SolaHD DT651H14S Ventilated Drive Isolation Transformer, 460 VAC Delta Primary, 460Y/266 VAC Secondary, 14 kVA, 60 Hz

Drive Isolation Transformers
438719 MFG #: DT651H14S
SolaHD™
1519.30000 / ea
  • Application: SCR Variable Speed Drives
  • ARRA Compliant: Y
  • Buy American Compliant: Y
  • Catalog Number: DT651H14S
  • Country of Origin: US
  • Currency: USD
  • Dimensions: 14 in L x 18 in W x 23 in H
  • Enclosure: Nema 3R with weather shield
  • Enclosure Type: NEMA 3R
  • EU RoHS Indicator: Y
  • Gross Weight Per Pack: 215.0000 lb
  • Gross Weight per Pack Metric: 97.52
  • Gross Weight UOM Metric: kg
  • Height: 23.00 in
  • Height [Metric]: 58.4200 cm
  • KVA Rating: 11
  • Length: 13.60 in
  • Length [Metric]: 34.5440 cm
  • Mounting Type: Floor
  • NEMA Frame Size: NEMA 3R
  • Number Of Phases: 3
  • Standard: cULus Listed: E77014, UL 506, CSA C22.2 No. 66, Listed E25872, UL 1561
  • Standards: ARRA CompliantBuy American Act CompliantRoHS CompliantcULus File No. E77014UL 506 File No. E25872UL 1561 File No. E25872CSA C22.2 No. 66
  • Type: Drive Isolation Transformers: 7.5-440 kVA, Three Phase
  • UNSPSC: 39121029
  • UPC 11: 78347240016
  • UPC 12: 783472400164
  • Width: 17.90 in
  • Width [Metric]: 45.4660 cm
  • Stock Status: NONSTOCK
  • Brand: SolaHD™
  • Manufacturer: Emerson
  • Frequency Rating: 60 Hz
  • Phase: 3 pH
  • Power Rating: 14 kVA
  • Primary Voltage: 460 Delta
  • Secondary Voltage: 460Y/266
SolaHD Drive Isolation Transformer, Ventilated, 460 VAC Delta Primary, 460Y/266 VAC Secondary, 14 kVA, 60 Hz, 3 Phase, 1, 5% FCAN/1, 5% FCBN Taps, Floor Mount, NEMA 3R, 23 in H x 18 in W x 14 in D
QTY
  • Applications
  • Features
SCR Variable Speed Drives
Isolation minimizes load disturbances caused by the SCR drive. Taps on all units for adjustments to incoming source voltage. Full capacity secondary neutral as required by the NEC.
Taps on all units for adjustments to incoming source voltage
Full capacity secondary neutral as required by the national electric code
Shielding attenuates line to ground noise
Isolation minimizes load disturbances caused by the SCR drive
A transformer is needed to magnetically isolate the incoming line from the motor drive
The transformer must also provide a voltage change to match the required voltage of the SCR drive
Standard designs are delta primary and wye secondary to match the common power sources required in most 3-phase rectifier circuits
Designed to handle the mechanical stresses, voltage demands and harmonics associated with SCR applications
Designed to handle the mechanical stresses, voltage demands and harmonics associated with SCR applications