Weidmuller ESX10-TB-101 Electric Circuit Breaker, 24 VDC, 10 A, 1 Poles, Electronic Trip

Equipment Protection Circuit Breakers
PDW~10121184 MFG #: 6720005330
Weidmuller
0.00000 / ea
  • Actuator Type: Slide Switch
  • Auxiliary Contact Rating: SC/SO-SI
  • Catalog Number: 6720005330
  • Connection Type: Threaded
  • Dimensions: 80 mm H x 12.5 mm W x 83 mm D
  • Enclosure Type: IP20
  • Gross Weight Per Pack: 0.1400 lb
  • Mounting Type: DIN Rail
  • Series: ESX10-TB-101
  • Standards: UL 2367File No E-306740UL 508File No E-322549UL 1604File No E-320024CSA Certified
  • Temperature Rating: 0 to 50 deg C Temperature
  • Trip Range: 100 ms to 3 sec
  • Stock Status: NONSTOCK
  • Brand: Weidmuller
  • Manufacturer: Weidmuller, USA
  • Amperage Rating: 10 A
  • Trip Type: ELECTRONIC
  • Voltage Rating: 24 VDC
  • Number Of Poles: 1
Electronic circuit protection type ESX10-T is designed to ensure selective disconnection of 24 VDC load systems. 24 VDC power supplies, which are widely used in industry today, will shut down the output in the event of an overload with the result that one faulty load in the system can lead to complete disconnection of all loads. Through selective disconnection the ESX10-T responds much faster to overload or short circuit conditions than the switch-mode power supply. This is achieved by active current limitation. The ESX10-T limits the highest possible current to 1.3 to 1.8 times the selected rated current of the circuit protector. Thus it is possible to switch on capacitive loads of up to 20000 uF, but they are disconnected only in the event of an overload or short circuit. For optimal alignment with the characteristics of the application the current rating of the ESX10-T can be selected in fixed values from 0.5 to 12 A. Failure and status indication are provided by a multicolor LED and an integral short-circuit-proof status output or a relay signal contact. Remote operation is possible by means of a remote reset signal or a remote ON/OFF control signal. The manual ON/OFF button allows separate actuation and reset of individual load circuits.
QTY
  • Features
Selective load protection, electronic trip characteristics
Active current limitation for safe connection of capacitive loads up-to 20000 micro-F and on overload/short circuit
Reliable overload disconnection with 1.1 x in plus, even with long load lines or small cable cross sections
Manual ON/OFF button (S1)
Control input IN+ for remote ON/OFF signal (option)
Electronic reset input RE (option)
Clear status and failure indication through LED, status output SF or Si contact F
Integral fail-safe element adjusted to current rating
Width per unit only 12.5 mm
Ease of wiring through busbar LINE+ and 0 V as well as signal bars and bridges
Hazardous area approved - class 1 division 2, zone 2, ATEX zone 2
-20 to 70 deg C storage temperature
Typically 20 to 30 mA closed current in on condition, depending on signal output
Power-MOSFET switching load output (high side switch)
Typically 3 sec trip time for electronic disconnection
Internal temperature monitoring with electronic disconnection
Typically 0.5 sec starting delay after every switch-on and after applying Ub
Electronic disconnection of load output
External free-wheeling diode recommended with inductive load
32 vdc maximum dielectric strength