SolaHD DT651H118S Ventilated Drive Isolation Transformer, 460 VAC Delta Primary, 460Y/266 VAC Secondary, 118 kVA, 60 Hz

Drive Isolation Transformers
280911 MFG #: DT651H118S
SolaHD™
5044.30000 / ea
  • Application: For SCR (Silicon Control Rectifier) variable speed motor drive applications
  • ARRA Compliant: Y
  • Buy American Compliant: Y
  • Catalog Number: DT651H118S
  • Country of Origin: US
  • Currency: USD
  • Dimensions: 22 in L x 28 in W x 34 in H
  • Enclosure: Nema 3R with weather shield
  • Enclosure Type: NEMA 3R
  • EU RoHS Indicator: Y
  • Gross Weight Per Pack: 819.0000 lb
  • Gross Weight per Pack Metric: 371.50
  • Gross Weight UOM Metric: kg
  • Height: 51.00 in
  • Height [Metric]: 129.5400 cm
  • KVA Rating: 93
  • Length: 40.00 in
  • Length [Metric]: 101.6000 cm
  • Mounting Type: Floor
  • NEMA Frame Size: NEMA 3R
  • Number Of Phases: 3
  • Standard: cULus: Listed: E77014, UL 506, CSA C22.2 No. 66, UL Listed: E25872, UL 1561
  • Standards: ARRA CompliantBuy American Act CompliantRoHS CompliantcULus File No. E77014UL 1561 File No. E25872UL 506 File No. E25872CSA C22.2 No. 66
  • Type: Ventilated
  • UNSPSC: 39121029
  • UPC 11: 78347240141
  • UPC 12: 783472401413
  • Width: 40.00 in
  • Width [Metric]: 101.6000 cm
  • Stock Status: NONSTOCK
  • Brand: SolaHD™
  • Manufacturer: Emerson
  • Frequency Rating: 60 Hz
  • Phase: 3 pH
  • Power Rating: 118 kVA
  • Primary Voltage: 460 V
  • Secondary Voltage: 460Y/260 VAC V
SolaHD Drive Isolation Transformer, Ventilated, 460 VAC Delta Primary, 460Y/266 VAC Secondary, 118 kVA, 60 Hz, 3 Phase, Floor Mount, NEMA 3R, 44 in H x 33 in W x 21 in D
QTY
  • Applications
  • Features
For SCR (Silicon Control Rectifier) variable speed motor drive applications
10 Year Warranty, Shielding attenuates line to ground noise, Taps on all units for adjustment to incoming source voltage, Full capacity secondary neutral as required by NEC, NEAM 3R with optional Weather Shield
Taps on all units for adjustments to incoming source voltage
Full capacity secondary neutral as required by the national electric code
Shielding attenuates line to ground noise
Isolation minimizes load disturbances caused by the SCR drive
A transformer is needed to magnetically isolate the incoming line from the motor drive
The transformer must also provide a voltage change to match the required voltage of the SCR drive
Standard designs are delta primary and wye secondary to match the common power sources required in most 3-phase rectifier circuits
Designed to handle the mechanical stresses, voltage demands and harmonics associated with SCR applications
Designed to handle the mechanical stresses, voltage demands and harmonics associated with SCR applications