250 to 500 VDC