or to view stock quantity and your pricing.
Steiner serves territories in Northern Illinois, Northwest Indiana and Southern Wisconsin. Please for assistance if outside our sales territory.
Siemens
Siemens SIMOTION 6AU14322AA000AA0 Drive-Based Controller Extension, 6 Inputs, 4 Outputs, 3.5 mA
Custom_Product_Images_Illustration
Siemens
Siemens SIMOTION 6AU14322AA000AA0 Drive-Based Controller Extension, 6 Inputs, 4 Outputs, 3.5 mA
SKU709269
MFGR #6AU14322AA000AA0
Your Cost: $1,987.14/ea
List: Siemens SIMOTION Controller Extension, Drive-Based, 6 Input, 4 Output, 3.5 mA, 20.4 to 28.8 VDC, 1.6 A, 7 W, 0 to 55 deg C, 380 mm H x 25 mm W x 270 mm D
Siemens SIMOTION Controller Extension, Drive-Based, 6 Input, 4 Output, 3.5 mA, 20.4 to 28.8 VDC, 1.6 A, 7 W, 0 to 55 deg C, 380 mm H x 25 mm W x 270 mm D
Alternate Catalog Number 6AU1432-2AA00-0AA0 Amperage Rating 1.6 A ARRA Compliant C Buy American Compliant C Catalog Number 6AU14322AA000AA0 Country of Origin DE Currency USD Dimensions 380 mm H x 25 mm W x 270 mm D EU RoHS Indicator C Gross Volume Per Pack 484.47 Gross Volume UOM in Gross Weight Per Pack 6.9450 lb Gross Weight per Pack Metric 3.15 Gross Weight UOM Metric kg Harmonization Tariff Schedule Code 8504907500 Height 1.5700 in Height [Metric] 3.9878 cm Length 22.2000 in Length [Metric] 56.3880 cm Power Rating 7 W Returnable Y Series SIMOTION Standards ARRA CompliantBuy American Act CompliantRoHS CompliantcULus Listed Temperature Rating 0 to 55 °C Type Drive Based UNSPSC 26111527 UPC 11 04089272864 UPC 12 040892728644 Voltage Rating 20.4 to 28.8 VDC Width 13.9000 in Width [Metric] 35.3060 cm Stock Status NONSTOCK Brand Siemens Manufacturer Siemens Number of Inputs 6 Number of Outputs 4 Resolution 1 Signal Range 3.5 mA 6 servo, 6 vector, 12 V/F maximum number of axes for integrated drive control 4 DRIVE-CLiQ interfaces 300 mA with no load on inputs/outputs, no 24 V supply via DRIVE-CLiQ interface consumed current/typical, 1.6 A making current type -25 to 55 deg C long term storage and -40 to 70 deg C transport 5 to 95% relative humidity during operation Wert fehlt without condensation, tested according to IEC 60068-2-38 620 to 1060 hPa air pressure IP20 degree of protection 24 VDC rated value, 15 to 30 VDC for signal 1, -3 to 5 VDC for signal 0 DC input voltage Electrical isolation 3.5 mA current consumption for 1 signal level 50 u signal 0 to 1, 150 u signal 1 to 0 input delay time 5 u measuring input/reproducibility, 1 u measuring input/resolution 24 VDC rated value, 20.4 to 28.8 VDC load voltage 500 mA current carrying capacity for each maximum output, 2 mA maximum leakage current 150 u signal 0 to 1 type, 400 u signal 0 to 1 maximum, 75 u signal 1 to 0, type, 100 u signal 1 to 0, maximum output delay 4 kHz maximum resistive load, 2 Hz inductive load, 11 Hz lamp load switching frequency of the outputs Short circuit protection
content loaded
content loaded
content loaded
content loaded
- Attributes
- Documents & Resources
- Features
- Substitute Products
Alternate Catalog Number | 6AU1432-2AA00-0AA0 |
Amperage Rating | 1.6 A |
ARRA Compliant | C |
Buy American Compliant | C |
Catalog Number | 6AU14322AA000AA0 |
Country of Origin | DE |
Currency | USD |
Dimensions | 380 mm H x 25 mm W x 270 mm D |
EU RoHS Indicator | C |
Gross Volume Per Pack | 484.47 |
Gross Volume UOM | in |
Gross Weight Per Pack | 6.9450 lb |
Gross Weight per Pack Metric | 3.15 |
Gross Weight UOM Metric | kg |
Harmonization Tariff Schedule Code | 8504907500 |
Height | 1.5700 in |
Height [Metric] | 3.9878 cm |
Length | 22.2000 in |
Length [Metric] | 56.3880 cm |
Power Rating | 7 W |
Returnable | Y |
Series | SIMOTION |
Standards | ARRA CompliantBuy American Act CompliantRoHS CompliantcULus Listed |
Temperature Rating | 0 to 55 °C |
Type | Drive Based |
UNSPSC | 26111527 |
UPC 11 | 04089272864 |
UPC 12 | 040892728644 |
Voltage Rating | 20.4 to 28.8 VDC |
Width | 13.9000 in |
Width [Metric] | 35.3060 cm |
Stock Status | NONSTOCK |
Brand | Siemens |
Manufacturer | Siemens |
Number of Inputs | 6 |
Number of Outputs | 4 |
Resolution | 1 |
Signal Range | 3.5 mA |
6 servo, 6 vector, 12 V/F maximum number of axes for integrated drive control |
4 DRIVE-CLiQ interfaces |
300 mA with no load on inputs/outputs, no 24 V supply via DRIVE-CLiQ interface consumed current/typical, 1.6 A making current type |
-25 to 55 deg C long term storage and -40 to 70 deg C transport |
5 to 95% relative humidity during operation |
Wert fehlt without condensation, tested according to IEC 60068-2-38 |
620 to 1060 hPa air pressure |
IP20 degree of protection |
24 VDC rated value, 15 to 30 VDC for signal 1, -3 to 5 VDC for signal 0 DC input voltage |
Electrical isolation |
3.5 mA current consumption for 1 signal level |
50 u signal 0 to 1, 150 u signal 1 to 0 input delay time |
5 u measuring input/reproducibility, 1 u measuring input/resolution |
24 VDC rated value, 20.4 to 28.8 VDC load voltage |
500 mA current carrying capacity for each maximum output, 2 mA maximum leakage current |
150 u signal 0 to 1 type, 400 u signal 0 to 1 maximum, 75 u signal 1 to 0, type, 100 u signal 1 to 0, maximum output delay |
4 kHz maximum resistive load, 2 Hz inductive load, 11 Hz lamp load switching frequency of the outputs |
Short circuit protection |