Banner Engineering SM2A312DQD Mani-Beam® 312 Photoelectric Sensor, Rectangular Shape, 380 mm Sensing, Infrared Sensing Beam

Photoelectric Diffuse Mode Sensors
64556 MFG #: SM2A312DQD
Banner
127.00000 / ea
  • Connection Type: Quick-Disconnect
  • Country of Origin: USA
  • Enclosure Type: NEMA 1/2/3/3S/4/4X/12/13/IP67
  • Environmental Conditions: 90% at 50 deg C
  • Frequency Rating: 50/60 Hz
  • Light Source: LED
  • Operating Temperature: -20 to 70 deg C
  • Output Type: Switch
  • Response Time: 8 ms
  • Sensing Beam: Infrared
  • Sensing Method: Diffuse
  • Sensing Range: 380 mm
  • Series: 312
  • Shape: Rectangular
  • Size: 84.8 mm L x 12 mm W x 33.3 mm H
  • Standards/Approvals: CE Marked, cCSAus Certified, cULus Listed , RoHS Complaint
  • Stock Status: Normally Stocked
  • UOM: lb
  • Voltage Rating: 24/240 VAC
  • Weight: 1
  • Brand Name: Banner
  • Manufacturer: Banner Engineering
Banner Engineering Mani-Beam® Photoelectric Sensor, Series: 312, Rectangular, Diffuse Sensing Method, 380 mm Sensing Range, Infrared Sensing Beam, 8 ms Response, Switch Output, 24/240 VAC, 50/60 Hz, Quick-Disconnect, LED Light Source, 84.8 mm L x 12 mm W x 33.3 mm H, NEMA 1/2/3/3S/4/4X/12/13/IP67, -20 to 70 deg C Operating, Environmental Conditions: 90% at 50 deg C
QTY
  • Features
Protected against transient voltages, false pulse on power-up
Controls are located on the rear panel of the sensor and are protected by a gasketed, clear acrylic cover
Totally encapsulated, O-ring sealing, stainless steel screws construction
Overload conditions can destroy ac MINI-BEAM sensors. Directly wiring sensor without load series, across hot and neutral will damage sensor (except emitter models)
Low-voltage use requires careful analysis of the load to determine if the sensors leakage current or on-state voltage will interfere with proper operation of the load
The false-pulse protection feature may cause momentary drop-out of the load when the sensor is wired in series or parallel with mechanical switch contacts
Controls are located on rear panel of sensor and protected by a gasketed, clear acrylic cove
5 mA minimum load current, 300 mA to 50 deg C, 100 mA to 70 deg C maximum steady-state load capability, 3 A for 1 sec (non-repetitive), 10 A For 1 cycle (non-repetitive) inrush capability
Less than or equal to 5 V at 300 mA load and less than or equal to 10 V at 15 mA load on-state voltage drop
Self-contained diffuse mode photoelectric sensor
Less than 1.7 mA off-state output leakage
8 ms on/off response time
880 nm infrared LED sensing beam
Acrylic lens, 90 percent at 50 deg C (non-condensing) relative humidity
3-pin micro-style quick disconnect connection
Thermoplastic reinforced VALOX enclosure
Light/dark operate, solid-state AC switch output
18 mm barrel diameter
Self-Contained
Rectangular with M18 barrel housing style; Protected against transient voltages, false pulse on power-up; Controls are located on the rear panel of the sensor and are protected by a gasketed, clear acrylic cover; Totally encapsulated, o-ring sealing, stainless steel screws construction; Overload conditions can destroy ac MINI-BEAM sensors. Directly wiring sensor without load series, across hot and neutral will damage sensor (except emitter models); Low-voltage use requires careful analysis of the load to determine if the sensor's leakage current or on-state voltage will interfere with proper operation of the load; The false-pulse protection feature may cause momentary drop-out of the load when the sensor is wired in series or parallel with mechanical switch contacts; Controls are located on rear panel of sensor and protected by a gasketed, clear acrylic co