Siemens 3RV2021-4DA10 Type 3RV2 Motor Protection Circuit Breaker, 690 VAC, 25 A, 4 kA Interrupt, 3 Poles

Motor Protection Circuit Breakers
661115 MFG #: 3RV20214DA10
Siemens
194.29000 / ea
  • Alternate Catalog Number: 3RV2021-4DA10
  • Application: Used as Manual Motor Controller and in Group Installation
  • ARRA Compliant: C
  • Buy American Compliant: C
  • Catalog Number: 3RV20214DA10
  • Connection: screw-type terminals
  • Connection Type: Screw
  • Country of Origin: DE
  • Currency: USD
  • Dimensions: 97 mm H x 45 mm W x 97 mm D
  • Enclosure Type: IP20
  • Environmental Conditions: 80 -50 C
  • EU RoHS Indicator: C
  • Frame: S0
  • Frequency Rating: 50/60 Hz
  • Gross Volume Per Pack: 33.20
  • Gross Volume UOM: in
  • Gross Weight Per Pack: 0.8150 lb
  • Gross Weight per Pack Metric: 0.37
  • Gross Weight UOM Metric: kg
  • Harmonization Tariff Schedule Code: 8536304000
  • Height: 4.00 in
  • Height [Metric]: 10.1600 cm
  • Length: 4.15 in
  • Length [Metric]: 10.5410 cm
  • Mounting Type: DIN Rail/Snap-On/Threaded
  • Operating Temperature: 60 to -20 °C
  • Phase: 3
  • Power Rating: 22 kW
  • Replaced Catalog Number: 3RV1021-4DA10
  • Returnable: Y
  • Standard: CE / UL / CSA / CCC
  • Standards: CCC CertifiedCSA CertifiedUL ListedEAC ApprovedEX ATEXIECEx CertifiedCE CertifiedVDE ApprovedRoHS CompliantABS ApprovedBureau Veritas CertifiedLloyd's RegisteredPRS CertifiedRINA CertifiedRMRS ApprovedDNV-GL ApprovedEN 60715
  • Sub Brand: Sirius
  • Temperature Rating: -20 to 60 °C
  • Trip Range: 18 to 25 A, 325 A
  • Type: 3RV2 circuit breaker
  • UNSPSC: 39121601
  • UPC 11: 66264392442
  • UPC 12: 662643924428
  • Width: 2.00 in
  • Width [Metric]: 5.0800 cm
  • Wire Size: 16 to 12 AWG, 14 to 8 AWG
  • Stock Status: NORMALLY STOCKED
  • Brand: Siemens
  • Manufacturer: Siemens
  • Amperage Rating: 25 A
  • Interrupt Rating: 4 kA
  • Trip Type: Thermomagnetic
  • Voltage Rating: 690 VAC
  • Number Of Poles: 3
Siemens 3RV20214DA10 MSP S0 20-25A SCREW
QTY
  • Applications
  • Features
Used as Manual Motor Controller and in Group Installation
MSP?s are UL approved as Self Protected Combination Motor Controllers
Minimization of energy losses through optimization of the bimetal trip units
Reduction of inherent power loss
Less heating of the control cabinet
Smaller control cabinet air conditioners can be used
3RV2 motor starter protectors/circuit breakers are suitable for operation in IT systems (IT networks)
5500 W at 230 VAC, 11000 W at 400 VAC, 15000 W at 500 VAC, 22000 W at 690 VAC
100 kA at 240 VAC, 55 kA at 400 VAC, 10 kA at 500 VAC, 4 kA at 690 VAC
18 to 25 A thermal overload release, 325 A instantaneous overcurrent release
Without auxiliary switch